Conical slit and conventional X-ray sources: Challenging steps for calcium spots detection

被引:0
|
作者
Fioreze, M. [1 ]
Cusatis, C. [1 ]
Keister, J. W. [1 ]
Honnicke, M. G. [1 ]
机构
[1] Univ Fed, Foz Iguacu, PR, Brazil
关键词
Conical slit; Microcalcifications; Diffraction detection; SYNCHROTRON-RADIATION; DIFFRACTION; BREAST; MICROCALCIFICATIONS; MAMMOGRAPHY; CRYSTALLINITY; TRANSMISSION; SCATTERING; BENIGN;
D O I
10.1016/j.nima.2017.06.026
中图分类号
TH7 [仪器、仪表];
学科分类号
0804 ; 080401 ; 081102 ;
摘要
An easy and simple to build conical slit (CS) was designed and tested, in a sample model approach, in order to check its possible use to detect Calcium Oxalate (CO) breast microcalcifications (MC) using conventional X-ray sources. A single-cone conical slit (SCCS) and a multi-cones conical slit (MCCS) were designed and constructed. Also, the CS apertures were calculated in order to maximize the diffracted intensity, while also providing sufficient angular resolution. The detection was done by scintillation detector and by films. The alignment of SCCS and MCCS is straightforward. The SCCS and MCCS capability in resolving CO diffraction cones were tested under different background scattering condition. For this, composite samples made up of CO embedded in different soft materials (paraffin wax or polypropylene or polyamide) have been explored. SCCS showed some limitation especially due to the superposition with low order CO powder diffraction cones and diffraction cones arising from paraffin wax and polypropylene. On the other hand MCCS showed to be efficient to resolve the CO diffraction cones in any case. MCCS shall be useful for next step tests with real in-vitro breast samples. (C) 2017 Elsevier B.V. All rights reserved.
引用
收藏
页码:171 / 181
页数:11
相关论文
共 50 条
  • [21] Review of challenges in medical diagnostic x-ray sources
    Price, JS
    ADVANCES IN LABORATORY-BASED X-RAY SOURCES AND OPTICS II, 2001, 4502 : 1 - 9
  • [22] Future diffusion studies with new X-ray sources
    G. Vogl
    Hyperfine Interactions, 2012, 204 : 65 - 70
  • [23] High efficiency of soft X-ray radiation reprocessing in supersoft X-ray sources due to multiple scattering
    Suleimanov, V
    Meyer, F
    Meyer-Hofmeister, E
    ASTRONOMY & ASTROPHYSICS, 2003, 401 (03): : 1009 - 1015
  • [24] On the maximum accretion luminosity of magnetized neutron stars: connecting X-ray pulsars and ultraluminous X-ray sources
    Mushtukov, Alexander A.
    Suleimanov, Valery F.
    Tsygankov, Sergey S.
    Poutanen, Juri
    MONTHLY NOTICES OF THE ROYAL ASTRONOMICAL SOCIETY, 2015, 454 (03) : 2539 - 2548
  • [25] High intensity compact Compton X-ray sources: Challenges and potential of applications
    Jacquet, M.
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION B-BEAM INTERACTIONS WITH MATERIALS AND ATOMS, 2014, 331 : 1 - 5
  • [26] Accelerator-based X-ray sources: synchrotron radiation, X-ray free electron lasers and beyond
    Ishikawa, Tetsuya
    PHILOSOPHICAL TRANSACTIONS OF THE ROYAL SOCIETY A-MATHEMATICAL PHYSICAL AND ENGINEERING SCIENCES, 2019, 377 (2147):
  • [27] X-ray crystallography in Italy: from the early steps to the present days
    Viterbo, Davide
    RENDICONTI LINCEI-SCIENZE FISICHE E NATURALI, 2013, 24 : S19 - S32
  • [28] Simulation tools for analyzer-based X-ray phase contrast imaging system with a conventional X-ray source
    Caudevilla, Oriol
    Zhou, Wei
    Stoupin, Stanislav
    Verman, Boris
    Brankov, J. G.
    ADVANCES IN LABORATORY-BASED X-RAY SOURCES, OPTICS, AND APPLICATIONS V, 2016, 9964
  • [29] X-ray CTR scattering measurements using conventional X-ray source to study semiconductor hetero-interfaces
    Maeda, Y.
    Mizuno, T.
    Mori, A.
    Tabuchi, M.
    Takeda, Y.
    TRANSACTIONS OF THE MATERIALS RESEARCH SOCIETY OF JAPAN, VOL 33, NO 3, 2008, 33 (03): : 591 - 594
  • [30] Enhanced contrast in X-ray microtomographic images of the membranous labyrinth using different X-ray sources and scanning modes
    Goyens, Jana
    Vasilopoulou-Kampitsi, Menelia
    Claes, Raf
    Sijbers, Jan
    Mancini, Lucia
    JOURNAL OF ANATOMY, 2018, 233 (06) : 770 - 782