In vivo life sign application of dielectric spectroscopy and non-invasive glucose monitoring

被引:33
作者
Talary, Mark S. [1 ]
Dewarrat, Francois [1 ]
Huber, Daniel [1 ]
Caduff, Andreas [1 ]
机构
[1] Solianis Monitoring AG, CH-8050 Zurich, Switzerland
关键词
Biosensors; sensors; conductivity; dielectric properties; relaxation; electric modulus; optical spectroscopy; hydration; water;
D O I
10.1016/j.jnoncrysol.2007.03.038
中图分类号
TQ174 [陶瓷工业]; TB3 [工程材料学];
学科分类号
0805 ; 080502 ;
摘要
Previous developments of dielectric spectroscopy based non-invasive continuous monitoring devices have indicated that the measured impedances of the skin and underlying tissue can be influenced by a number of perturbing parameters such as changes in humidity, sweating and blood perfusion. Therefore successful glucose monitoring requires a range of sensors to be developed and combined in a multisensor concept to measure changes in such perturbing parameters. This work evaluates the feasibility of using the developed components of such a multisensor system to make corrections to the impedance measurements. (c) 2007 Elsevier B.V. All rights reserved.
引用
收藏
页码:4515 / 4517
页数:3
相关论文
共 8 条
  • [1] First human experiments with a novel non-invasive, non-optical continuous glucose monitoring system
    Caduff, A
    Hirt, E
    Feldman, Y
    Ali, Z
    Heinemann, L
    [J]. BIOSENSORS & BIOELECTRONICS, 2003, 19 (03) : 209 - 217
  • [2] Caduff A, 2006, BIOSENS BIOELECTRON
  • [3] Impact of environmental temperature on skin thickness and microvascular blood flow in subjects with and without diabetes
    Forst, T.
    Caduff, A.
    Talary, M.
    Weder, M.
    Braendle, M.
    Kann, P.
    Flacke, F.
    Friedrich, Ch.
    Pfuetzner, A.
    [J]. DIABETES TECHNOLOGY & THERAPEUTICS, 2006, 8 (01) : 94 - 101
  • [4] GLUCOSE CLAMPS WITH THE BIOSTATOR - A CRITICAL REAPPRAISAL
    HEINEMANN, L
    AMPUDIABLASCO, FJ
    [J]. HORMONE AND METABOLIC RESEARCH, 1994, 26 (12) : 579 - 583
  • [5] Hyponatremia: Evaluating the correction factor for hyperglycemia
    Hillier, TA
    Abbott, RD
    Barrett, EJ
    [J]. AMERICAN JOURNAL OF MEDICINE, 1999, 106 (04) : 399 - 403
  • [6] Khalil Omar S, 2004, Diabetes Technol Ther, V6, P660, DOI 10.1089/dia.2004.6.660
  • [7] Pfutzner Andreas, 2004, Diabetes Technol Ther, V6, P435, DOI 10.1089/1520915041705839
  • [8] An RCL sensor for measuring dielectrically lossy materials in the MHz frequency range - 1. Comparison of hydrogel model simulation with actual hydrogel impedance measurements
    Talary, MS
    Dewarrat, F
    Caduff, A
    Puzenko, A
    Ryabov, Y
    Feldman, Y
    [J]. IEEE TRANSACTIONS ON DIELECTRICS AND ELECTRICAL INSULATION, 2006, 13 (02) : 247 - 256