Decoupled fluorescence Monte Carlo model for direct computation of fluorescence in turbid media

被引:7
|
作者
Luo, Zhaoyang [1 ,2 ]
Deng, Yong [1 ,2 ]
Wang, Kan [1 ,2 ]
Lian, Lichao [1 ,2 ]
Yang, Xiaoquan [1 ,2 ]
Luo, Qingming [1 ,2 ]
机构
[1] Huazhong Univ Sci & Technol, Britton Chance Ctr Biomed Photon, Wuhan Natl Lab Optoelect, Wuhan 430074, Peoples R China
[2] Huazhong Univ Sci & Technol, Dept Biomed Engn, MoE Key Lab Biomed Photon, Minist Educ, Wuhan 430074, Peoples R China
关键词
biomedical optics; Monte Carlo simulation; fluorescence; absorption; scattering; turbid media; TIME-RESOLVED FLUORESCENCE; DIFFUSE OPTICAL TOMOGRAPHY; PHOTON MIGRATION; LIGHT-PROPAGATION; SIMULATION; TISSUE; RECONSTRUCTION; EQUATION;
D O I
10.1117/1.JBO.20.2.025002
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
We present a decoupled fluorescence Monte Carlo (dfMC) model for the direct computation of the fluorescence in turbid media. By decoupling the excitation-to-emission conversion and transport process of the fluorescence from the path probability density function and associating the corresponding parameters involving the fluorescence process with the weight function, the dfMC model employs the path histories of the excitation photons and the corresponding new weight function to directly calculate the fluorescence. We verify the model's accuracy using phantom experiments and compare it with that of the perturbation fluorescence Monte Carlo model. The results indicate that the model is accurate for the direct fluorescence calculation and, thus, has great potential for application in fluorescence-based in vivo tomography. (C) The Authors. Published by SPIE
引用
收藏
页数:10
相关论文
共 50 条
  • [1] Direct Monte Carlo computation of time-resolved fluorescence in heterogeneous turbid media
    Kumar, Anand T. N.
    OPTICS LETTERS, 2012, 37 (22) : 4783 - 4785
  • [2] Accurate quantification of fluorescent targets within turbid media based on a decoupled fluorescence Monte Carlo model
    Deng, Yong
    Luo, Zhaoyang
    Jiang, Xu
    Xie, Wenhao
    Luo, Qingming
    OPTICS LETTERS, 2015, 40 (13) : 3129 - 3132
  • [3] Monte-Carlo-based model for the extraction of intrinsic fluorescence from turbid media
    Palmer, Gregory M.
    Ramanujam, Nirmala
    JOURNAL OF BIOMEDICAL OPTICS, 2008, 13 (02)
  • [4] Monte Carlo characterization of parallelized fluorescence confocal systems imaging in turbid media
    Tanbakuchi, Anthony A.
    Rouse, Andrew R.
    Gmitro, Arthur F.
    JOURNAL OF BIOMEDICAL OPTICS, 2009, 14 (04)
  • [5] Drug quantification in turbid media by fluorescence imaging combined with light-absorption correction using white Monte Carlo simulations
    Xie, Haiyan
    Liu, Haichun
    Svenmarker, Pontus
    Axelsson, Johan
    Xu, Can T.
    Graefe, Susanna
    Lundeman, Jesper Holm
    Cheng, Haynes Pak Hay
    Svanberg, Sune
    Bendsoe, Niels
    Andersen, Peter E.
    Svanberg, Katarina
    Andersson-Engels, Stefan
    JOURNAL OF BIOMEDICAL OPTICS, 2011, 16 (06)
  • [6] Monte Carlo modelling of fluorescence in semi-infinite turbid media
    Ong, Yi Hong
    Finlay, Jarod C.
    Zhu, Timothy C.
    OPTICAL INTERACTIONS WITH TISSUE AND CELLS XXIX, 2018, 10492
  • [7] Intrinsic fluorescence of protein in turbid media using empirical relation based on Monte Carlo lookup table
    Einstein, Gnanatheepam
    Udayakumar, Kanniyappan
    Aruna, Prakasarao
    Ganesan, Singaravelu
    DYNAMICS AND FLUCTUATIONS IN BIOMEDICAL PHOTONICS XIV, 2017, 10063
  • [8] Evaluation of path-history-based fluorescence Monte Carlo method for photon migration in heterogeneous media
    Jiang, Xu
    Deng, Yong
    Luo, Zhaoyang
    Wang, Kan
    Lian, Lichao
    Yang, Xiaoquan
    Meglinski, Igor
    Luo, Qingming
    OPTICS EXPRESS, 2014, 22 (26): : 31948 - 31965
  • [9] Hybrid Monte Carlo simulation with ray tracing for fluorescence measurements in turbid media
    Lee, Seung Yup
    Mycek, Mary-Ann
    OPTICS LETTERS, 2018, 43 (16) : 3846 - 3849
  • [10] Monte Carlo simulation of multiphoton fluorescence microscopic imaging through inhomogeneous tissuelike turbid media
    Deng, XY
    Gan, XS
    Gu, M
    JOURNAL OF BIOMEDICAL OPTICS, 2003, 8 (03) : 440 - 449