Evaluation of Two Types of Intramedullary Jones Fracture Fixation in a Cyclic and Ultimate Load Model

被引:9
|
作者
Willegger, Madeleine [1 ]
Benca, Emir [1 ]
Hirtler, Lena [2 ]
Kasparek, Maximilian F. [1 ]
Bauer, Gregor [1 ]
Zandieh, Shahin [3 ]
Windhager, Reinhard [1 ]
Schuh, Reinhard [1 ]
机构
[1] Med Univ Vienna, Dept Orthoped & Trauma Surg, Div Orthoped, Vienna, Austria
[2] Med Univ Vienna, Ctr Anat & Cell Biol, Div Anat, Vienna, Austria
[3] Hanusch Hosp, Dept Radiol & Nucl Med, Vienna, Austria
关键词
Jones fracture; intramedullary screw; fracture-specific screw; headless compression screw; bone mineral density; SCREW FIXATION; 5TH-METATARSAL; OUTCOMES; ATHLETE; RETURN;
D O I
10.1002/jor.24530
中图分类号
R826.8 [整形外科学]; R782.2 [口腔颌面部整形外科学]; R726.2 [小儿整形外科学]; R62 [整形外科学(修复外科学)];
学科分类号
摘要
Implant choice is a matter of concern in athletes and active patients who sustain a Jones fracture because they are prone to failure including non-union, screw failure, and refracture. The aim of this study was to compare the biomechanical behavior of a Jones fracture-specific screw (JFXS) with a cannulated headless compression screw (HCS) in a simulated partial weight-bearing and ultimate load Jones fracture fixation model. Ten matched pairs of human anatomical specimens underwent Jones fracture creation and consecutive intramedullary stabilization with a solid JFXS or a cannulated HCS. The bone mineral density was assessed prior to testing. Cyclic plantar to dorsal loading was applied for 1000 cycles, followed by load to failure testing. Angulation was measured by an opto-electronic motion capture system and mode of failure classification was determined by video analysis. Paired analysis showed no statistically significant difference between both screw constructs. Ultimate load reached 236.9 +/- 107.8 N in the JFXS group compared with 210.8 +/- 150.7 N in the HCS group (p = 0.429). The bone mineral density correlated positive with the pooled ultimate load (R = 0.580, p = 0.007) for all constructs and negatively with angulation (R = -0.680, p = 0.002) throughout cyclic loading. Solid fracture-specific and cannulated headless compression screws provide equal ultimate loads and stiffness for Jones fracture fixation. A low bone mineral density significantly impairs the construct stability and the ultimate load of both intramedullary screw constructs. (c) 2019 The Authors. Journal of Orthopaedic Research (R) published by Wiley Periodicals, Inc. on behalf of Orthopaedic Research Society J Orthop Res 38:911-917, 2020
引用
收藏
页码:911 / 917
页数:7
相关论文
共 13 条
  • [1] A New Option for Intramedullary Fixation of Jones Fractures: The Charlotte™ Carolina™ Jones Fracture System
    Nunley, James A., II
    Glisson, Richard R.
    FOOT & ANKLE INTERNATIONAL, 2008, 29 (12) : 1216 - 1221
  • [2] Four Cases with Rare Complications of Intramedullary Screw Fixation for Jones Fracture
    Morimoto, Yusuke
    Komatsu, Taichi
    Tokuhashi, Yasuaki
    ACTA MEDICA OKAYAMA, 2020, 74 (06) : 537 - 544
  • [3] Closed Intramedullary Screw Fixation for Nonunion of Fifth Metatarsal Jones Fracture
    Habbu, Rohan A.
    Marsh, Robert S.
    Anderson, John G.
    Bohay, Donald R.
    FOOT & ANKLE INTERNATIONAL, 2011, 32 (06) : 603 - 608
  • [4] Biomechanical Comparison of Intramedullary Screw Versus Low-Profile Plate Fixation of a Jones Fracture
    Huh, Jeannie
    Glisson, Richard R.
    Matsumoto, Takumi
    Easley, Mark E.
    FOOT & ANKLE INTERNATIONAL, 2016, 37 (04) : 411 - 418
  • [5] Radiographic Study of the Fifth Metatarsal for Optimal Intramedullary Screw Fixation of Jones Fracture
    Ochenjele, George
    Ho, Bryant
    Switaj, Paul J.
    Fuchs, Daniel
    Goyal, Nitin
    Kadakia, Anish R.
    FOOT & ANKLE INTERNATIONAL, 2015, 36 (03) : 293 - 301
  • [6] Treatment of Jones Fracture Nonunions and Refractures in the Elite Athlete Outcomes of Intramedullary Screw Fixation With Bone Grafting
    Hunt, Kenneth J.
    Anderson, Robert B.
    AMERICAN JOURNAL OF SPORTS MEDICINE, 2011, 39 (09) : 1948 - 1954
  • [7] Return to Weightbearing and High-Impact Activities Following Jones Fracture Intramedullary Screw Fixation
    Bucknam, Ryan B.
    Scanaliato, John P.
    Kusnezov, Nicholas A.
    Heida, Kenneth A., Jr.
    Dunn, John C.
    Orr, Justin D.
    FOOT & ANKLE INTERNATIONAL, 2020, 41 (04) : 379 - 386
  • [8] Intramedullary Impaction of the Basicervical Component Is Determinant of Fixation Failure in a Simple Two-Part Pertrochanteric Fracture
    Hong, Seok Ha
    Yu, Kang Hun
    Han, Seung Beom
    JOURNAL OF ORTHOPAEDIC TRAUMA, 2024, 38 (04) : 220 - 226
  • [9] Iatrogenic fracture gapping during fixation of Jones fractures: Anatomic and mechanical considerations in a cadaveric model
    Kaiser, Philip B.
    Riedel, Matthew D.
    Qudsi, Rameez A.
    Ghorbanhoseini, Mohammad
    Kwon, John Y.
    INJURY-INTERNATIONAL JOURNAL OF THE CARE OF THE INJURED, 2018, 49 (08): : 1485 - 1490
  • [10] Fifth metatarsal Jones fracture fixation with a 4.5-mm cannulated stainless steel screw in the competitive and recreational athlete - A clinical and radiographic evaluation
    Porter, DA
    Duncan, M
    Meyer, SJF
    AMERICAN JOURNAL OF SPORTS MEDICINE, 2005, 33 (05) : 726 - 733