Study of adhesive bondlines in modified wood with fluorescence microscopy and X-ray micro-computed tomography

被引:38
|
作者
Bastani, Alireza [1 ]
Adamopoulos, Stergios [2 ]
Koddenberg, Tim [1 ]
Militz, Holger [1 ]
机构
[1] Univ Gottingen, Burckhardt Inst, Wood Biol & Wood Prod, Busgenweg 4, D-370377 Gottingen, Germany
[2] Linnaeus Univ, Dept Forestry & Wood Technol, Luckligs Plats 1, S-35195 Vaxjo, Sweden
关键词
Modified wood; Adhesive penetration; Bondline; Fluorescence microscopy; X-ray tomography; UREA-FORMALDEHYDE RESIN; CELL-WALLS; PENETRATION; PERFORMANCE; BONDS;
D O I
10.1016/j.ijadhadh.2016.04.006
中图分类号
TQ [化学工业];
学科分类号
0817 ;
摘要
The quantitative penetration of three coldset wood adhesives [one-component polyurethane (PU), emulsion polymer isocyanate (EPI), poly (vinyl acetate) (PVAc)] under hydraulic pressure into different types of modified wood was studied using fluorescence microscopy and the results were compared to these of a previous study without pressure on adjacent wood samples. The effective penetration (EP) of PU was negatively affected by furfurlylation and NMM modification when pressure was applied. For PVAc, 30% NMM treatment and heat treatment of Scots pine and beech at 210 degrees C had a negative effect on its EP, but against this the EP of this adhesive increased after heat treatment of beech at 195 degrees C. In the case of furfurylation, the depth of penetration of all adhesives was less into wood treated with higher concentration of furfuryl alcohol. PU showed a much deeper penetration into NMM-modified and heat treated wood than the other adhesives with the exception of heat-treated beech at 195 degrees C. Application of pressure led to rather different results as compared to the EP data when no pressure was applied. The three-dimensional (3D) visualisation of the penetration of PU adhesive into heat-treated Scots pine was also examined by X-ray micro-computed tomography (X mu CT). The 3D flow pattern of PU adhesive into heat-treated Scots pine was clearly depicted by X mu CT. (C) 2016 Elsevier Ltd. All rights reserved.
引用
收藏
页码:351 / 358
页数:8
相关论文
共 50 条
  • [21] 3D-Reconstruction and characterization of the pore microstructure within the asphalt FAM using the X-ray micro-computed tomography
    Zhao, Zili
    Jiang, Jiwang
    Ni, Fujian
    Ma, Xiang
    CONSTRUCTION AND BUILDING MATERIALS, 2021, 272
  • [22] X-ray micro-computed tomography investigation of fibre length degradation during the processing steps of short-fibre composites
    Joffre, Thomas
    Miettinen, Arttu
    Berthold, Fredrik
    Gamstedt, E. Kristofer
    COMPOSITES SCIENCE AND TECHNOLOGY, 2014, 105 : 127 - 133
  • [23] X-ray methods to observe and quantify adhesive penetration into wood
    Jakes, Joseph E.
    Frihart, Charles R.
    Hunt, Christopher G.
    Yelle, Daniel J.
    Plaza, Nayomi Z.
    Lorenz, Linda
    Grigsby, Warren
    Ching, Daniel J.
    Kamke, Fred
    Gleber, Sophie-Charlotte
    Vogt, Stefan
    Xiao, Xianghui
    JOURNAL OF MATERIALS SCIENCE, 2019, 54 (01) : 705 - 718
  • [24] X-ray computed tomography of the heart
    Wijesekera, Nevin T.
    Duncan, Mark K.
    Padley, Simon P. G.
    BRITISH MEDICAL BULLETIN, 2010, 93 (01) : 49 - 67
  • [25] Structure characterization of the clogging process of coarse fibrous filter media during solid particle loading with X-ray micro-computed tomography
    Song, Yu
    Shim, Eunkyoung
    SEPARATION AND PURIFICATION TECHNOLOGY, 2021, 273
  • [26] Spectral X-ray computed micro tomography: 3-dimensional chemical imaging
    Sittner, Jonathan
    Godinho, Jose R. A.
    Renno, Axel D.
    Cnudde, Veerle
    Boone, Marijn
    De Schryver, Thomas
    Van Loo, Denis
    Merkulova, Margarita
    Roine, Antti
    Liipo, Jussi
    X-RAY SPECTROMETRY, 2021, 50 (02) : 92 - 105
  • [27] Phenol formaldehyde adhesives formulated for advanced X-ray imaging in wood-composite bondlines
    Paris, Jesse L.
    Kamke, Frederick A.
    Mbachu, Reginald
    Gibson, Sara Kraushaar
    JOURNAL OF MATERIALS SCIENCE, 2014, 49 (02) : 580 - 591
  • [28] Porosity estimation method by X-ray computed tomography
    Taud, H
    Martinez-Angeles, R
    Parrot, JF
    Hernandez-Escobedo, L
    JOURNAL OF PETROLEUM SCIENCE AND ENGINEERING, 2005, 47 (3-4) : 209 - 217
  • [29] Non-destructive PCB Reverse Engineering Using X-ray Micro Computed Tomography
    Asadizanjani, Navid
    Shahbazmohamadi, Sina
    Tehranipoor, Mark
    Forte, Domenic
    ISTFA 2015: CONFERENCE PROCEEDINGS FROM THE 41ST INTERNATIONAL SYMPOSIUM FOR TESTING AND FAILURE ANALYSIS, 2015, : 164 - 172
  • [30] Mechanical and radiation shielding properties of concrete reinforced with boron-basalt fibers using Digital Image Correlation and X-ray micro-computed tomography
    Skarzynski, Lukasz
    CONSTRUCTION AND BUILDING MATERIALS, 2020, 255