MRI of Polyethylene Tibial Inserts in Total Knee Arthroplasty: Normal and Abnormal Appearances

被引:11
作者
Li, Angela E. [1 ,2 ]
Sneag, Darryl B. [1 ,2 ]
Miller, Theodore T. [1 ,2 ]
Lipman, Joseph D. [3 ]
Padgett, Douglas E. [2 ,4 ]
Potter, Hollis G. [1 ,2 ]
机构
[1] Hosp Special Surg, Dept Radiol & Imaging, 535 E 70th St, New York, NY 10021 USA
[2] Weill Cornell Med Coll, New York, NY USA
[3] Hosp Special Surg, Dept Biomech, 535 E 70th St, New York, NY 10021 USA
[4] Hosp Special Surg, Adult Reconstruct & Joint Replacement Div, 535 E 70th St, New York, NY 10021 USA
关键词
fracture; implant; MRI; polyethylene tibial insert; polyethylene wear; total knee arthroplasty; MICROCOMPUTED TOMOGRAPHY; WEAR; DISSOCIATION; OSTEOLYSIS; FAILURE;
D O I
10.2214/AJR.15.15107
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
OBJECTIVE. The purpose of this study was to describe the normal and abnormal MRI appearances of polyethylene tibial inserts. Subjects who underwent MRI before revision total knee arthroplasty were identified. The polyethylene tibial insert's shape was categorized on MRI, and the presence of abnormalities was noted. CONCLUSION. The shape of the polyethylene tibial insert varied with the design. Polyethylene tibial insert abnormalities seen on MRI included displacement and fracture. MRI distinguishes various designs of polyethylene tibial inserts and can show associated abnormalities.
引用
收藏
页码:1264 / 1271
页数:8
相关论文
共 30 条
[1]   Spontaneous, recurrent dislodgment of the polyethylene tibial insert after total knee arthroplasty - A case report [J].
Anderson, John A. ;
MacDessi, Samuel J. ;
Valle, Alejandro Gonzalez Della .
JOURNAL OF BONE AND JOINT SURGERY-AMERICAN VOLUME, 2007, 89A (02) :404-407
[2]  
Chen CE, 2011, J ARTHROPLASTY, V26
[3]  
COLLIER JP, 1991, CLIN ORTHOP RELAT R, P232
[4]   Clinical assessment of tibial polyethylene thickness [J].
Collier, MB ;
Jewett, BA ;
Engh, CA .
JOURNAL OF ARTHROPLASTY, 2003, 18 (07) :860-866
[5]   Two stage fracture of a polyethylene post in a 9-year-old posterior-stabilized knee prosthesis: A case report [J].
D'Angelo F. ;
Marcolli D. ;
Bulgheroni P. ;
Murena L. ;
Congiu T. ;
Cherubino P. .
Journal of Medical Case Reports, 4 (1)
[6]  
DAVIS PF, 1991, CLIN ORTHOP RELAT R, P199
[7]   Radiographically Measured Total Knee Wear is Constant and Predicts Failure [J].
Engh, Charles A., Jr. ;
Collier, Matthew B. ;
Hopper, Robert H., Jr. ;
Hatten, Kyle M. ;
Engh, Gerard A. .
JOURNAL OF ARTHROPLASTY, 2013, 28 (08) :1338-1344
[8]   Can Microcomputed Tomography Measure Retrieved Polyethylene Wear? Comparing Fixed-bearing and Rotating-platform Knees [J].
Engh, Charles A., Jr. ;
Zimmerman, Rebecca L. ;
Hopper, Robert H., Jr. ;
Engh, Gerard A. .
CLINICAL ORTHOPAEDICS AND RELATED RESEARCH, 2013, 471 (01) :86-93
[9]  
Goodman Stuart B, 2013, Instr Course Lect, V62, P201
[10]   Polyethylene wear in knee arthroplasty - A new sonographic sign [J].
Guillin, Raphael ;
Laporte, Jean-Luc ;
Sabouret, Pierre ;
Cardinal, Etienne .
JOURNAL OF ULTRASOUND IN MEDICINE, 2008, 27 (02) :275-279