Analyses of polychlorinated biphenyls in waters and wastewaters using vortex-assisted liquid-liquid microextraction and gas chromatography-mass spectrometry

被引:51
作者
Ozcan, Senar [1 ]
机构
[1] Selcuk Univ, Dept Environm Engn, TR-42031 Konya, Turkey
关键词
Factorial design; Polychlorinated biphenyls; Vortex-assisted liquid-liquid microextraction; Wastewater; Water; SOLID-PHASE MICROEXTRACTION; BAR SORPTIVE EXTRACTION; POLYCYCLIC AROMATIC-HYDROCARBONS; SINGLE-DROP; EMULSIFICATION-MICROEXTRACTION; SOLVENT-EXTRACTION; ORGANIC POLLUTANTS; KONYA-TURKEY; WASTE-WATER; SAMPLES;
D O I
10.1002/jssc.201000623
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
A method was developed for viable and rapid determination of seven polychlorinated biphenyls (PCBs) in water samples with vortex-assisted liquid-liquid microextraction (VALLME) using gas chromatography-mass spectrometry (GC-MS). At first, the most suitable extraction solvent and extraction solvent volume were determined. Later, the parameters affecting the extraction efficiency such as vortex extraction time, rotational speed of the vortex, and ionic strength of the sample were optimized by using a 2(3) factorial experimental design. The optimized extraction conditions for 5 mL water sample were as follows: extractant solvent 200 mu L of chloroform; vortex extraction time of 2 min at 3000 rpm; centrifugation 5 min at 4000 rpm, and no ionic strength. Under the optimum condition, limits of detection (LOD) ranged from 0.36 to 0.73 ng/L. Mean recoveries of PCBs from fortified water samples are 96% for three different fortification levels and RSDs of the recoveries are below 5%. The developed procedure was successfully applied to the determination of PCBs in real water and wastewater samples such as tap, well, surface, bottled waters, and municipal, treated municipal, and industrial wastewaters. The performance of the proposed method was compared with traditional liquid-liquid extraction (LLE) of real water samples and the results show that efficiency of proposed method is comparable to the LLE. However, the proposed method offers several advantages, i.e. reducing sample requirement for measurement of target compounds, less solvent consumption, and reducing the costs associated with solvent purchase and waste disposal. It is also viable, rapid, and easy to use for the analyses of PCBs in water samples by using GC-MS.
引用
收藏
页码:574 / 584
页数:11
相关论文
共 48 条
[1]  
[Anonymous], 2005, TURKISH OFFICIAL GAZ
[2]  
[Anonymous], 2003, WHO Concise International Chemical Assessment Document 55, Polychlorinated Biphenyls: Human Health Aspects
[3]  
[Anonymous], 2000, ATSDR TOXICOLOGICAL
[4]  
[Anonymous], 2005, Standards methods for the examination of water and wastewater, V21
[5]  
Aydin ME, 2004, FRESEN ENVIRON BULL, V13, P118
[6]   On-site polymer-coated hollow fiber membrane microextraction and gas chromatography-mass spectrometry of polychlorinated biphenyls and polybrominated diphenyl ethers [J].
Basheer, Chanbasha ;
Vetrichelvan, Muthalagu ;
Valiyaveettil, Suresh ;
Lee, Hian Kee .
JOURNAL OF CHROMATOGRAPHY A, 2007, 1139 (02) :157-164
[7]  
BOURGEOIS DJ, 1994, INT J ENVIRON AN CH, V59, P15
[8]   Phytoremediation of polychlorinated biphenyl-contaminated soils: the rhizosphere effect [J].
Chekol, T ;
Vough, LR ;
Chaney, RL .
ENVIRONMENT INTERNATIONAL, 2004, 30 (06) :799-804
[9]   MultiSimplex optimisation of the solid-phase microextraction-gas chromatographic-mass spectrometric determination of polycyclic aromatic hydrocarbons, polychlorinated biphenyls and phthalates from water samples [J].
Cortazar, E ;
Zuloaga, O ;
Sanz, J ;
Raposo, JC ;
Etxebarria, N ;
Fernández, LA .
JOURNAL OF CHROMATOGRAPHY A, 2002, 978 (1-2) :165-175
[10]   Dispersive liquid-liquid microextraction based on the solidification of floating organic droplet for the determination of polychlorinated biphenyls in aqueous samples [J].
Dai, Liping ;
Cheng, Jing ;
Matsadiq, Guzalnur ;
Liu, Lu ;
Li, Jun-Kai .
ANALYTICA CHIMICA ACTA, 2010, 674 (02) :201-205