Rapid, convenient, and highly sensitive detection of human hemoglobin in serum using a high-affinity bivalent antibody-enzyme complex

被引:17
作者
Miura, Daimei [1 ]
Kimura, Hayato [1 ]
Tsugawa, Wakako [1 ]
Ikebukuro, Kazunori [1 ]
Sode, Koji [2 ,3 ]
Asano, Ryutaro [1 ]
机构
[1] Tokyo Univ Agr & Technol, Grad Sch Engn, Dept Biotechnol & Life Sci, Tokyo 1848588, Japan
[2] Univ N Carolina, Joint Dept Biomed Engn, Chapel Hill, NC 27599 USA
[3] North Carolina State Univ, Chapel Hill, NC 27599 USA
基金
日本学术振兴会;
关键词
Bivalent antibody-enzyme complex; Catcher/tag system; Glucose dehydrogenase; Hemoglobin; Homogeneous electrochemical detection; Single-chain variable fragment; ELECTROCHEMICAL SENSORS; PROTEIN; CONSTRUCTION; IMMUNOASSAY; EXPRESSION; DIABODY; TOOL;
D O I
10.1016/j.talanta.2021.122638
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
Human hemoglobin (Hb) is a biomarker of several diseases, and monitoring of Hb levels is required during emergent surgery. However, rapid and sensitive Hb detection methods are yet to be developed. The present study established a rapid, convenient, and highly sensitive detection method for Hb in human serum using a bivalent antibody-enzyme complex (AEC). AECs are promising sensing elements because of their ability to bind specific targets and their catalytic activity that produce signals. We recently reported a convenient and universal method to fabricate bivalent AECs with two antibody fragments, using the SpyCatcher/SpyTag system. The present study applied a bivalent AEC for highly sensitive and quantitative detection of human Hb. The bivalent anti-Hb AEC was successfully prepared by incubating both N- and C-terminus SpyCatcher-fused glucose dehydrogenase and SpyTag-fused anti-Hb single-chain variable fragments at 4 degrees C. As expected, the bivalent AEC for Hb with a multimeric structure showed higher affinity than the monovalent AEC, by means of avidity effects, unlike that for soluble epidermal growth factor receptor with a monomeric structure; this contributed to a great improvement in sensitivity. Finally, we established a rapid and wash-free homogeneous electrochemical detection system for Hb by integrating magnetic beads. The linear range of the system completely covered the clinically required Hb levels, even in human serum. This technology provides an ideal point-of-care test for Hb and other multimeric biomarkers.
引用
收藏
页数:8
相关论文
共 43 条
[1]   Domain order of a bispecific diabody dramatically enhances its antitumor activity beyond structural format conversion: the case of the hEx3 diabody [J].
Asano, Ryutaro ;
Kumagai, Takashi ;
Nagai, Keisuke ;
Taki, Shintaro ;
Shimomura, Ippei ;
Arai, Kyoko ;
Ogata, Hiromi ;
Okada, Mai ;
Hayasaka, Fumitaka ;
Sanada, Hideaki ;
Nakanishi, Takeshi ;
Karvonen, Teemu ;
Hayashi, Hiroki ;
Katayose, Yu ;
Unno, Michiaki ;
Kudo, Toshio ;
Umetsu, Mitsuo ;
Kumagai, Izumi .
PROTEIN ENGINEERING DESIGN & SELECTION, 2013, 26 (05) :359-367
[2]   Continuous and noninvasive hemoglobin monitoring reduces red blood cell transfusion during neurosurgery: a prospective cohort study [J].
Awada, Wael N. ;
Mohmoued, Maher F. ;
Radwan, Tarek M. ;
Hussien, Gomaa Z. ;
Elkady, Hany W. .
JOURNAL OF CLINICAL MONITORING AND COMPUTING, 2015, 29 (06) :733-740
[3]   Nanoteamwork: covalent protein assembly beyond duets towards protein ensembles and orchestras [J].
Banerjee, Anusuya ;
Howarth, Mark .
CURRENT OPINION IN BIOTECHNOLOGY, 2018, 51 :16-23
[4]   Hemoglobin detection using carbon dots as a fluorescence probe [J].
Barati, Ali ;
Shamsipur, Mojtaba ;
Abdollahi, Hamid .
BIOSENSORS & BIOELECTRONICS, 2015, 71 :470-475
[5]   Adaptation of red blood cell lysis represents a fundamental breakthrough that improves the sensitivity of Salmonella detection in blood [J].
Boyd, M. A. ;
Tennant, S. M. ;
Melendez, J. H. ;
Toema, D. ;
Galen, J. E. ;
Geddes, C. D. ;
Levine, M. M. .
JOURNAL OF APPLIED MICROBIOLOGY, 2015, 118 (05) :1199-1209
[6]   Butelase-mediated synthesis of protein thioesters and its application for tandem chemoenzymatic ligation [J].
Cao, Yuan ;
Nguyen, Giang K. T. ;
Tam, James P. ;
Liu, Chuan-Fa .
CHEMICAL COMMUNICATIONS, 2015, 51 (97) :17289-17292
[7]   Using photoluminescent gold nanodots to detect hemoglobin in diluted blood samples [J].
Chen, Li-Yi ;
Huang, Chih-Ching ;
Chen, Wei-Yu ;
Lin, Han-Jia ;
Chang, Huan-Tsung .
BIOSENSORS & BIOELECTRONICS, 2013, 43 :38-44
[8]   Crystal structure of a 3B3 variant-A broadly neutralizing HIV-1 scFv antibody [J].
Clark, K. Reed ;
Walsh, Scott T. R. .
PROTEIN SCIENCE, 2009, 18 (12) :2429-2441
[9]   Protein cross-linking tools for the construction of nanomaterials [J].
Domeradzka, Natalia E. ;
Werten, Marc W. T. ;
de Wolf, Frits A. ;
de Vries, Renko .
CURRENT OPINION IN BIOTECHNOLOGY, 2016, 39 :61-67
[10]   Stability improvement of antibodies for extracellular and intracellular applications:: CDR grafting to stable frameworks and structure-based framework engineering [J].
Ewert, S ;
Honegger, A ;
Plückthun, A .
METHODS, 2004, 34 (02) :184-199