What do we know about ALARA? Is our knowledge sufficient about radiation safety?

被引:11
作者
Atci, Ibrahim B. [1 ]
Yilmaz, Hakan [2 ]
Antar, Veysel [1 ]
Ozdemir, Nuriye G. [1 ]
Baran, Oguz [1 ]
Sadillioglu, Sila [3 ]
Ozel, Mehmet [3 ]
Turk, Okan [1 ]
Yaman, Mehmet [1 ]
Topacoglu, Hakan [3 ]
机构
[1] Istanbul Educ & Res Hosp, Dept Neurosurg, Istanbul, Turkey
[2] Duzce State Hosp, Dept Neurosurg, Duzce, Turkey
[3] Istanbul Educ & Res Hosp, Dept Emergency Med, Istanbul, Turkey
关键词
Tomography; X-ray computed; Brain; Radiation; Safety; COMPUTED-TOMOGRAPHY; CT; AWARENESS; CHILDREN; RISKS;
D O I
10.23736/S0390-5616.16.03418-4
中图分类号
R74 [神经病学与精神病学];
学科分类号
摘要
BACKGROUND: The aim of this study was to determine the knowledge of neurosurgeons and emergency physicians about ALARA (as low as reasonably achievable) and to gain awareness to them about this topic. METHODS: A multiple-choice survey comprising 17 questions was performed to 30 neurosurgeons and 70 emergency room doctors. RESULTS: Emergency medicine doctors, neurosurgeons, emergency medicine residents, neurosurgery residents and general practitioners participated in the survey. Sixty-six percent of participants stated that they examined more than 50 patient with headache, dizziness and head trauma in emergency service per diem and more than half of the participants stated that brain CT was performed in the event of patient's request, even if there was not an indication. 75% of the participants stated that they requested CT scan without neurological examination when the number of patients increased in the emergency room. Eighty-three percent of the participants did not think there was a safe dose limit in CT, 92% did not know the radiation dose received during brain CT, 96% did not know the meaning of the ALARA. Fifty-seven percent of the participants stated that if they informed about the criteria of ALARA, they will take into acount these criteria while requesting CT scan. CONCLUSIONS: In our country, doctors working in emergency services request brain CT needlessly because of taking into account the patient's wish and fear of malpractice. The knowledge of the neurosurgeons and emergency service doctors about ALARA is insufficient. It is necessary to educate our physicians about ALARA protocol, for taking these criteria into their consideration when requesting CT examination. For protecting the patients from the effects of ionizing radiation and reducing the economic loss of hospitals, it is necessary to increase awareness of the ALARA protocol and to increase the number of hospitals which protocol is applied.
引用
收藏
页码:597 / 602
页数:6
相关论文
共 15 条
[1]   Increase in dicentric chromosome formation after a single CT scan in adults [J].
Abe, Yu ;
Miura, Tomisato ;
Yoshida, Mitsuaki A. ;
Ujiie, Risa ;
Kurosu, Yumiko ;
Kato, Nagisa ;
Katafuchi, Atsushi ;
Tsuyama, Naohiro ;
Ohba, Takashi ;
Inamasu, Tomoko ;
Shishido, Fumio ;
Noji, Hideyoshi ;
Ogawa, Kazuei ;
Yokouchi, Hiroshi ;
Kanazawa, Kenya ;
Ishida, Takashi ;
Muto, Satoshi ;
Ohsugi, Jun ;
Suzuki, Hiroyuki ;
Ishikawa, Tetsuo ;
Kamiya, Kenji ;
Sakai, Akira .
SCIENTIFIC REPORTS, 2015, 5
[2]  
Almohiy H, 2014, WORLD J RADIOL, V6, P1, DOI 10.4329/wjr.v6.i1.1
[3]   Patient doses from CT examinations in Turkey [J].
Atac, Gokce Kaan ;
Parmaksiz, Aydin ;
Inal, Tolga ;
Bulur, Emine ;
Bulgurlu, Figen ;
Oncu, Tolga ;
Gundogdu, Sadi .
DIAGNOSTIC AND INTERVENTIONAL RADIOLOGY, 2015, 21 (05) :428-434
[4]   Mild and moderate pediatric traumatic brain injury: Replace routine repeat head computed tomography with neurologic examination [J].
Aziz, Hassan ;
Rhee, Peter ;
Pandit, Viraj ;
Ibrahim-Zada, Irada ;
Kulvatunyou, Narong ;
Wynne, Julie ;
Zangbar, Bardiya ;
O'Keeffe, Terence ;
Tang, Andrew ;
Friese, Randall S. ;
Joseph, Bellal .
JOURNAL OF TRAUMA AND ACUTE CARE SURGERY, 2013, 75 (04) :550-554
[5]   Estimated risks of radiation-induced fatal cancer from pediatric CT [J].
Brenner, DJ ;
Elliston, CD ;
Hall, EJ ;
Berdon, WE .
AMERICAN JOURNAL OF ROENTGENOLOGY, 2001, 176 (02) :289-296
[6]   Radiation risk to children from computed tomography [J].
Brody, Alan S. ;
Frush, Donald P. ;
Huda, Walter ;
Brent, Robert L. .
PEDIATRICS, 2007, 120 (03) :677-682
[7]   Practice of ALARA in the pediatric interventional suite [J].
Connolly, Bairbre ;
Racadio, John ;
Towbin, Richard .
PEDIATRIC RADIOLOGY, 2006, 36 (Suppl 2) :163-167
[8]   Minimizing radiation dose for pediatric body applications of single-detector helical CT: Strategies at a large children's hospital [J].
Donnelly, LF ;
Emery, KH ;
Brody, AS ;
Laor, T ;
Gylys-Morin, VM ;
Anton, CG ;
Thomas, SR ;
Frush, DP .
AMERICAN JOURNAL OF ROENTGENOLOGY, 2001, 176 (02) :303-306
[9]   Pediatricians' awareness of diagnostic medical radiation effects and doses: are the latest efforts paying off? [J].
Eksioglu, Ayse Secil ;
Uner, Cigdem .
DIAGNOSTIC AND INTERVENTIONAL RADIOLOGY, 2012, 18 (01) :78-86
[10]   The 'Image Gently' campaign: increasing CT radiation dose awareness through a national education and awareness program [J].
Goske, Marilyn J. ;
Applegate, Kimberly E. ;
Boylan, Jennifer ;
Butler, Penny F. ;
Callahan, Michael J. ;
Coley, Brian D. ;
Farley, Shawn ;
Frush, Donald P. ;
Hernanz-Schulman, Marta ;
Jaramillo, Diego ;
Johnson, Neil D. ;
Kaste, Sue C. ;
Morrison, Gregory ;
Strauss, Keith J. ;
Tuggle, Nora .
PEDIATRIC RADIOLOGY, 2008, 38 (03) :265-269