Comparison between new-generation SiPM-based and conventional PMT-based TOF-PET/CT

被引:83
作者
Wagatsuma, Kei [1 ]
Miwa, Kenta [2 ]
Sakata, Muneyuki [1 ]
Oda, Keiichi [1 ,3 ]
Ono, Haruka [2 ]
Kameyama, Masashi [4 ]
Toyohara, Jun [1 ]
Ishii, Kenji [1 ]
机构
[1] Tokyo Metropolitan Inst Gerontol, Res Team Neuroimaging, Tokyo, Japan
[2] Int Univ Hlth & Welf, Sch Hlth Sci, Ohtawara, Japan
[3] Hokkaido Univ Sci, Fac Hlth Sci, Sapporo, Hokkaido, Japan
[4] Tokyo Metropolitan Geriatr Hosp, Dept Diagnost Radiol, Tokyo, Japan
来源
PHYSICA MEDICA-EUROPEAN JOURNAL OF MEDICAL PHYSICS | 2017年 / 42卷
关键词
Silicon-photomultiplier; National Electrical Manufactured Association; Instrumentation; Physical performance; Image quality; TIME-OF-FLIGHT; WHOLE-BODY PET; POINT-SPREAD FUNCTION; IMAGE-RECONSTRUCTION; AMYLOID PET; PERFORMANCE-MEASUREMENTS; CLINICAL-EVALUATION; COUNT RATES; BRAIN FDG; SCANNER;
D O I
10.1016/j.ejmp.2017.09.124
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Purpose: This study aimed to determine whether the SiPM-PET/CT, Discovery MI (DMI) performs better than the PMT-PET/CT system, Discovery 710 (D710). Methods: The physical performance of both systems was evaluated using NEMA NU 2 standards. Contrast (%), uniformity and image noise (%) are criteria proposed by the Japanese Society of Nuclear Medicine (JSNM) for phantom tests and were determined in images acquired from Hoffman and uniform phantoms using the DMI and D710. Brain and whole-body [F-18] FDG images were also acquired from a healthy male using the DMI and D710. Results: The spatial resolution at 1.0 cm off-center in the DMI and D710 was 3.91 and 4.52 mm, respectively. The sensitivity of the DMI and D710 was 12.62 and 7.50 cps/kBq, respectively. The observed peak noise-equivalent count rates were 185.6 kcps at 22.5 kBq/mL and 137.0 kcps at 29.0 kBq/mL, and the scatter fractions were 42.1% and 37.9% in the DMI and D710, respectively. The D710 had better contrast recovery and lower background variability. Contrast, uniformity and image noise in the DMI were 61.0%, 0.0225, and 7.85%, respectively. These outcomes were better than those derived from the D710 and satisfied the JSNM criteria. Brain images acquired by the DMI had better grey-to-white matter contrast and lower image noise at the edge of axial field of view. Conclusions: The DMI offers better sensitivity, performance under conditions of high count rates and image quality than the conventional PMT-PET/CT system, D710.
引用
收藏
页码:203 / 210
页数:8
相关论文
共 49 条
  • [1] Quantitative comparison of OSEM and penalized likelihood image reconstruction using relative difference penalties for clinical PET
    Ahn, Sangtae
    Ross, Steven G.
    Asma, Evren
    Miao, Jun
    Jin, Xiao
    Cheng, Lishui
    Wollenweber, Scott D.
    Manjeshwar, Ravindra M.
    [J]. PHYSICS IN MEDICINE AND BIOLOGY, 2015, 60 (15) : 5733 - 5751
  • [2] Optimization of image reconstruction conditions with phantoms for brain FDG and amyloid PET imaging
    Akamatsu, Go
    Ikari, Yasuhiko
    Nishio, Tomoyuki
    Nishida, Hiroyuki
    Ohnishi, Akihito
    Aita, Kazuki
    Sasaki, Masahiro
    Sasaki, Masayuki
    Senda, Michio
    [J]. ANNALS OF NUCLEAR MEDICINE, 2016, 30 (01) : 18 - 28
  • [3] Impact of Time-of-Flight PET/CT with a Large Axial Field of View for Reducing Whole-Body Acquisition Time
    Akamatsu, Go
    Uba, Koji
    Taniguchi, Takafumi
    Mitsumoto, Katsuhiko
    Narisue, Akihiro
    Tsutsui, Yuji
    Sasaki, Masayuki
    [J]. JOURNAL OF NUCLEAR MEDICINE TECHNOLOGY, 2014, 42 (02) : 101 - 104
  • [4] Improvement in PET/CT Image Quality with a Combination of Point-Spread Function and Time-of-Flight in Relation to Reconstruction Parameters
    Akamatsu, Go
    Ishikawa, Kaori
    Mitsumoto, Katsuhiko
    Taniguchi, Takafumi
    Ohya, Nobuyoshi
    Baba, Shingo
    Abe, Koichiro
    Sasaki, Masayuki
    [J]. JOURNAL OF NUCLEAR MEDICINE, 2012, 53 (11) : 1716 - 1722
  • [5] [Anonymous], 2012, 22012 NEMA NU
  • [6] 18F-FDG silicon photomultiplier PET/CT: A pilot study comparing semi-quantitative measurements with standard PET/CT
    Baratto, Lucia
    Park, Sonya Young
    Hatami, Negin
    Davidzon, Guido
    Srinivas, Shyam
    Gambhir, Sanjiv Sam
    Iagaru, Andrei
    [J]. PLOS ONE, 2017, 12 (06):
  • [7] Staging the axilla in breast cancer patients with 18F-FDG PET: how small are the metastases that we can detect with new generation clinical PET systems?
    Bellevre, Dimitri
    Fournier, Cecile Blanc
    Switsers, Odile
    Dugue, Audrey Emmanuelle
    Levy, Christelle
    Allouache, Djelila
    Desmonts, C dric
    Crouet, Hubert
    Guilloit, Jean-Marc
    Grellard, Jean-Michel
    Aide, Nicolas
    [J]. EUROPEAN JOURNAL OF NUCLEAR MEDICINE AND MOLECULAR IMAGING, 2014, 41 (06) : 1103 - 1112
  • [8] Physical Performance of the new hybrid PET/CT Discovery-690
    Bettinardi, V.
    Presotto, L.
    Rapisarda, E.
    Picchio, M.
    Gianolli, L.
    Gilardi, M. C.
    [J]. MEDICAL PHYSICS, 2011, 38 (10) : 5394 - 5411
  • [9] Evaluation of a SiPM array coupled to a Gd3Al2Ga3O12:Ce (GAGG:Ce) discrete scintillator
    David, S.
    Georgiou, M.
    Fysikopoulos, E.
    Loudos, G.
    [J]. PHYSICA MEDICA-EUROPEAN JOURNAL OF MEDICAL PHYSICS, 2015, 31 (07): : 763 - 766
  • [10] Performance measurements for the PET/CT Discovery-600 using NEMA NU 2-2007 standards
    De Ponti, E.
    Morzenti, S.
    Guerra, L.
    Pasquali, C.
    Arosio, M.
    Bettinardi, V.
    Crespi, A.
    Gilardi, M. C.
    Messa, C.
    [J]. MEDICAL PHYSICS, 2011, 38 (02) : 968 - 974