Repeatability and Reproducibility of Retinal Neuronal and Axonal Measures on Spectral-Domain Optical Coherence Tomography in Patients with Cognitive Impairment

被引:16
|
作者
Loh, Edwin Hong-Teck [1 ]
Ong, Yi-Ting [1 ,2 ]
Venketasubramanian, Narayanaswamy [3 ,4 ]
Hilal, Saima [3 ]
Thet, Naing [5 ]
Wong, Tien Yin [1 ,2 ,5 ]
Chen, Christopher P. L. [3 ,6 ]
Cheung, Carol Yim-Lui [1 ,7 ]
机构
[1] Singapore Natl Eye Ctr, Singapore Eye Res Inst, Singapore, Singapore
[2] Natl Univ Singapore, Duke NUS Med Sch, Singapore, Singapore
[3] Natl Univ Hlth Syst, Memory Aging & Cognit Ctr, Singapore, Singapore
[4] Raffles Hosp, Raffles Neurosci Ctr, Singapore, Singapore
[5] Natl Univ Singapore, Yong Loo Lin Sch Med, Dept Ophthalmol, Singapore, Singapore
[6] Natl Univ Singapore, Dept Pharmacol, Singapore, Singapore
[7] Chinese Univ Hong Kong, Dept Ophthalmol & Visual Sci, Hong Kong, Hong Kong, Peoples R China
来源
FRONTIERS IN NEUROLOGY | 2017年 / 8卷
关键词
retina; reproducibility; repeatability; mild cognitive impairment; dementia; optical coherence tomography; NERVE-FIBER LAYER; EARLY ALZHEIMERS-DISEASE; GANGLION-CELL ANALYSIS; THICKNESS MEASUREMENTS; GLAUCOMA; VARIABILITY; ABNORMALITIES; ATROPHY; CIRRUS;
D O I
10.3389/fneur.2017.00359
中图分类号
R74 [神经病学与精神病学];
学科分类号
摘要
Background: With increasing interest in determining if measurement of retinal neuronal structure with spectral-domain optical coherence tomography (SD-OCT) is useful in accessing neurodegenerative process in cognitive decline and development of dementia, it is important to evaluate whether the SD-OCT measurements are repeatable and reproducible in these patients. Methods: This is a retrospective cohort study. Patients with Alzheimer's disease (AD) or mild cognitive impairment (MCI) with no change in global clinical dementia rating (CDR) score at 1-year follow-up were eligible to be included. Ganglion cell-inner plexiform layer (GC-IPL) and retinal nerve fiber layer (RNFL) parameters were measured with SD-OCT at baseline, 6-month, and 1-year follow-up visits. At baseline, SD-OCT scans were repeated to access intra-visit repeatability of the SD-OCT measurement. SD-OCT measurement over three visits was used to access inter-visit reproducibility. We calculated intraclass correlation coefficients (ICC) and coefficients of variation (CoVs). Results: We included 32 patients with stable AD and 29 patients with stable MCI in the final analysis. For GC-IPL measures, the average intra-visit ICC was 0.969 (range: 0.948-0.985), and CoV was 1.81% (range: 1.14-2.40); while the average inter-visit ICC was 0.968 (0.941-0.985), and CoV was 1.91% (range: 1.24-2.32). The average ICC and CoV of intra-visit RNFL measured were 0.965 (range: 0.937-0.986) and 2.32% (range: 1.34-2.90%), respectively. The average ICC and CoV of inter-visit RNFL measures were 0.927 (range: 0.845-0.961) and 3.83% (range: 2.71-5.25%), respectively. Conclusion: Both GC-IPL and RNFL measurements had good intra-visit repeatability and inter-visit reproducibility over 1 year in elderly patients with no decline in cognitive function, suggesting that SD-OCT is a reliable tool to assess neurodegenerative process over time.
引用
收藏
页数:7
相关论文
共 50 条
  • [31] Relationship between Spectral-Domain Optical Coherence Tomography and Standard Automated Perimetry in Healthy and Glaucoma Patients
    Abadia, Beatriz
    Ferreras, Antonio
    Calvo, Pilar
    Ara, Mirian
    Ferrandez, Blanca
    Otin, Sofia
    Frezzotti, Paolo
    Pablo, Luis E.
    Figus, Michele
    BIOMED RESEARCH INTERNATIONAL, 2014, 2014
  • [33] Three-dimensional segmentation and reconstruction of the retinal vasculature from spectral-domain optical coherence tomography
    Guimaraes, Pedro
    Rodrigues, Pedro
    Celorico, Dirce
    Serranho, Pedro
    Bernardes, Rui
    JOURNAL OF BIOMEDICAL OPTICS, 2015, 20 (01)
  • [34] Evaluation of anterior chamber parameters with spectral-domain optical coherence tomography
    Pinilla Lozano, Isabel
    Lopez de la Fuente, Carmen
    Segura, Francisco
    Orduna Hospital, Elvira
    Sanchez-Cano, Ana
    JAPANESE JOURNAL OF OPHTHALMOLOGY, 2018, 62 (02) : 209 - 215
  • [35] Spectral-domain Optical Coherence Tomography Retinal and Choroidal Thickness Metric Repeatability in Age-related Macular Degeneration
    Hanumunthadu, Daren
    Ilginis, Tomas
    Restori, Marie
    Sagoo, Mandeep
    Tufail, Adnan
    Balaggan, Kamaljit S.
    Patel, Praveen J.
    AMERICAN JOURNAL OF OPHTHALMOLOGY, 2016, 166 : 154 - 161
  • [36] Reproducibility of Retinal Nerve Fiber Layer Thickness Measurements Using Spectral Domain Optical Coherence Tomography
    Wu, Huijuan
    de Boer, Johannes F.
    Chen, Teresa C.
    JOURNAL OF GLAUCOMA, 2011, 20 (08) : 470 - 476
  • [37] Effect of head tilt on repeatability of optic nerve head parameters using Cirrus spectral-domain optical coherence tomography
    Koh, Lilian Hui Li
    Ismail, Muhammad Amir
    Yap, Sae Cheong
    Wong, Elizabeth Poh Ying
    Yip, Leonard Wei Leon
    INTERNATIONAL JOURNAL OF OPHTHALMOLOGY, 2016, 9 (08) : 1170 - 1175
  • [38] Spectral-domain optical coherence tomography findings of tractional retinal elevation in patients with diabetic retinopathy
    Kim, Yu Cheol
    Shin, Jae Pil
    GRAEFES ARCHIVE FOR CLINICAL AND EXPERIMENTAL OPHTHALMOLOGY, 2016, 254 (08) : 1481 - 1487
  • [39] Spectral-domain optical coherence tomography findings of tractional retinal elevation in patients with diabetic retinopathy
    Yu Cheol Kim
    Jae Pil Shin
    Graefe's Archive for Clinical and Experimental Ophthalmology, 2016, 254 : 1481 - 1487
  • [40] Spectral-domain optical coherence tomography finding of acute retinal pigment epitheliitis
    Li, Yi-Hsuan
    Chang, Yo-Chen
    Wu, Wen-Chuan
    TAIWAN JOURNAL OF OPHTHALMOLOGY, 2019, 9 (04) : 276 - 279