ICP-AES detection of ultratrace aluminum(III) and chromium(III) ions with a microcolumn preconcentration system using dynamically immobilized 8-hydroxyquinoline on TiO2 nanoparticles

被引:43
作者
Liang, P [1 ]
Yang, LH [1 ]
Hu, B [1 ]
Jiang, ZC [1 ]
机构
[1] Wuhan Univ, Dept Chem, Wuhan 430072, Peoples R China
关键词
D O I
10.2116/analsci.19.1167
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
Titanium dioxide nanoparticle dynamically loaded with 8-hydroxyquinoline (nanometer TiO2-Oxine) was used as a solid-phase extractant for the preconcentration of trace amounts of aluminum(III) and chromium(III) prior to their determination by inductively coupled plasma atomic emission spectrometry (ICP-AES). The optimal conditions for preparing nanometer TiO2-Oxine were obtained. Also, the separation/preconcentration conditions of analytes, including the effects of the pH, the sample flow rate and the volume, the elution solution and the interfering ions on the recovery,of the analytes were investigated. At pH 6.0, the adsorption capacity of nanometer TiO2-Oxine was found to be 5.23 mg g(-1) and 9.58 mg g(-1) for Al(III) and Cr(III), respectively. An enrichment factor of 50 was achieved by this method, and the detection limits (3sigma) for Al(III) and Cr(III) were 1.96 and 0.32 mug L-1 respectively. The proposed method was applied for the determination of trace AI(III) and Cr(III) in biological samples and lake water with satisfactory results.
引用
收藏
页码:1167 / 1171
页数:5
相关论文
共 34 条
[1]   SIMULTANEOUS MULTIELEMENT DETERMINATION OF TRACE-METALS USING 10 ML OF SEAWATER BY INDUCTIVELY COUPLED PLASMA ATOMIC EMISSION-SPECTROMETRY WITH GALLIUM COPRECIPITATION AND MICROSAMPLING TECHNIQUE [J].
AKAGI, T ;
HARAGUCHI, H .
ANALYTICAL CHEMISTRY, 1990, 62 (01) :81-85
[2]   Flow injection on-line electrothermal atomic absorption spectrometry [J].
Alonso, EV ;
de Torres, AG ;
Pavón, JMC .
TALANTA, 2001, 55 (02) :219-232
[3]   Sorption of arsenic, bismuth, mercury, antimony, selenium and tin on dithiocarbamate loaded polyurethane foam as a preconcentration method for their determination in water samples by simultaneous inductively coupled plasma atomic emission spectrometry and electrothermal atomic absorption spectrometry [J].
Arpadjan, S ;
Vuchkova, L ;
Kostadinova, E .
ANALYST, 1997, 122 (03) :243-246
[4]   DETERMINATION OF CHROMIUM SPECIATION IN NATURAL-WATERS BY ELECTRODEPOSITION ON GRAPHITE TUBES FOR ELECTROTHERMAL ATOMIZATION [J].
BATLEY, GE ;
MATOUSEK, JP .
ANALYTICAL CHEMISTRY, 1980, 52 (11) :1570-1574
[5]  
BERHTON G, 1996, COORDIN CHEM REV, V149, P241
[6]   APPLICATION OF THE LIGAND VAPOR TECHNIQUE TO THE VOLATILIZATION OF UNSTABLE CHELATE COMPOUNDS (PARTICULARLY IRON(III) TRIFLUOROACETYLACETONATE) IN AAS [J].
CASTILLO, JR ;
MIR, JM ;
GARCIARUIZ, ME ;
BENDICHO, C .
FRESENIUS JOURNAL OF ANALYTICAL CHEMISTRY, 1990, 338 (06) :721-725
[7]   PRECONCENTRATION OF TRACE-ELEMENTS IN ALUMINUM-ALLOYS USING A CHELATING ION-EXCHANGER AND DETERMINATION BY ICP-AES [J].
DUMONT, J ;
COTE, M ;
HUBERT, J .
APPLIED SPECTROSCOPY, 1989, 43 (07) :1132-1135
[8]  
EDWARDSON JA, 1991, J INORG BIOCHEM, V43, P485
[9]  
Fang Z., 1993, FLOW INJECTION SEPAR
[10]   Trends and potentials in flow injection on-line separation and preconcentration techniques for electrothermal atomic absorption spectrometry [J].
Fang, ZL .
SPECTROCHIMICA ACTA PART B-ATOMIC SPECTROSCOPY, 1998, 53 (10) :1371-1379