Calculation of the effective dose and its variation from environmental gamma ray sources

被引:47
|
作者
Saito, K
Petoussi-Henss, N
Zankl, M
机构
[1] Japan Atom Energy Res Inst, Tokai, Ibaraki 31911, Japan
[2] GSF, Natl Res Ctr Environm & Hlth, Inst Radiat Protect, D-85764 Neuherberg, Germany
来源
HEALTH PHYSICS | 1998年 / 74卷 / 06期
关键词
effective dose; dose equivalent; effective; gamma radiation; Monte Carlo;
D O I
10.1097/00004032-199806000-00007
中图分类号
X [环境科学、安全科学];
学科分类号
08 ; 0830 ;
摘要
Effective dose, an indicator of the stochastic effect of radiation, has been widely used in dose evaluation in the environment. Though conversion factors have been used to obtain E from the air kerma or air absorbed dose, the variation of the conversion factors due to the change of exposure conditions has not been sufficiently investigated. This report documents an investigation of the variation of the effective dose per air kerma for environmental gamma rays depending on the exposure conditions using anthropomorphic phantoms and Monte Carlo calculations, taking into account the precise angular and energy distributions of the environmental gamma rays incident on the human body. As causes of the variation, posture of human bodies, biases of environmental source distributions, and body size were considered. The variation of effective dose in a prone position compared with that in a standing position was found to be within 30%, The bias of environmental sources causes the effective dose per air kerma to vary by 20% at maximum, but in some cases for low-energy gamma rays the variation was found to be up to 40% due to the change in the energy spectrum, The effective dose for a new born infant was estimated to be higher than that for an adult by a maximum of 80-90% for low-energy gamma rays from anthropogenic sources because of a lower shielding effect of the smaller body. The variation of the effective dose equivalent shows a similar tendency to the effective dose. Consequently, this study made it possible to estimate the uncertainties of effective dose and effective dose equivalent evaluated from air kerma or absorbed dose in air using the standard available conversion factors.
引用
收藏
页码:698 / 706
页数:9
相关论文
共 40 条
  • [1] Effective dose equivalent due to gamma-ray emissions from hot particles
    Walters, MD
    Miller, WH
    Casey, SL
    Graham, C
    HEALTH PHYSICS, 1999, 76 (05): : 564 - 566
  • [2] Effective dose conversion coefficient for gamma ray exposure from an overhead plume
    Dey, Riya
    Patni, H. K.
    Singh, Kapil Deo
    Kulkarni, M. S.
    Anand, S.
    PHYSICS IN MEDICINE AND BIOLOGY, 2019, 64 (15)
  • [3] Effective dose equivalent and effective dose for photon exposures from point and disk sources on the floor
    Kim, CH
    Reece, WD
    Poston, JW
    HEALTH PHYSICS, 1998, 75 (02): : 170 - 178
  • [4] Annual effective dose from environmental gamma radiation in Bushehr city
    Ali Mahmoud Pashazadeh
    Mahdi Aghajani
    Iraj Nabipour
    Majid Assadi
    Journal of Environmental Health Science and Engineering, 12
  • [5] Annual effective dose from environmental gamma radiation in Bushehr city
    Pashazadeh, Ali Mahmoud
    Aghajani, Mahdi
    Nabipour, Iraj
    Assadi, Majid
    JOURNAL OF ENVIRONMENTAL HEALTH SCIENCE AND ENGINEERING, 2014, 12
  • [6] X-RAY DOSE ESTIMATION FROM CATHODE RAY TUBE MONITORS BY MONTE CARLO CALCULATION
    Khaledi, Navid
    Arbabi, Azim
    Dabaghi, Moloud
    HEALTH PHYSICS, 2015, 108 (04): : 401 - 406
  • [7] Effective dose equivalent for point gamma sources located 10 cm near the body
    Xu, X. George
    Bushart, Sean
    Anderson, Ralph
    HEALTH PHYSICS, 2006, 91 (02): : 108 - 118
  • [8] Environmental gamma-ray dose rate in Aomori Prefecture, Japan
    Iyogi, T
    Ueda, S
    Hisamatsu, S
    Kondo, K
    Haruta, H
    Katagiri, H
    Kurabayashi, M
    Nakamura, Y
    Tsuji, N
    HEALTH PHYSICS, 2002, 82 (04): : 521 - 526
  • [9] Gamma-Ray Dose From an Overhead Plume
    McNaughton, Michael W.
    Gillis, Jessica M.
    Ruedig, Elizabeth
    Whicker, Jeffrey J.
    Fuehne, David P.
    HEALTH PHYSICS, 2017, 112 (05): : 445 - 450
  • [10] Gonad, bone marrow and effective dose to the population of more than 90 towns and cities of Iran, arising from environmental gamma radiation
    Toossi, M. T. Bahreyni
    Bayani, Sh.
    Yarahmadi, M.
    Aghamir, A.
    Jomehzadeh, A.
    Parast, M. Hagh
    Tamjidi, A.
    IRANIAN JOURNAL OF RADIATION RESEARCH, 2009, 7 (01): : 41 - 47