Design and Experimental Assessment of Low-Noise Piezoelectric Microelectromechanical Systems Vibration Sensors

被引:0
|
作者
Hake, Alison E. [1 ]
Zhao, Chuming [1 ,2 ]
Sung, Wang-Kyung [3 ,4 ]
Grosh, Karl [1 ,5 ]
机构
[1] Univ Michigan, Dept Mech Engn, Ann Arbor, MI 48109 USA
[2] Facebook Real Labs, Redmond, WA 98052 USA
[3] Vesper Technol Inc, Boston, MA 02110 USA
[4] TDK Invensense, San Jose, CA 95110 USA
[5] Univ Michigan, Dept Biomed Engn, Ann Arbor, MI 48109 USA
关键词
Accelerometer; microelectromechanical systems (MEMS); implantable sensors; auditory prostheses; ACCELEROMETER;
D O I
10.1109/JSEN.2021.3085825
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
The ubiquity of vibration sensors and accelerometers, as well as advances in microfabrication technologies, have led to the development of implantable devices for biomedical applications. This work describes a piezoelectric microelectromechanical systems accelerometer designed for potential use in auditory prostheses. The design includes an aluminum nitride bimorph beam with a silicon proof mass. Analytic models of the device sensitivity and noise are presented. These lead to a minimum detectable acceleration cost function for the sensor that can be used to optimize sensor designs more effectively than typical sensitivity maximizing or electrical noise minimizing approaches. A fabricated device with a 1 mu m thick, 100 mu m long, and 700 mu m wide beam and a 400 mu m thick, 63 mu m long, and 740 mu m wide proof mass is tested experimentally. Results indicate accurate modeling of the system sensitivity up to the first resonant frequency (1420 Hz). The low-frequency sensitivity of the device is 1.3 mV/g, and the input referred noise is 36.3 nV/root Hz at 100 Hz and 11.8 nV/root Hz at 1 kHz. The resulting minimum detectable acceleration at 100 Hz and 1 kHz is 28 mu g/root Hz and 9.1 mu g/root Hz, respectively. A brief explanation of the use of the validated cost function for sensor design is provided, as well as an example comparing the piezoelectric sensor design to another from the literature. It is concluded that a traditional single-resonance design cannot compete with the performance of acoustic sensors; therefore, novel device designs must be considered for implantable auditory prosthesis applications.
引用
收藏
页码:17703 / 17711
页数:9
相关论文
共 50 条
  • [31] The design of a low-noise preamplifier for MRI
    Cao XueMing
    Zu DongLin
    Zhao XuNa
    Fan Yang
    Gao JiaHong
    SCIENCE CHINA-TECHNOLOGICAL SCIENCES, 2011, 54 (07) : 1766 - 1770
  • [32] Design of low-noise avalanche photodiodes
    David, JPR
    Tan, CH
    Plimmer, SA
    Rees, GJ
    Tozer, RC
    Robson, PN
    OPTOELECTRONIC INTEGRATED CIRCUITS IV, 2000, 3950 : 30 - 38
  • [33] Design strategies for multi-channel low-noise recording systems
    Rieger, Robert
    Pan, Yen-Yow
    Taylor, John
    2007 IEEE INTERNATIONAL SYMPOSIUM ON CIRCUITS AND SYSTEMS, VOLS 1-11, 2007, : 561 - +
  • [34] Tricks of the trade for low-noise design
    Brewer, RW
    MACHINE DESIGN, 1997, 69 (19) : 99 - &
  • [35] THE DESIGN OF A LOW-NOISE AMPLIFIER STAGE
    SUNDUCHKOV, KS
    GALITSYN, VV
    TUZENKO, AP
    TELECOMMUNICATIONS AND RADIO ENGINEERING, 1992, 47 (07) : 140 - 144
  • [36] Low-noise design of cylinder heads
    Ropke, Peter
    Schwaderlapp, Markus
    Kley, Philipp
    MTZ Motortechnische Zeitschrift, 1994, 55 (06) : 366 - 373
  • [37] Design of an integrated low-noise read-out system for DNA capacitive sensors
    De Venuto, Daniela
    Indiveri, Giancarlo
    Valentini, Antonio
    2007 2ND INTERNATIONAL WORKSHOP ON ADVANCES IN SENSORS AND INTERFACE, 2007, : 62 - +
  • [38] Design strategies for multi-channel low-noise recording systems
    Rieger, Robert
    Taylor, John T.
    ANALOG INTEGRATED CIRCUITS AND SIGNAL PROCESSING, 2009, 58 (02) : 123 - 133
  • [39] Permanent magnet synchronous machine design for low-noise drive systems
    Pop-Piglesan, F.
    Jurca, F.
    Oprea, C.
    Martis, C.
    PROCEEDINGS OF INTERNATIONAL CONFERENCE ON NOISE AND VIBRATION ENGINEERING (ISMA2014) AND INTERNATIONAL CONFERENCE ON UNCERTAINTY IN STRUCTURAL DYNAMICS (USD2014), 2014, : 1387 - 1399
  • [40] Design strategies for multi-channel low-noise recording systems
    Robert Rieger
    John T. Taylor
    Analog Integrated Circuits and Signal Processing, 2009, 58 : 123 - 133