摘要
Noise properties, the signal-to-noise ratio (SNR), contrast-to-noise ratio (CNR), and signal responses were compared during functional activation of the human brain at 1.5 and 3.0 T. At the higher field spiral gradient-echo (GRE) brain images revealed an average gain in SNR of 1.7 in fully relaxed and 2.2 in images with a repetition time (TR) of 1.5 sec. The tempered gain at longer Tps reflects the fact that the physiological noise depends on the signal strength acid becomes a larger fraction of the total noise at 3.0 T, Activation of the primary motor and visual cortex resulted in a 36% and 44% increase of "activated pixels" at 3.0 T, which reflects a greater sensitivity for the detection of activated gray matter at the higher field, The gain in the CNR exhibited a dependency on the underlying tissue, i.e., an Increase of 1.8x in regions of particular high activation-induced signal changes (presumably venous vessels) and of 2.2x in the average activated areas. These results demonstrate that 3.0 T provides a clear advantage over 1.5 T for neuroimaging of homogeneous brain tissue, although stronger physiological noise contributions, more complicated signal features in the proximity of strong susceptibility gradients, and changes In the intrinsic relaxation times may mediate the enhancement. Magn Reson Med 45:595-604, 2001, (C) 2001 Wiley-Liss, Inc.
引用
收藏
页码:595 / 604
页数:10
相关论文
共 50 条
  • [31] Higher sensitivity in the detection of inflammatory brain lesions in patients with clinically isolated syndromes suggestive of multiple sclerosis using high field MRI: an intraindividual comparison of 1.5 T with 3.0 T
    Mike P. Wattjes
    Götz G. Lutterbey
    Michael Harzheim
    Jürgen Gieseke
    Frank Träber
    Luisa Klotz
    Thomas Klockgether
    Hans H. Schild
    European Radiology, 2006, 16 : 2067 - 2073
  • [32] Neuroimaging brainstem circuitry supporting cardiovagal response to pain: a combined heart rate variability/ultrahigh-field (7 T) functional magnetic resonance imaging study
    Sclocco, Roberta
    Beissner, Florian
    Desbordes, Gaelle
    Polimeni, Jonathan R.
    Wald, Lawrence L.
    Kettner, Norman W.
    Kim, Jieun
    Garcia, Ronald G.
    Renvall, Ville
    Bianchi, Anna M.
    Cerutti, Sergio
    Napadow, Vitaly
    Barbieri, Riccardo
    PHILOSOPHICAL TRANSACTIONS OF THE ROYAL SOCIETY A-MATHEMATICAL PHYSICAL AND ENGINEERING SCIENCES, 2016, 374 (2067):
  • [33] T1 magnetic resonance imaging head segmentation for diffuse optical tomography and electroencephalography
    Perdue, Katherine L.
    Diamond, Solomon G.
    JOURNAL OF BIOMEDICAL OPTICS, 2014, 19 (02)
  • [34] Magnetic resonance imaging T1 indices of the brain as biomarkers of inhaled manganese exposure
    Jensen, N.
    Terrell, R.
    Ramoju, S.
    Shilnikova, N.
    Farhat, N.
    Karyakina, N.
    Cline, B. H.
    Momoli, F.
    Mattison, D.
    Krewski, D.
    CRITICAL REVIEWS IN TOXICOLOGY, 2022, 52 (05) : 358 - 370
  • [35] Neuroimaging studies of resting-state functional magnetic resonance imaging in eating disorders
    Chen, Xiong
    Ai, Chunqi
    Liu, Zhongchun
    Wang, Gang
    BMC MEDICAL IMAGING, 2024, 24 (01):
  • [36] Neuroimaging studies of brain activation for language, with an emphasis on functional magnetic resonance imaging: A review
    Kent, RD
    FOLIA PHONIATRICA ET LOGOPAEDICA, 1998, 50 (06) : 291 - 304
  • [37] Effect of Physiological Noise on Thoracolumbar Spinal Cord Functional Magnetic Resonance Imaging in 3T Magnetic Field
    Dehghani, Hamed
    Oghabian, Mohammad Ali
    Batouli, Seyed Amir Hosein
    Kheradmand, Jalil Arab
    Khatibi, Ali
    BASIC AND CLINICAL NEUROSCIENCE, 2020, 11 (06) : 737 - 751
  • [38] Quantification of Gd-DTPA concentration in neuroimaging using T1 3D MP-RAGE sequence at 3.0 T
    Xu, Fangjingwei
    Han, Hongbin
    Zhang, Hailong
    Pi, Jincai
    Fu, Yu
    MAGNETIC RESONANCE IMAGING, 2011, 29 (06) : 827 - 834
  • [39] Hippocampal profiling: Localized magnetic resonance imaging volumetry and T2 relaxometry for hippocampal sclerosis
    Vos, Sjoerd B.
    Winston, Gavin P.
    Goodkin, Olivia
    Pemberton, Hugh G.
    Barkhof, Frederik
    Prados, Ferran
    Galovic, Marian
    Koepp, Matthias
    Ourselin, Sebastien
    Cardoso, M. Jorge
    Duncan, John S.
    EPILEPSIA, 2020, 61 (02) : 297 - 309
  • [40] Sources of functional magnetic resonance imaging signal fluctuations in the human brain at rest: a 7 T study
    Bianciardi, Marta
    Fukunaga, Masaki
    van Gelderen, Peter
    Horovitz, Silvina G.
    de Zwart, Jacco A.
    Shmueli, Karin
    Duyn, Jeff H.
    MAGNETIC RESONANCE IMAGING, 2009, 27 (08) : 1019 - 1029