Transient analysis of a condensation experiment in the noncondensable gas-filled closed loop using an inverted U-tube

被引:11
作者
Choi, CJ
Lee, SY
机构
[1] Korea Atomic Energy Research Inst, Taejon, Korea, Republic of
关键词
D O I
10.1016/0306-4549(96)00005-9
中图分类号
TL [原子能技术]; O571 [原子核物理学];
学科分类号
0827 ; 082701 ;
摘要
Two-phase transient phenomena in the noncondensable gas-filled closed loop was investigated numerically using the RELAP5/MOD3 code. Analyses for three different modes observed in the inverted U-tube experiment, i.e., reflux condensation, natural circulation, and oscillatory mode between these two modes were performed. Major thermal-hydraulic phenomena were predicted well, however, system pressure and pressure drop at the U-tube riser side were overpredicted than experimental data. Higher frequent flow oscillation than the data was also predicted. Copyright (C) 1996 Elsevier Science Ltd
引用
收藏
页码:1179 / 1188
页数:10
相关论文
共 8 条
[1]  
CARSON KE, 1990, NUREGCR5535
[2]  
DEHBI AA, 1990, MITANPTR004
[3]   ANALYSIS OF EXPERIMENTS FOR STEAM CONDENSATION IN THE PRESENCE OF NONCONDENSABLE GASES USING THE RELAP5 MOD3 CODE [J].
HASSAN, YA ;
RAJA, LL .
NUCLEAR TECHNOLOGY, 1993, 104 (01) :76-88
[4]  
HEIN D, 1982, P 7 INT HEAT TRANSF
[5]  
NAKAMURA H., 1992, ASME FED, P9
[6]  
Nguyen Q., 1984, NP3471 EPRI
[7]  
VIEROW KM, 1992, SEM 2 PHAS FLOW DYN
[8]   EVALUATION OF THE LOSS OF RESIDUAL HEAT REMOVAL SYSTEMS IN PRESSURIZED WATER-REACTORS WITH U-TUBE STEAM-GENERATORS [J].
WARD, LW .
NUCLEAR TECHNOLOGY, 1992, 100 (01) :25-38