BP-Net: Cuff-less and non-invasive blood pressure estimation via a generic deep convolutional architecture

被引:7
作者
Zabihi, Soheil [1 ]
Rahimian, Elahe [2 ]
Marefat, Fatemeh [3 ]
Asif, Amir [1 ]
Mohseni, Pedram [3 ]
Mohammadi, Arash [2 ]
机构
[1] Concordia Univ, Elect & Comp Engn, 1455 Maisonneuve Blv W,EV 009-187, Montreal, PQ H3G 1M8, Canada
[2] Concordia Univ, Concordia Inst Informat Syst Engn, Montreal, PQ, Canada
[3] Case Western Reserve Univ, Elect Comp & Syst Engn, Cleveland, OH USA
基金
加拿大自然科学与工程研究理事会;
关键词
Continuous blood pressure (BP) estimation; Deep learning; Electrocardiograph (ECG); Photoplethysmograph (PPG); WAVE-FORM; KALMAN FILTER; TIME;
D O I
10.1016/j.bspc.2022.103850
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
Objective: The paper focuses on development of robust and accurate processing solutions for continuous and cuff-less blood pressure (BP) monitoring. In this regard, a robust deep learning-based framework is proposed for computation of low latency and continuous upper and lower bounds on the systolic and diastolic BP.Methods: Referred to as the BP-Net, the proposed framework is a novel convolutional architecture that provides longer effective memory while achieving superior performance due to incorporation of casual dialated convolutions and residual connections. To utilize the real potential of deep learning in extraction of intrinsic features (deep features) and enhance the long-term robustness, the BP-Net uses raw Electrocardiograph (ECG) and Photoplethysmograph (PPG) signals without extraction of any form of hand-crafted features as it is common in existing solutions. Results: By capitalizing on the fact that datasets used in recent literature are not unified and properly defined, a benchmark dataset is constructed from the MIMIC-I and MIMIC-III databases obtained from PhysioNet. The proposed BP-Net is evaluated based on this benchmark dataset demonstrating promising performance and shows superior generalizable capacity. Conclusion: The proposed BP-Net architecture is more accurate than canonical recurrent networks and enhances the long-term robustness of the BP estimation task. Significance: The proposed BP-Net architecture addresses key drawbacks of existing BP estimation solutions, i.e., relying heavily on extraction of hand-crafted features, such as pulse arrival time (PAT), and; Lack of robustness. Finally, the constructed BP-Net dataset provides a unified base for evaluation and comparison of deep learning-based BP estimation algorithms.
引用
收藏
页数:13
相关论文
共 30 条
  • [21] Non-invasive arterial blood pressure measurement and SpO2 estimation using PPG signal: a deep learning framework
    Yan Chu
    Kaichen Tang
    Yu-Chun Hsu
    Tongtong Huang
    Dulin Wang
    Wentao Li
    Sean I. Savitz
    Xiaoqian Jiang
    Shayan Shams
    BMC Medical Informatics and Decision Making, 23
  • [22] Estimating Continuous Blood Pressure from Photoplethysmogram Signals for Non-invasive Devices by Convolutional Neural Network
    Dong, Bui An
    Hoang, Phan Minh
    2023 IEEE STATISTICAL SIGNAL PROCESSING WORKSHOP, SSP, 2023, : 671 - 675
  • [23] Cascade forest regression algorithm for non-invasive blood pressure estimation using PPG signals
    Zhang, Gengjia
    Shin, Siho
    Jung, Jaehyo
    APPLIED SOFT COMPUTING, 2023, 144
  • [24] Non-Invasive Blood Pressure Estimation from Photoplethysmography Signals using Artificial Neural Networks
    Bersano, Nicolas
    Sanson, Horacio
    2018 20TH INTERNATIONAL CONFERENCE ON ADVANCED COMMUNICATION TECHNOLOGY (ICACT), 2018, : 29 - 35
  • [25] A non-invasive continuous cuffless blood pressure estimation using dynamic Recurrent Neural Networks
    Senturk, Umit
    Polat, Kemal
    Yucedag, Ibrahim
    APPLIED ACOUSTICS, 2020, 170
  • [26] A Deep Sparse Capsule Network for Non-Invasive Blood Glucose Level Estimation Using a PPG Sensor
    Chellamani, Narmatha
    Albelwi, Saleh Ali
    Shanmuganathan, Manimurugan
    Amirthalingam, Palanisamy
    Alharbi, Emad Muteb
    Alatawi, Hibah Qasem Salman
    Prabahar, Kousalya
    Aljabri, Jawhara Bader
    Paul, Anand
    SENSORS, 2025, 25 (06)
  • [27] Assessment of Non-Invasive Blood Pressure Prediction from PPG and rPPG Signals Using Deep Learning
    Schrumpf, Fabian
    Frenzel, Patrick
    Aust, Christoph
    Osterhoff, Georg
    Fuchs, Mirco
    SENSORS, 2021, 21 (18)
  • [28] Continuous non-invasive arterial blood pressure monitoring with photoplethysmography via SE-MSResUNet network
    Ma, Ke
    Zou, Lili
    Yang, Feng
    Zhan, Chang'an A.
    Gong, Yao
    Huang, Dequn
    BIOMEDICAL SIGNAL PROCESSING AND CONTROL, 2024, 90
  • [29] Subject-wise model generalization through pooling and patching for regression: Application on non-invasive systolic blood pressure estimation
    Mohammed, Hazem
    Wang, Kai
    Wu, Hao
    Wang, Guoxing
    COMPUTERS IN BIOLOGY AND MEDICINE, 2022, 151
  • [30] Deep Learning-Based Model for Non-invasive Hemoglobin Estimation via Body Parts Images: A Retrospective Analysis and a Prospective Emergency Department Study
    Lin, En-Ting
    Lu, Shao-Chi
    Liu, An-Sheng
    Ko, Chia-Hsin
    Huang, Chien-Hua
    Tsai, Chu-Lin
    Fu, Li-Chen
    JOURNAL OF IMAGING INFORMATICS IN MEDICINE, 2024, : 775 - 792