Influence of cutting force on temperature, microcracks and chip morphology during rotary ultrasonic bone drilling: An in-vitro study

被引:19
作者
Agarwal, Raj [1 ]
Singh, Ravinder Pal [2 ]
Gupta, Vishal [1 ]
Singh, Jaskaran [1 ]
机构
[1] Thapar Inst Engn & Technol Patiala, Mech Engn Dept, Patiala 147004, Punjab, India
[2] Maharishi Markandeshwar Deemed Be Univ, Dept Mech Engn, Mullana, India
关键词
Bone drilling; Bone chips; Cutting force; Microcracks; Temperature; RISE; SITE; TOOL;
D O I
10.1007/s40430-022-03608-6
中图分类号
TH [机械、仪表工业];
学科分类号
0802 ;
摘要
Mechanical and thermal damage due to cutting force and temperature rise during bone drilling plays a significant role in implant failure during osteosynthesis. High cutting force results in hole inaccuracy and weakens the stability between bone and implant. In comparison, temperature above 47 degrees C during drilling of bone results in the permanent death of regenerative bony cells consequences of thermal osteonecrosis. Microcracks at the drill site result in bone delamination and affect the holding strength at the bone-screw interface, resulting in implant failure. Accumulation of bone chips produced during drilling may cause chip clogging. The cutting force, microcracks, bone chip accumulation, and temperature rise are significant reasons for implant instability and revision surgery. Therefore, the present work uses the rotary ultrasonic bone drilling (RUBD) technique of the pig femur bone to monitor cutting force, temperature, microcracks and bone debris generated during the drilling. The results were also compared with conventional bone drilling (CBD). The twisted surgical drill bit was used during CBD and the diamond-impregnated tool was used during RUBD with the same diameters of 3.5 mm. The histopathological analysis was conducted at the drilled site to observe the tissue damage and the effect of heat generation on bone morphology. The output parameters were correlated, and the influence of cutting force on temperature rise, microcracks, and chip morphology was observed. This study showed that the increase in cutting force from 35.63 to 57.66 N in RUBD, and 54.83 to 78.7 N in CBD, resulted in a decrease in temperature rise by 51.5 and 32.7%, respectively. In contrast, the intensity of microcracks and chips size increased with the increase in cutting force for both RUBD and CBD techniques. Moreover, the RUBD technique reduces cutting force, temperature rise, microcracks and bone chip morphology as compared to CBD.
引用
收藏
页数:10
相关论文
共 42 条
  • [11] Thermal analysis during bone drilling using rigid polyurethane foams: numerical and experimental methodologies
    Fernandes, M. G. A.
    Fonseca, E. M. M.
    Natal, R. J.
    [J]. JOURNAL OF THE BRAZILIAN SOCIETY OF MECHANICAL SCIENCES AND ENGINEERING, 2016, 38 (07) : 1855 - 1863
  • [12] Development of bone chip-vacuum system in orthopedic drilling process
    Gok, Kadir
    Erdem, Mehmet
    Kisioglu, Yasin
    Gok, Arif
    Tumsek, Mert
    [J]. JOURNAL OF THE BRAZILIAN SOCIETY OF MECHANICAL SCIENCES AND ENGINEERING, 2021, 43 (04)
  • [13] Development of a new driller system to prevent the osteonecrosis in orthopedic surgery applications
    Gok, Kadir
    Buluc, Levent
    Muezzinoglu, Umit Sefa
    Kisioglu, Yasin
    [J]. JOURNAL OF THE BRAZILIAN SOCIETY OF MECHANICAL SCIENCES AND ENGINEERING, 2015, 37 (02) : 549 - 558
  • [14] In vitro comparison of conventional surgical and rotary ultrasonic bone drilling techniques
    Gupta, Vishal
    Singh, Ravinder Pal
    Pandey, Pulak M.
    Gupta, Ravi
    [J]. PROCEEDINGS OF THE INSTITUTION OF MECHANICAL ENGINEERS PART H-JOURNAL OF ENGINEERING IN MEDICINE, 2020, 234 (04) : 398 - 411
  • [15] An in-vitro study of cutting force and torque during rotary ultrasonic bone drilling
    Gupta, Vishal
    Pandey, Pulak Mohan
    [J]. PROCEEDINGS OF THE INSTITUTION OF MECHANICAL ENGINEERS PART B-JOURNAL OF ENGINEERING MANUFACTURE, 2018, 232 (09) : 1549 - 1560
  • [16] Rotary ultrasonic drilling on bone: A novel technique to put an end to thermal injury to bone
    Gupta, Vishal
    Pandey, Pulak M.
    Gupta, Ravi K.
    Mridha, Asit R.
    [J]. PROCEEDINGS OF THE INSTITUTION OF MECHANICAL ENGINEERS PART H-JOURNAL OF ENGINEERING IN MEDICINE, 2017, 231 (03) : 189 - 196
  • [17] Rotary ultrasonic bone drilling: Improved pullout strength and reduced damage
    Gupta, Vishal
    Pandey, Pulak M.
    Silberschmidt, Vadim V.
    [J]. MEDICAL ENGINEERING & PHYSICS, 2017, 41 : 1 - 8
  • [18] Experimental investigation and statistical modeling of temperature rise in rotary ultrasonic bone drilling
    Gupta, Vishal
    Pandey, Pulak M.
    [J]. MEDICAL ENGINEERING & PHYSICS, 2016, 38 (11) : 1330 - 1338
  • [19] Influence of the drill material and method of cooling on the development of intrabony temperature during preparation of the site of an implant
    Harder, Soenke
    Egert, Christopher
    Wenz, Hans J.
    Jochens, Arne
    Kern, Matthias
    [J]. BRITISH JOURNAL OF ORAL & MAXILLOFACIAL SURGERY, 2013, 51 (01) : 74 - 78
  • [20] Comprehensive analysis on orthopedic drilling: A state-of-the-art review
    Jamil, Muhammad
    Rafique, Saima
    Khan, Aqib Mashood
    Hegab, Hussien
    Mia, Mozammel
    Gupta, Munish Kumar
    Song, Qinghua
    [J]. PROCEEDINGS OF THE INSTITUTION OF MECHANICAL ENGINEERS PART H-JOURNAL OF ENGINEERING IN MEDICINE, 2020, 234 (06) : 537 - 561