Development of 3D-printed myoelectric hand orthosis for patients with spinal cord injury

被引:65
|
作者
Yoo, Hyun-Joon [1 ]
Lee, Sangbaek [1 ]
Kim, Jongheon [2 ]
Park, Chanki [3 ]
Lee, Boreom [1 ]
机构
[1] Gwangju Inst Sci & Technol, Inst Integrated Technol, Dept Biomed Sci & Engn BMSE, 123 Cheomdan Gwagiro, Gwangju 61005, South Korea
[2] Inha Univ, Dept Mech Engn, 100 Inha Ro, Incheon 22212, South Korea
[3] Gwangju Inst Sci & Technol, Sch Mech Engn, 123 Cheomdan Gwagiro, Gwangju 61005, South Korea
基金
新加坡国家研究基金会;
关键词
Spinal cord injury; Assistive wearable robots; Orthosis; Three-dimensional printing; INDEPENDENCE MEASURE; WEARABLE-ROBOT; REHABILITATION; EXOSKELETON; RECOMMENDATIONS; DESIGN; SCIM;
D O I
10.1186/s12984-019-0633-6
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
Background Spinal cord injury (SCI) is a severe medical condition affecting the hand and locomotor function. New medical technologies, including various wearable devices, as well as rehabilitation treatments are being developed to enhance hand function in patients with SCI. As three-dimensional (3D) printing has the advantage of being able to produce low-cost personalized devices, there is a growing appeal to apply this technology to rehabilitation equipment in conjunction with scientific advances. In this study, we proposed a novel 3D-printed hand orthosis that is controlled by electromyography (EMG) signals. The orthosis was designed to aid the grasping function for patients with cervical SCI. We applied this hand exoskeleton system to individuals with tetraplegia due to SCI and validated its effectiveness. Methods The 3D architecture of the device was designed using computer-aided design software and printed with a polylactic acid filament. The dynamic hand orthosis enhanced the tenodesis grip to provide sufficient grasping function. The root mean square of the EMG signal was used as the input for controlling the device. Ten subjects with hand weakness due to chronic cervical SCI were enrolled in this study, and their hand function was assessed before and after wearing the orthosis. The Toronto Rehabilitation Institute Hand Function Test (TRI-HFT) was used as the primary outcome measure. Furthermore, improvements in functional independence in daily living and device usability were evaluated. Results The newly developed orthosis improved hand function of subjects, as determined using the TRI-HFT (p < 0.05). Furthermore, participants obtained immediate functionality on eating after wearing the orthosis. Moreover, most participants were satisfied with the device as determined by the usability test. There were no side effects associated with the experiment. Conclusions The 3D-printed myoelectric hand orthosis was intuitive, easy to use, and showed positive effects in its ability to handle objects encountered in daily life. This study proved that combining simple EMG-based control strategies and 3D printing techniques was feasible and promising in rehabilitation engineering.
引用
收藏
页数:14
相关论文
共 50 条
  • [41] Development of hybrid orthosis for standing, walking, and stair climbing after spinal cord injury
    Kobetic, Rudi
    To, Curtis S.
    Schnellenberger, John R.
    Audu, Musa L.
    Bulea, Thomas C.
    Gaudio, Richard
    Pinault, Gilles
    Tashman, Scott
    Triolo, Ronald J.
    JOURNAL OF REHABILITATION RESEARCH AND DEVELOPMENT, 2009, 46 (03): : 447 - 462
  • [42] Generation of 3D Printed Dorsal Spinal Neural Progenitor Cell Scaffolds for Spinal Cord Injury
    Huntemer-Silveira, A.
    Kim, H.
    McAlpine, M.
    Parr, A.
    CELL TRANSPLANTATION, 2024, 33
  • [43] Development and Effectiveness Testing of a Novel 3D-Printed Multi-Material Orthosis in Nurses with Plantar Foot Pain
    Chhikara, Komal
    Sidhu, Sarabjeet Singh
    Gupta, Shubham
    Saharawat, Sakshi
    Kataria, Chitra
    Chanda, Arnab
    PROSTHESIS, 2023, 5 (01): : 73 - 87
  • [44] Research and Development of a 3D-Printed Dynamic Finger Flexion Orthosis for Finger Extension Stiffness-A Preliminary Study
    Yu, June-Tzu
    Huang, Yi-Chao
    Chen, Chen-Sheng
    BIOENGINEERING-BASEL, 2024, 11 (04):
  • [45] Quantification of hand functional recovery in spinal cord injury patients
    Cohen, Erez James
    Righi, Gabriele
    Conti, Claudia
    De Santis, Claudia
    Sciarrone, Giorgia
    Del Popolo, Giulio
    JOURNAL OF SPINAL CORD MEDICINE, 2024, 47 (03): : 387 - 394
  • [46] Improving a 3D-Printed Artificial Anthropomorphic Hand using the Human Hand Model
    Sidher, Abhijaat
    Shen, Yantao
    2017 IEEE INTERNATIONAL CONFERENCE ON REAL-TIME COMPUTING AND ROBOTICS (RCAR), 2017, : 739 - 744
  • [47] Functional Assessment of 3D-Printed Multifunction Assistive Hand Device for Chronic Stroke Patients
    Chen, Zih-Hua
    Yang, Yun-Lin
    Lin, Kuang-Wei
    Sun, Pi-Chang
    Chen, Chen-Sheng
    IEEE TRANSACTIONS ON NEURAL SYSTEMS AND REHABILITATION ENGINEERING, 2022, 30 : 1261 - 1266
  • [48] A 3D-printed hand-powered centrifuge for molecular biology
    Byagathvalli, Gaurav
    Pomerantz, Aaron
    Sinha, Soham
    Standeven, Janet
    Bhamla, M. Saad
    PLOS BIOLOGY, 2019, 17 (05)
  • [49] Towards Behavior Design of a 3D-Printed Soft Robotic Hand
    Scharff, Rob B. N.
    Doubrovski, Eugeni L.
    Poelman, Wim A.
    Jonker, Pieter P.
    Wang, Charlie C. L.
    Geraedts, Jo M. P.
    SOFT ROBOTICS: TRENDS, APPLICATIONS AND CHALLENGES, 2017, 17 : 23 - 29
  • [50] Characteristics of a 3D-Printed Prosthetic Hand for Use in Developing Countries
    Dally, Corinne
    Johnson, Daniel
    Canon, Moriah
    Ritter, Sarah
    Mehta, Khanjan
    PROCEEDINGS OF THE FIFTH IEEE GLOBAL HUMANITARIAN TECHNOLOGY CONFERENCE GHTC 2015, 2015, : 66 - 70