Investigating the performance of reflective insulation and low emissivity paints for the energy retrofit of roof attics

被引:54
作者
Fantucci, Stefano [1 ]
Serra, Valentina [1 ]
机构
[1] Politecn Torino, Dept Energy, TEBE Res Grp, Corso Duca Abruzzi 24, I-10129 Turin, Italy
关键词
Reflective insulation; Reflective paint; Low emissivity; Radiation control coatings; Roof; Attics; RADIANT BARRIERS; THERMAL PERFORMANCE; BUILDINGS; INTERIOR; COMFORT;
D O I
10.1016/j.enbuild.2018.10.003
中图分类号
TU [建筑科学];
学科分类号
0813 ;
摘要
The energy retrofitting and conversion of attic spaces into liveable dwelling units is a widely diffused practice in EU countries, and it leads to an increment in urban density, without having to construct new buildings. Roof surfaces are the parts of buildings that are exposed the most to the sun in summer season, and for this reason, they are responsible for high cooling loads, which can determine overheating phenomena in the dwellings below the attics. Different strategies that involve the use of extra-insulation or an increase in the solar reflectance of the outer layer can be adopted to resolve this problem. However, another solution that is sometimes adopted is the introduction of long-wave infra-red reflective insulations, which are generally applied below the roof tiles, facing an air cavity. This strategy allows the thermal resistance of a roof to be increased, as a result of a reduction in the radiation heat exchange, without having to increase the insulation thickness. In this study, an in-field experimental campaign has been carried out in Turin, Italy. The analysis was aimed at investigating the thermal behaviour of traditional roof adopting reflective insulation, made up of aluminium sheets, and of a new strategy, based on a treatment with low emissivity paint below the roof tiles. The experimental data were used to verify numerical ID heat transfer simulations to account for the effect of the radiation heat exchange in the airspace below the roof tiles. The verified simulation models were used to analyse the effects of the insulation levels and of the emissivity properties of the reflective layer on the roof heat exchange. A reduction in the indoor summer heat gains of between similar to 10% and similar to 53% was found for roofs treated with refective insulation, depending on their emissivity properties, while the contribution to reducing the winter heat losses was negligible. The obtained results are encouraging and highlight that reflective insulation, used together with Low E paints, represents a promising solution that can be used to help design attic retrofitting interventions, with the aim of achieving a better thermal performance in the summer period, and to address the requirements of indoor space saving. (C) 2018 Elsevier B.V. All rights reserved.
引用
收藏
页码:300 / 310
页数:11
相关论文
共 34 条
[1]   Energy and economic analysis of Vacuum Insulation Panels (VIPs) used in non-domestic buildings [J].
Alam, M. ;
Singh, H. ;
Suresh, S. ;
Redpath, D. A. G. .
APPLIED ENERGY, 2017, 188 :1-8
[2]  
American Society of Heating Refrigerating and Air Conditioning Engineers (ASHRAE), 2013, ASHRAE HDB FUND
[3]  
[Anonymous], 2007, 137862007 EN ISO
[4]  
[Anonymous], 2017, 69462017 EN ISO
[6]   Wood fiber vs synthetic thermal insulation for roofs energy retrofit: a case study in Turin, Italy [J].
Bianco, Lorenza ;
Pollo, Riccardo ;
Serra, Valentina .
8TH INTERNATIONAL CONFERENCE ON SUSTAINABILITY IN ENERGY AND BUILDINGS, SEB-16, 2017, 111 :357-366
[7]   The effects of interior emissivity and room layout on forced air space-conditioning power usage [J].
Buckmaster, David J. ;
Abramson, Alexis R. .
INTERNATIONAL JOURNAL OF HEAT AND MASS TRANSFER, 2015, 89 :216-228
[8]   Energy analysis of ventilated and microventilated roofs [J].
Ciampi, M ;
Leccese, F ;
Tuoni, G .
SOLAR ENERGY, 2005, 79 (02) :183-192
[9]  
Cook J. C., 1989, ASHRAE T, V95, P667
[10]   Effects of roof tile permeability on the thermal performance of ventilated roofs: Analysis of annual performance [J].
D'Orazio, M. ;
Di Perna, C. ;
Principi, P. ;
Stazi, A. .
ENERGY AND BUILDINGS, 2008, 40 (05) :911-916