BP-Net: Cuff-less and non-invasive blood pressure estimation via a generic deep convolutional architecture

被引:7
作者
Zabihi, Soheil [1 ]
Rahimian, Elahe [2 ]
Marefat, Fatemeh [3 ]
Asif, Amir [1 ]
Mohseni, Pedram [3 ]
Mohammadi, Arash [2 ]
机构
[1] Concordia Univ, Elect & Comp Engn, 1455 Maisonneuve Blv W,EV 009-187, Montreal, PQ H3G 1M8, Canada
[2] Concordia Univ, Concordia Inst Informat Syst Engn, Montreal, PQ, Canada
[3] Case Western Reserve Univ, Elect Comp & Syst Engn, Cleveland, OH USA
基金
加拿大自然科学与工程研究理事会;
关键词
Continuous blood pressure (BP) estimation; Deep learning; Electrocardiograph (ECG); Photoplethysmograph (PPG); WAVE-FORM; KALMAN FILTER; TIME;
D O I
10.1016/j.bspc.2022.103850
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
Objective: The paper focuses on development of robust and accurate processing solutions for continuous and cuff-less blood pressure (BP) monitoring. In this regard, a robust deep learning-based framework is proposed for computation of low latency and continuous upper and lower bounds on the systolic and diastolic BP.Methods: Referred to as the BP-Net, the proposed framework is a novel convolutional architecture that provides longer effective memory while achieving superior performance due to incorporation of casual dialated convolutions and residual connections. To utilize the real potential of deep learning in extraction of intrinsic features (deep features) and enhance the long-term robustness, the BP-Net uses raw Electrocardiograph (ECG) and Photoplethysmograph (PPG) signals without extraction of any form of hand-crafted features as it is common in existing solutions. Results: By capitalizing on the fact that datasets used in recent literature are not unified and properly defined, a benchmark dataset is constructed from the MIMIC-I and MIMIC-III databases obtained from PhysioNet. The proposed BP-Net is evaluated based on this benchmark dataset demonstrating promising performance and shows superior generalizable capacity. Conclusion: The proposed BP-Net architecture is more accurate than canonical recurrent networks and enhances the long-term robustness of the BP estimation task. Significance: The proposed BP-Net architecture addresses key drawbacks of existing BP estimation solutions, i.e., relying heavily on extraction of hand-crafted features, such as pulse arrival time (PAT), and; Lack of robustness. Finally, the constructed BP-Net dataset provides a unified base for evaluation and comparison of deep learning-based BP estimation algorithms.
引用
收藏
页数:13
相关论文
共 30 条
  • [1] Non-invasive cuff-less blood pressure estimation using a hybrid deep learning model
    Sen Yang
    Yaping Zhang
    Siu-Yeung Cho
    Ricardo Correia
    Stephen P. Morgan
    Optical and Quantum Electronics, 2021, 53
  • [2] Non-invasive cuff-less blood pressure estimation using a hybrid deep learning model
    Yang, Sen
    Zhang, Yaping
    Cho, Siu-Yeung
    Correia, Ricardo
    Morgan, Stephen P.
    OPTICAL AND QUANTUM ELECTRONICS, 2021, 53 (02)
  • [3] Deep Visio-PhotoPlethysmoGraphy Reconstruction Pipeline for Non-invasive Cuff-less Blood Pressure Estimation
    Rundo, Francesco
    Trenta, Francesca
    Leotta, Roberto
    Battiato, Sebastiano
    PROCEEDINGS OF THE INTERNATIONAL CONFERENCE ON IMAGE PROCESSING AND VISION ENGINEERING (IMPROVE), 2021, : 75 - 80
  • [4] Cuff-less Blood Pressure Measurement Based on Deep Convolutional Neural Network
    Liu, ZengDing
    Miao, Fen
    Wang, Ruxin
    Liu, Jikui
    Wen, Bo
    Li, Ye
    2019 41ST ANNUAL INTERNATIONAL CONFERENCE OF THE IEEE ENGINEERING IN MEDICINE AND BIOLOGY SOCIETY (EMBC), 2019, : 3775 - 3778
  • [5] Photoplethysmography Signal Wavelet Enhancement and Novel Features Selection for Non-Invasive Cuff-Less Blood Pressure Monitoring
    Attivissimo, Filippo
    De Palma, Luisa
    Di Nisio, Attilio
    Scarpetta, Marco
    Lanzolla, Anna Maria Lucia
    SENSORS, 2023, 23 (04)
  • [6] Cuff-Less Blood Pressure Estimation From Photoplethysmography via Visibility Graph and Transfer Learning
    Wang, Weinan
    Mohseni, Pedram
    Kilgore, Kevin L.
    Najafizadeh, Laleh
    IEEE JOURNAL OF BIOMEDICAL AND HEALTH INFORMATICS, 2022, 26 (05) : 2075 - 2085
  • [7] Continuous Cuff-Less Blood Pressure Estimation Based on Combined Information Using Deep Learning Approach
    Wu, Dan
    Xu, Lin
    Zhang, Ruiqin
    Zhang, Heye
    Ren, Lijie
    Zhang, Yuan-Ting
    JOURNAL OF MEDICAL IMAGING AND HEALTH INFORMATICS, 2018, 8 (06) : 1290 - 1299
  • [8] Cuff-less Blood Pressure Estimation Using Kalman Filter on Android Platform
    He, Zhengling
    Chen, Xianxiang
    Fang, Zhen
    Tang, Minfang
    Li, Junxia
    Xia, Shanhong
    2017 IEEE 19TH INTERNATIONAL CONFERENCE ON E-HEALTH NETWORKING, APPLICATIONS AND SERVICES (HEALTHCOM), 2017,
  • [9] Symmetrical Photoplethysmogram Signal-Based Cuff-Less Blood Pressure Estimation
    Liu, Zehua
    Xiao, Linxia
    Liu, Yang
    Gao, Liyu
    Zhang, Jinlong
    Si, Weixin
    IEEE SENSORS JOURNAL, 2024, 24 (06) : 8902 - 8911
  • [10] BrainZ-BP: A Noninvasive Cuff-Less Blood Pressure Estimation Approach Leveraging Brain Bio-Impedance and Electrocardiogram
    Yang, Bufang
    Liu, Le
    Wu, Wenxuan
    Zhou, Mengliang
    Liu, Hongxing
    Ning, Xinbao
    IEEE TRANSACTIONS ON INSTRUMENTATION AND MEASUREMENT, 2024, 73 : 1 - 13