Optimization of gadodiamide concentration for MR arthrography at 3 T

被引:29
作者
Masi, JN [1 ]
Newitt, D [1 ]
Sell, CA [1 ]
Daldrup-Link, H [1 ]
Steinbach, L [1 ]
Majumdar, S [1 ]
Link, TM [1 ]
机构
[1] Univ Calif San Francisco, Dept Radiol, San Francisco, CA 94143 USA
关键词
D O I
10.2214/ajr.184.6.01841754
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
OBJECTIVE. The purpose of our study was to determine the optimal concentration of a gadolinium-based contrast agent (gadodiamide) for direct MR arthrography at 3 T compared with 1.5 T in an in vitro study. CONCLUSION. Optimized concentrations of gadolinium-based contrast agents for MR arthrography are similar at 3 and 1.5 T, although a slightly greater dilution may be useful at 3 T. Signal-to-noise ratio peak levels are significantly reduced by adding an iodinated contrast agent, relatively significantly more at 3 T than at 1.5 T.
引用
收藏
页码:1754 / 1761
页数:8
相关论文
共 28 条
[1]   Direct MR arthrography of the wrist-value in detecting complete and partial defects of intrinsic ligaments and the TFCC in comparison with arthroscopy [J].
Braun, H ;
Kenn, W ;
Schneider, S ;
Graf, M ;
Sandstede, J ;
Hahn, D .
ROFO-FORTSCHRITTE AUF DEM GEBIET DER RONTGENSTRAHLEN UND DER BILDGEBENDEN VERFAHREN, 2003, 175 (11) :1515-1524
[2]   Is a mixture of gadolinium and iodinated contract material safe during MR arthrography? [J].
Brown, RR ;
Clarke, DW ;
Daffner, RH .
AMERICAN JOURNAL OF ROENTGENOLOGY, 2000, 175 (04) :1087-1090
[3]  
CHUNG CB, 2000, MAGN RESON IMAGING C, V12, P25
[4]   Using abduction and external rotation of the shoulder to increase the sensitivity of MR arthrography in revealing tears of the anterior glenoid labrum [J].
Cvitanic, O ;
Tirman, PFJ ;
Feller, JF ;
Bost, FW ;
Minter, J ;
Carroll, KW .
AMERICAN JOURNAL OF ROENTGENOLOGY, 1997, 169 (03) :837-844
[5]  
Czerny C, 2002, RADIOLOGE, V42, P451, DOI 10.1007/s00117-002-0751-0
[6]   MR arthrography of the adult acetabular capsular-labral complex: Correlation with surgery and anatomy [J].
Czerny, C ;
Hofmann, S ;
Urban, M ;
Tschauner, C ;
Neuhold, A ;
Pretterklieber, M ;
Recht, MP ;
Kramer, J .
AMERICAN JOURNAL OF ROENTGENOLOGY, 1999, 173 (02) :345-349
[7]   Direct MR arthrography: A review of current use [J].
Grainger, AJ ;
Elliott, JM ;
Campbell, RSD ;
Tirman, PFJ ;
Steinbach, LS ;
Genant, HK .
CLINICAL RADIOLOGY, 2000, 55 (03) :163-175
[8]   MR arthrography: A review of current technique and applications [J].
Helgason, JW ;
Chandnani, VP ;
Yu, JS .
AMERICAN JOURNAL OF ROENTGENOLOGY, 1997, 168 (06) :1473-1480
[9]   Aids to successful shoulder arthrography performed with a fluoroscopically guided anterior approach [J].
Jacobson, JA ;
Lin, J ;
Jamadar, DA ;
Hayes, CW .
RADIOGRAPHICS, 2003, 23 (02) :373-378
[10]   MR ARTHROGRAPHY OF THE SHOULDER WITH GADOPENTETATE DIMEGLUMINE - INFLUENCE OF CONCENTRATION, IODINATED CONTRAST MATERIAL, AND TIME ON SIGNAL INTENSITY [J].
KOPKA, L ;
FUNKE, M ;
FISCHER, U ;
KEATING, D ;
OESTMANN, J ;
GRABBE, E .
AMERICAN JOURNAL OF ROENTGENOLOGY, 1994, 163 (03) :621-623