Spatial organization of peptide nanotubes for electrochemical devices

被引:41
作者
Cipriano, T. C. [1 ,2 ]
Takahashi, P. M. [1 ,2 ]
de Lima, D. [1 ,2 ]
Oliveira, V. X., Jr. [1 ]
Souza, J. A. [1 ]
Martinho, H. [1 ]
Alves, W. A. [1 ,2 ]
机构
[1] Univ Fed ABC, Ctr Ciencias Nat & Humanas, Santo Andre, SP, Brazil
[2] Inst Nacl Ciencia & Tecnol Bioanalit, BR-13083970 Campinas, SP, Brazil
基金
巴西圣保罗研究基金会;
关键词
DIRECT ELECTRON-TRANSFER; SOLID-PHASE SYNTHESIS; HYDROGEN-PEROXIDE; NANOTECHNOLOGICAL APPLICATIONS; DIPHENYLALANINE PEPTIDE; INFRARED-SPECTROSCOPY; CARBON NANOTUBES; FABRICATION; MICROPEROXIDASE; NANOSTRUCTURES;
D O I
10.1007/s10853-010-4478-4
中图分类号
T [工业技术];
学科分类号
08 ;
摘要
A novel biosensor for hydrogen peroxide was developed by combining the known properties of microperoxidase-11 (MP11) as an oxidation catalyst, and the interesting properties of diphenylalanine peptide nanotubes (PNTs) as a supporting matrix to allow a good bioelectrochemical interface. In this case, the synthesized MP11/PNTs were immobilized onto the ITO electrode surface via layer-by-layer (LBL) deposition, using poly(allylamine hydrochloride) (PAH) as positively charged polyelectrolyte layers. The PNTs provide a favorable microenvironment for MP11 to perform direct electron transfer to the electrode surface. The resulting electrodes showed a pair of well-defined redox peaks with formal potential at about -343 mV (versus SCE) in phosphate buffer solution (pH 7). The experimental results also demonstrated that the resulting biosensor exhibited good electrocatalytic activity to the reduction of H2O2 with a sensitivity of 9.43 mu A cm(-2) mmol(-1) L, and a detection limit of 6 mu mol L-1 at the signal-to-noise ratio of 3. Moreover, we also observed that the peptides self-assembly can be influenced upon changing the pH of the solution. Alkaline solution appears to favor the packing of diphenylalanine nanotubes being closer than acidic or neutral conditions. The study proved that the combination of PNTs with MP11 is able to open new opportunities for the design of enzymatic biosensors with potential applications in practice.
引用
收藏
页码:5101 / 5108
页数:8
相关论文
共 45 条
[11]   The structure of nanotubes formed by diphenylalanine, the core recognition motif of Alzheimer's β-amyloid polypeptide [J].
Goerbitz, Carl Henrik .
CHEMICAL COMMUNICATIONS, 2006, (22) :2332-2334
[12]  
Görbitz CH, 2001, CHEM-EUR J, V7, P5153, DOI 10.1002/1521-3765(20011203)7:23<5153::AID-CHEM5153>3.0.CO
[13]  
2-N
[14]   Morphology Control of One-Dimensional Peptide Nanostructures [J].
Han, Tae Hee ;
Park, Ji Sun ;
Oh, Jun Kyun ;
Kim, Sang Ouk .
JOURNAL OF NANOSCIENCE AND NANOTECHNOLOGY, 2008, 8 (10) :5547-5550
[15]   Synthesis and electrochemical properties of single-walled carbon nanotube-gold nanoparticle composites [J].
Jiang, Hui-Jun ;
Zhao, Yu ;
Yang, Hui ;
Akins, D. L. .
MATERIALS CHEMISTRY AND PHYSICS, 2009, 114 (2-3) :879-883
[16]   COLOR TEST FOR TERMINAL PROLYL RESIDUES IN THE SOLID-PHASE SYNTHESIS OF PEPTIDES [J].
KAISER, E ;
BOSSINGER, CD ;
COLESCOTT, RL ;
OLSEN, DB .
ANALYTICA CHIMICA ACTA, 1980, 118 (01) :149-151
[17]   Electrical contacting of glucose oxidase in a redox-active rotaxane configuration [J].
Katz, E ;
Sheeney-Haj-Ichia, L ;
Willner, I .
ANGEWANDTE CHEMIE-INTERNATIONAL EDITION, 2004, 43 (25) :3292-3300
[18]  
Kohli P, 2005, CURR PHARM BIOTECHNO, V6, P35
[19]   Elaboration of a new hydrogen peroxide biosensor using microperoxidase 8 (MP8) immobilized on a polypyrrole coated electrode [J].
Korri-Youssoufi, H. ;
Desbenoit, N. ;
Ricoux, R. ;
Mahy, J. -P. ;
Lecomte, S. .
MATERIALS SCIENCE & ENGINEERING C-BIOMIMETIC AND SUPRAMOLECULAR SYSTEMS, 2008, 28 (5-6) :855-860
[20]   Direct electron transfer and electrocatalysis of microperoxidase immobilized on nanohybrid film [J].
Liu, Y ;
Wang, MK ;
Zhao, F ;
Guo, ZH ;
Chen, HJ ;
Dong, SJ .
JOURNAL OF ELECTROANALYTICAL CHEMISTRY, 2005, 581 (01) :1-10