Sensitive electrochemical detection of toxic nitro-phenol in real environmental samples using enzymeless oxidized-carboxymethyl cellulose-sulfate/sulfated polyaniline composite based electrode

被引:8
作者
Alamry, Khalid A. [1 ]
Khan, Ajahar [1 ]
Hussein, Mahmoud A. [1 ]
Alfaifi, Sulaiman Y. [1 ]
机构
[1] King Abdulaziz Univ, Fac Sci, Dept Chem, Jeddah 21589, Saudi Arabia
关键词
Oxidized-CMC-sulfate; Sulfonated-Pani; Electrochemical sensor; Nitro-phenol detection; Bio-composite; REDUCED GRAPHENE OXIDE; SULFONATED POLYANILINE; VOLTAMMETRIC DETERMINATION; FILM ELECTRODES; O-NITROPHENOL; NANOCOMPOSITE; 4-NITROPHENOL; NANOPARTICLES; 2-NITROPHENOL; NANOSTRUCTURES;
D O I
10.1016/j.microc.2021.106902
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
In current study, sulfated-polyaniline and oxidized-sulfated-carboxymethyl cellulose (S-Pani/Ox/CMCS) deposited on a glassy carbon electrode (GCE) was investigated in a mediator-free, non-enzymatic electrochemical sensing for ortho-nitrophenol (2-NP). The resulting S-Pani/Ox/CMCS bio-composites were analyzed by scanning electron microscopy, X-ray diffraction, Fourier transform infrared spectroscopy, transmission electron microscopy, and X-ray photoelectron. The electrode detection limit, sensitivity, and pH effect on the performance of the fabricated sensor were evaluated by using different electrochemical methods including differential pulse voltammetry, cyclic voltammetry, and electrochemical impedance spectroscopy. The -OH, -SO3, and -COOgroups present in Ox/CMCS verified it could act as an brilliant substrate for polymerization and adsorption of aniline. Under optimal conditions of Ox/CMCS concentration in the fabricated S-Pani/Ox/CMCS bio-composite, the signal and the logarithm of 2-NP concentration showed a linear correlation, and a very low detection limit of 0.05 mu M was observed. The S-Pani/Ox/CMCS modified GCE confirmed high reproducibility, good stability, and durability was found applicable to the detection of 2-NP in milk, water, and orange juice samples. The obtained result for the fabricated sensor revealed that it was highly selective for the detection of 2-NP, which might play a significant role in human health protection and environmental monitoring applications.
引用
收藏
页数:17
相关论文
共 99 条
[41]   Polymer/carbon nanotubes coated graphite surfaces for highly sensitive nitrite detection [J].
Kuralay, Filiz ;
Dumangoz, Mehmet ;
Tunc, Selma .
TALANTA, 2015, 144 :1133-1138
[42]   A novel non-enzymatic glucose sensor based on NiFe(NPs)-polyaniline hybrid materials [J].
Lakhdari, Delloula ;
Guittoum, Abderrahim ;
Benbrahim, Nassima ;
Belgherbi, Ouafia ;
Berkani, Mohammed ;
Vasseghian, Yasser ;
Lakhdari, Nadjem .
FOOD AND CHEMICAL TOXICOLOGY, 2021, 151
[43]   Facile syntheses of bimetallic Prussian blue analogues (KxM[Fe(CN)6]•nH2O, M=Ni, Co, and Mn) for electrochemical determination of toxic 2-nitrophenol [J].
Li, Junhua ;
He, Lingzhi ;
Jiang, Jianbo ;
Xu, Zhifeng ;
Liu, Mengqin ;
Liu, Xing ;
Tong, Haixia ;
Liu, Zeng ;
Qian, Dong .
ELECTROCHIMICA ACTA, 2020, 353
[44]   Facile Preparation and Enhanced Capacitance of the Polyaniline/Sodium Alginate Nanofiber Network for Supercapacitors [J].
Li, Yingzhi ;
Zhao, Xin ;
Xu, Qian ;
Zhang, Qinghua ;
Chen, Dajun .
LANGMUIR, 2011, 27 (10) :6458-6463
[45]   Sulfonated Polyaniline Nanostructures Synthesized via Rapid Initiated Copolymerization with Controllable Morphology, Size, and Electrical Properties [J].
Liao, Yaozu ;
Strong, Veronica ;
Chian, Wei ;
Wang, Xia ;
Li, Xin-Gui ;
Kaner, Richard B. .
MACROMOLECULES, 2012, 45 (03) :1570-1579
[46]   Surface modification of cellulose scaffold with polypyrrole for the fabrication of flexible supercapacitor electrode with enhanced capacitance [J].
Liu, Shilin ;
He, Kuan ;
Wu, Xia ;
Luo, Xiaogang ;
Li, Bin .
RSC ADVANCES, 2015, 5 (106) :87266-87276
[47]   Electrochemical sensor for detection of p-nitrophenol based on nanoporous gold [J].
Liu, Zhaona ;
Du, Junguo ;
Qiu, Cuicui ;
Huang, Lihui ;
Ma, Houyi ;
Shen, Dazhong ;
Ding, Yi .
ELECTROCHEMISTRY COMMUNICATIONS, 2009, 11 (07) :1365-1368
[48]   Polyaniline as an electrocatalytic material [J].
Mandic, Z ;
Duic, L .
JOURNAL OF ELECTROANALYTICAL CHEMISTRY, 1996, 403 (1-2) :133-141
[49]  
Manikandan VS, 2018, ANALYST, V143, P4537, DOI [10.1039/C8AN00497H, 10.1039/c8an00497h]
[50]   Ellipsometric, electrogravimetric, and spectroelectrochemical studies of the redox process of sulfonated polyaniline [J].
Mello, RMQ ;
Torresi, RM ;
de Torresi, SIC ;
Ticianelli, EA .
LANGMUIR, 2000, 16 (20) :7835-7841