Automatic flow delay through passive wax valves for paper-based analytical devices

被引:11
作者
Meng, Haixu [1 ]
Chen, Chang [1 ,2 ]
Zhu, Yonggang [1 ]
Li, Zhengtu [3 ]
Ye, Feng [3 ]
Ho, Joshua W. K. [4 ]
Chen, Huaying [1 ]
机构
[1] Harbin Inst Technol, Sch Mech Engn & Automat, Shenzhen 518055, Peoples R China
[2] Wageningen Univ & Res, Lab Phys Chem & Soft Matter, Stippeneng 4, NL-6708 WE Wageningen, Netherlands
[3] Guangzhou Med Univ, Affiliated Hosp 1, Natl Clin Ctr Resp Dis, Guangzhou Inst Resp Hlth,State Key Lab Resp Dis, Guangzhou 510120, Peoples R China
[4] Univ Hong Kong, Li Ka Shing Fac Med, Sch Biomed Sci, Hong Kong, Peoples R China
基金
中国国家自然科学基金;
关键词
POLY(DIMETHYLSILOXANE) BARRIERS; MICROFLUIDICS; ASSAYS; FABRICATION; BIOSENSOR; PLATFORM; CONTACT;
D O I
10.1039/d1lc00638j
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
Microfluidic paper-based analytical devices (mu PADs) have been widely explored for point-of-care testing due to their simplicity, low cost, and portability. mu PADs with multiple-step reactions usually require precise flow control, especially flow-delay. This paper reports the numerical, mathematical, and experimental studies of flow delay through wax valves surrounded by PDMS walls on paper microfluidics. The predried surfactant in the sample zone diffuses into the liquid sample which can therefore flow through the wax valves. The delay time is automatically regulated by the diffusion of the surfactant after sample loading. The numerical study suggested that both the elevated contact angle and the reduced porosity and pore size in the wax printed region could effectively prevent water but allow liquids with lower contact angles (e.g., surfactant solutions) to flow through. The PDMS walls fabricated using a low-cost liquid dispenser effectively prevented the leakage of surfactant solutions. By controlling the quantity, diffusion distance, and type of the surfactant predried on the chip, the system successfully achieved a delay time ranging from 1.6 to 20 minutes. A mathematical model involving the above parameters was developed based on Fick's second law to predict the delay time. Finally, the flow-delay systems were applied in sequential mixing and distance-based detection of either glucose or alcohol. Linear ranges of 1-100 mg dL(-1) and 1-40 mg dL(-1) were achieved for glucose and alcohol, respectively. The lower limit detection (LOD) of glucose and alcohol was 1 mg dL(-1). The LOD of glucose was only 1/11 of that detected using mu PADs without flow control, indicating the advantage of controlling fluid flow. The systematic findings in this study provide critical guidelines for the development and applications of wax valves in automatic flow delay for point-of-care testing.
引用
收藏
页码:4166 / 4176
页数:11
相关论文
共 54 条
[1]   Fluidic flow delay by ionogel passive pumps in microfluidic paper-based analytical devices [J].
Akyazi, Tugce ;
Saez, Janire ;
Elizalde, Jorge ;
Benito-Lopez, Fernando .
SENSORS AND ACTUATORS B-CHEMICAL, 2016, 233 :402-408
[2]   Distance-based paper microfluidics; principle, technical aspects and applications [J].
Alsaeed, Basma ;
Mansour, Fotouh R. .
MICROCHEMICAL JOURNAL, 2020, 155
[3]   Development of automated paper-based devices for sequential multistep sandwich enzyme-linked immunosorbent assays using inkjet printing [J].
Apilux, Amara ;
Ukita, Yoshiaki ;
Chikae, Miyuki ;
Chailapakul, Orawon ;
Takamura, Yuzuru .
LAB ON A CHIP, 2013, 13 (01) :126-135
[4]   Low-cost printing of poly(dimethylsiloxane) barriers to define microchannels in paper [J].
Bruzewicz, Derek A. ;
Reches, Meital ;
Whitesides, George M. .
ANALYTICAL CHEMISTRY, 2008, 80 (09) :3387-3392
[5]   Understanding Wax Printing: A Simple Micropatterning Process for Paper-Based Microfluidics [J].
Carrilho, Emanuel ;
Martinez, Andres W. ;
Whitesides, George M. .
ANALYTICAL CHEMISTRY, 2009, 81 (16) :7091-7095
[6]   Simple, distance-based measurement for paper analytical devices [J].
Cate, David M. ;
Dungchai, Wijitar ;
Cunningham, Josephine C. ;
Volckens, John ;
Henry, Charles S. .
LAB ON A CHIP, 2013, 13 (12) :2397-2404
[7]   Novel Wax Valves To Improve Distance-Based Analyte Detection in Paper Microfluidics [J].
Chen, Chang ;
Zhao, Litao ;
Zhang, Han ;
Shen, Xiaoshuang ;
Zhu, Yonggang ;
Chen, Huaying .
ANALYTICAL CHEMISTRY, 2019, 91 (08) :5169-5175
[8]  
Chen CC, 2015, IEEE ENG MED BIO, P5892, DOI 10.1109/EMBC.2015.7319732
[9]   A fluidic diode, valves, and a sequential-loading circuit fabricated on layered paper [J].
Chen, Hong ;
Cogswell, Jeremy ;
Anagnostopoulos, Constantine ;
Faghri, Mohammad .
LAB ON A CHIP, 2012, 12 (16) :2909-2913
[10]   A paper-based nanomodified electrochemical biosensor for ethanol detection in beers [J].
Cinti, Stefano ;
Basso, Mattia ;
Moscone, Danila ;
Arduini, Fabiana .
ANALYTICA CHIMICA ACTA, 2017, 960 :123-130