Calculation of the effective dose and its variation from environmental gamma ray sources

被引:48
作者
Saito, K
Petoussi-Henss, N
Zankl, M
机构
[1] Japan Atom Energy Res Inst, Tokai, Ibaraki 31911, Japan
[2] GSF, Natl Res Ctr Environm & Hlth, Inst Radiat Protect, D-85764 Neuherberg, Germany
来源
HEALTH PHYSICS | 1998年 / 74卷 / 06期
关键词
effective dose; dose equivalent; effective; gamma radiation; Monte Carlo;
D O I
10.1097/00004032-199806000-00007
中图分类号
X [环境科学、安全科学];
学科分类号
08 ; 0830 ;
摘要
Effective dose, an indicator of the stochastic effect of radiation, has been widely used in dose evaluation in the environment. Though conversion factors have been used to obtain E from the air kerma or air absorbed dose, the variation of the conversion factors due to the change of exposure conditions has not been sufficiently investigated. This report documents an investigation of the variation of the effective dose per air kerma for environmental gamma rays depending on the exposure conditions using anthropomorphic phantoms and Monte Carlo calculations, taking into account the precise angular and energy distributions of the environmental gamma rays incident on the human body. As causes of the variation, posture of human bodies, biases of environmental source distributions, and body size were considered. The variation of effective dose in a prone position compared with that in a standing position was found to be within 30%, The bias of environmental sources causes the effective dose per air kerma to vary by 20% at maximum, but in some cases for low-energy gamma rays the variation was found to be up to 40% due to the change in the energy spectrum, The effective dose for a new born infant was estimated to be higher than that for an adult by a maximum of 80-90% for low-energy gamma rays from anthropogenic sources because of a lower shielding effect of the smaller body. The variation of the effective dose equivalent shows a similar tendency to the effective dose. Consequently, this study made it possible to estimate the uncertainties of effective dose and effective dose equivalent evaluated from air kerma or absorbed dose in air using the standard available conversion factors.
引用
收藏
页码:698 / 706
页数:9
相关论文
共 40 条
[31]   Monte Carlo calculation of organ and effective doses due to photon and neutron point sources and typical X-ray examinations: Results of an international intercomparison exercise [J].
Huet, Christelle ;
Eakins, Jonathan ;
Zankl, Maria ;
Maria Gomez-Ros, Jose ;
Jansen, Jan ;
Moraleda, Montserrat ;
Struelens, Lara ;
Akar, Deepak K. ;
Borbinha, Jorge ;
Brkic, Hrvoje ;
Duc Ky Bui ;
Capello, Kevin ;
Thi My Linh Dang ;
Desorgher, Laurent ;
Di Maria, Salvatore ;
Epstein, Lior ;
Faj, Dario ;
Fantinova, Karin ;
Ferrari, Paolo ;
Gossio, Sebastian ;
Hunt, John ;
Jovanovic, Zoran ;
Kim, Han Sung ;
Krstic, Dragana ;
Ngoc Thiem Le ;
Lee, Yi-Kang ;
Murugan, Manohari ;
Nadar, Minal Y. ;
Ngoc-Quynh Nguyen ;
Nikezic, Dragoslav ;
Patni, Hemant K. ;
Santos, Denison Souza ;
Tremblay, Marilyn ;
Trivino, Sebastian ;
Tyminska, Katarzyna .
RADIATION MEASUREMENTS, 2022, 150
[32]   Radial dose distribution, dose to water and dose rate constant for monoenergetic photon point sources from 10 keV to 2 MeV: EGS4 Monte Carlo model calculation [J].
Luxton, G ;
Jozsef, G .
MEDICAL PHYSICS, 1999, 26 (12) :2531-2538
[33]   Calculation of effective dose from measurements of secondary neutron spectra and scattered photon dose from dynamic MLC IMRT for 6 MV, 15 MV, and 18 MV beam energies [J].
Howell, RM ;
Hertel, NE ;
Wang, ZL ;
Hutchinson, J ;
Fullerton, GD .
MEDICAL PHYSICS, 2006, 33 (02) :360-368
[34]   Monte Carlo calculation of organ and effective dose rates from ground contaminated by Am-241: Results of an international intercomparison exercise [J].
Eakins, J. ;
Huet, C. ;
Brkic, H. ;
Capello, K. ;
Desorgher, L. ;
Epstein, L. ;
Hunt, J. G. ;
Kim, H. S. ;
Krstic, D. ;
Lee, Y-K ;
Manohari, M. ;
Nikezic, D. ;
Shukrun, R. H. ;
Souza-Santos, D. ;
Tyminska, K. .
RADIATION MEASUREMENTS, 2021, 148
[35]   CHARACTERISTICS OF RADIATION-FIELD IN LIVING ENVIRONMENT .1. DISTRIBUTION OF GAMMA AND COSMIC-RAY DOSE-RATE IN TOKYO AND ITS CHARACTERISTICS [J].
NAGAOKA, T ;
SAKAMOTO, R ;
TSUTSUMI, M ;
SAITO, K ;
MORIUCHI, S .
JOURNAL OF THE ATOMIC ENERGY SOCIETY OF JAPAN, 1990, 32 (04) :403-413
[36]   Patient effective radiation dose and associated risk from transmission scans using 153Gd line sources in cardiac spect studies [J].
Perisinakis, K ;
Theocharopoulos, N ;
Karkavitsas, N ;
Damilakis, J .
HEALTH PHYSICS, 2002, 83 (01) :66-74
[37]   Variation of annual effective dose from external ionizing radiation among radiation workers of Bahawalour Institute of Nuclear Medicine and Oncology (BINO), Pakistan [J].
Gadhi, M. A. ;
Fatmi, Sh. ;
Gadhi, M. Sh. ;
Mahmood, U. ;
Shakil, M. ;
Buzdar, S. A. .
INTERNATIONAL JOURNAL OF RADIATION RESEARCH, 2016, 14 (03) :229-235
[38]   Technique and Gender Specific Conversion Coefficients for Estimation of Effective Dose from Kerma Area Product During X-Ray Radiography of Chest [J].
Dimov, Asen ;
Tsanev, Ivan ;
Penev, Dimitar .
WORLD CONGRESS ON MEDICAL PHYSICS AND BIOMEDICAL ENGINEERING 2018, VOL 1, 2019, 68 (01) :719-723
[39]   A conversion method of air kerma from the primary, scatter, and leakage radiations to effective dose for calculating x-ray shielding barriers in mammography [J].
Kharrati, H .
MEDICAL PHYSICS, 2005, 32 (05) :1367-1374
[40]   Study on trace elements (using energy dispersive X-ray fluorescence technique) of edible seeds from Cicer arietinum L. plants developed from gamma irradiated seeds and variation of yielding capacity [J].
Maity, Jyoti Prakash ;
Kar, Sandeep ;
Chakraborty, Anindita ;
Sudershan, M. ;
Santra, Subhas Chandra .
JOURNAL OF RADIOANALYTICAL AND NUCLEAR CHEMISTRY, 2010, 283 (01) :225-230