Calculation of the effective dose and its variation from environmental gamma ray sources

被引:47
作者
Saito, K
Petoussi-Henss, N
Zankl, M
机构
[1] Japan Atom Energy Res Inst, Tokai, Ibaraki 31911, Japan
[2] GSF, Natl Res Ctr Environm & Hlth, Inst Radiat Protect, D-85764 Neuherberg, Germany
来源
HEALTH PHYSICS | 1998年 / 74卷 / 06期
关键词
effective dose; dose equivalent; effective; gamma radiation; Monte Carlo;
D O I
10.1097/00004032-199806000-00007
中图分类号
X [环境科学、安全科学];
学科分类号
08 ; 0830 ;
摘要
Effective dose, an indicator of the stochastic effect of radiation, has been widely used in dose evaluation in the environment. Though conversion factors have been used to obtain E from the air kerma or air absorbed dose, the variation of the conversion factors due to the change of exposure conditions has not been sufficiently investigated. This report documents an investigation of the variation of the effective dose per air kerma for environmental gamma rays depending on the exposure conditions using anthropomorphic phantoms and Monte Carlo calculations, taking into account the precise angular and energy distributions of the environmental gamma rays incident on the human body. As causes of the variation, posture of human bodies, biases of environmental source distributions, and body size were considered. The variation of effective dose in a prone position compared with that in a standing position was found to be within 30%, The bias of environmental sources causes the effective dose per air kerma to vary by 20% at maximum, but in some cases for low-energy gamma rays the variation was found to be up to 40% due to the change in the energy spectrum, The effective dose for a new born infant was estimated to be higher than that for an adult by a maximum of 80-90% for low-energy gamma rays from anthropogenic sources because of a lower shielding effect of the smaller body. The variation of the effective dose equivalent shows a similar tendency to the effective dose. Consequently, this study made it possible to estimate the uncertainties of effective dose and effective dose equivalent evaluated from air kerma or absorbed dose in air using the standard available conversion factors.
引用
收藏
页码:698 / 706
页数:9
相关论文
共 40 条
  • [21] The effect of density variation on photon dose calculation and its impact on intensity modulated radiotherapy and stereotactic body radiotherapy
    Liu, Qiang
    Liang, Jian
    Stanhope, Carl W.
    Yan, Di
    MEDICAL PHYSICS, 2016, 43 (10) : 5717 - 5729
  • [22] Estimation of the effective dose from radon ingestion and inhalation in drinking water sources of Mashhad, Iran
    Binesh, A.
    Mowlavi, A. A.
    Mohammadi, S.
    IRANIAN JOURNAL OF RADIATION RESEARCH, 2012, 10 (01): : 37 - 41
  • [23] Calculation of effective dose from external exposure to photons for the Male Adult voXel (MAX) phantom
    Vieira, JW
    Kramer, R
    Lima, FRA
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION B-BEAM INTERACTIONS WITH MATERIALS AND ATOMS, 2004, 213 : 654 - 657
  • [24] Radiation dose of 18F-FDG to lactating breasts, its effect on the effective dose and a more accurate effective dose from 18F-FDG
    Pencharz, Deborah
    McMeekin, Helena
    Wagner, Thomas
    Wickham, Fred
    NUCLEAR MEDICINE COMMUNICATIONS, 2016, 37 (08) : 860 - 864
  • [25] Comparison of effective dose to children and adults from dual X-ray absorptiometry examinations
    Blake, GM
    Naeem, M
    Boutros, M
    BONE, 2006, 38 (06) : 935 - 942
  • [26] Conversion coefficients for estimation of effective dose to patients from dose area product during fluoroscopy X-ray examinations
    Gosch, D.
    Gosch, K.
    Kahn, T.
    ROFO-FORTSCHRITTE AUF DEM GEBIET DER RONTGENSTRAHLEN UND DER BILDGEBENDEN VERFAHREN, 2007, 179 (10): : 1035 - 1042
  • [27] ROLE OF GAMMA-RAY DOSE-RATE AT THE SURFACE OF SPENT FUEL SHIPPING CASK IN CALCULATION OF DOSE-RATE DISTRIBUTION THROUGHOUT SHIP BY USING MANYCASK CODE
    YAMAKOSHI, H
    JOURNAL OF THE ATOMIC ENERGY SOCIETY OF JAPAN, 1990, 32 (01): : 92 - 100
  • [28] MEASUREMENT OF 222Rn IN BOTTLED WATERS FROM VARIOUS SOURCES AND ESTIMATION OF EFFECTIVE DOSE, SAUDI ARABIA
    Alshahri, F.
    ROMANIAN JOURNAL OF PHYSICS, 2017, 62 (7-8):
  • [29] Ambient Dose Equivalent, Effective Dose and Mean Sv/Gy Conversion Coefficients from Scattered X-Ray Spectra in Mammography
    Kunzel, R.
    Herdade, S. B.
    Costa, P. R.
    Terini, R. A.
    Levenhagen, R. S.
    WORLD CONGRESS ON MEDICAL PHYSICS AND BIOMEDICAL ENGINEERING 2006, VOL 14, PTS 1-6, 2007, 14 : 2092 - +
  • [30] Study of a method for theoretical calculation of the efficiency of a LaBr3(Ce) for detecting gamma-rays from point sources
    Ye, Erlei
    Shen, Chunxia
    Nan, Hongjie
    Lai, Yongfang
    APPLIED RADIATION AND ISOTOPES, 2024, 212