A novel method for ranitidine hydrochloride determination in aqueous solution based on fluorescence quenching of functionalised CdS QDs through photoinduced charge transfer process: Spectroscopic approach

被引:32
作者
Gore, Anil Hanumant [1 ]
Mote, Umesh Shivaji [1 ]
Tele, Shahaji Sopan [1 ]
Anbhule, Prashant Vikramrao [1 ]
Rath, Madhab Chandra [2 ]
Patil, Shivajirao Raghunath [1 ]
Kolekar, Govind Bhagwan [1 ]
机构
[1] Shivaji Univ, Dept Chem, Fluorescence Spect Res Lab, Kolhapur 416004, Maharashtra, India
[2] Bhabha Atom Res Ctr, Radiat & Photochem Div, Bombay 400085, Maharashtra, India
关键词
CADMIUM-SULFIDE NANOPARTICLES; FLOW-INJECTION ANALYSIS; CDTE QUANTUM DOTS; SPECTROPHOTOMETRIC DETERMINATION; PHARMACEUTICAL FORMULATIONS; LUMINESCENT PROBES; NANOCRYSTALS; NIZATIDINE; URINE; FORMS;
D O I
10.1039/c0an01038c
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
A novel method for the quantitative determination of ranitidine hydrochloride (RNH) based on the fluorescence quenching of functionalised CdS quantum dots (QDs) by RNH in aqueous solution was proposed. The method is simple, rapid, specific and highly sensitive with good precision. The thioglycolic acid (TGA)-capped CdS QDs were synthesized from cadmium nitrate and sodium sulfide in alkaline solution. Under the optimal conditions, the Stern-Volmer calibration plot of F-0/F against concentration of RNH was linear in the range of 0.50-15.0 mu g mL(-1) with a correlation coefficient of 0.996. The limit of detection (LOD) was 0.38 mu g mL(-1). The method was satisfactorily applied to the direct determination of RNH in pharmaceutical formulations with no significant interference from excipients. The results were found to be in good agreement with those obtained by the reference method and the claimed value. The accuracy and reliability of the method were further ascertained by recovery studies via the standard-addition method, with percentage recoveries in the range of 98.47 to 102.30%. The possible fluorescence quenching mechanism for the reaction was also discussed.
引用
收藏
页码:2606 / 2612
页数:7
相关论文
共 54 条
[1]   Determination of polymorphic forms of ranitidine-HCl by DRIFTS and XRPD [J].
Agatonovic-Kustrin, S ;
Rades, T ;
Wu, V ;
Saville, D ;
Tucker, IG .
JOURNAL OF PHARMACEUTICAL AND BIOMEDICAL ANALYSIS, 2001, 25 (5-6) :741-750
[2]   DETERMINATION OF RANITIDINE IN A BIOLOGICAL-MATERIAL BY USING DIFFERENTIAL PULSE ADSORPTIVE STRIPPING VOLTAMMETRY [J].
ALTINOZ, S ;
OZER, D ;
TEMIZER, A ;
BAYRAKTAR, Y .
ANALYTICAL LETTERS, 1992, 25 (01) :111-118
[3]   Simple and universal HPLC-UV method to determine cimetidine, ranitidine, famotidine and nizatidine in urine: Application to the analysis of ranitidine and its metabolites in human volunteers [J].
Ashiru, Diane A. I. ;
Patel, Rajesh ;
Basit, Abdul W. .
JOURNAL OF CHROMATOGRAPHY B-ANALYTICAL TECHNOLOGIES IN THE BIOMEDICAL AND LIFE SCIENCES, 2007, 860 (02) :235-240
[4]   Determination of ranitidine and salbutamol by flow injection analysis with chemiluminescence detection [J].
Barnett, NW ;
Hindson, BJ ;
Lewis, SW .
ANALYTICA CHIMICA ACTA, 1999, 384 (02) :151-158
[5]  
Basavaiah K, 2004, Farmaco, V59, P147
[6]   A new determining method of copper(III) ions at ng ml-1 levels based on quenching of the water-soluble nanocrystals fluorescence [J].
Bo, C ;
Ping, Z .
ANALYTICAL AND BIOANALYTICAL CHEMISTRY, 2005, 381 (04) :986-992
[7]  
BODNARCHUK MI, 2004, THEOR EXP CHEM, V40, P287, DOI DOI 10.1023/B:THEC.0000049074.31907.81
[8]   Synthesis of novel nanocrystals as fluorescent sensors for Hg2+ ions [J].
Chen, B ;
Ying, Y ;
Zhou, ZT ;
Zhong, P .
CHEMISTRY LETTERS, 2004, 33 (12) :1608-1609
[9]   Functionalized semiconductor nanocrystals for ultrasensitive detection of peptides [J].
Chen, XD ;
Wang, XB ;
Liu, L ;
Yang, DC ;
Fan, L .
ANALYTICA CHIMICA ACTA, 2005, 542 (02) :144-150
[10]   Spectrophotometric determination of H2-receptor antagonists via their oxidation with cerium(IV) [J].
Darwish, Ibrahim A. ;
Hussein, Samiha A. ;
Mahmoud, Ashraf M. ;
Hassan, Ahmed I. .
SPECTROCHIMICA ACTA PART A-MOLECULAR AND BIOMOLECULAR SPECTROSCOPY, 2008, 69 (01) :33-40