Chronic recording and electrochemical performance of Utah microelectrode arrays implanted in rat motor cortex

被引:44
作者
Black, Bryan J. [1 ]
Kanneganti, Aswini [1 ]
Joshi-Imre, Alexandra [1 ]
Rihani, Rashed [1 ]
Chakraborty, Bitan [1 ]
Abbott, Justin [1 ]
Pancrazio, Joseph J. [1 ]
Cogan, Stuart F. [1 ]
机构
[1] Univ Texas Dallas, Dept Bioengn, 800 W Campbell Rd,Bioengn & Sci Bldg 13-601, Richardson, TX 75080 USA
关键词
chronic recording; electrical stimulation; rodent models; Utah electrode array; INTRACORTICAL MICROSTIMULATION; BRAIN-TISSUE; STIMULATION; RECOVERY; STROKE; ADULT; NEUROSTIMULATION; PLASTICITY; IMPEDANCE; BLIND;
D O I
10.1152/jn.00181.2018
中图分类号
Q189 [神经科学];
学科分类号
071006 ;
摘要
Multisite implantable electrode arrays serve as a tool to understand cortical network connectivity and plasticity. Furthermore, they enable electrical stimulation to drive plasticity, study motor/sensory mapping, or provide network input for controlling brain-computer interfaces. Neurobehavioral rodent models are prevalent in studies of motor cortex injury and recovery as well as restoration of auditory/visual cues due to their relatively low cost and ease of training. Therefore, it is important to understand the chronic performance of relevant electrode arrays in rodent models. In this report, we evaluate the chronic recording and electrochemical performance of 16-channel Utah electrode arrays. the current state-of-the-art in pre-/clinical cortical recording and stimulation, in rat motor cortex over a period of 6 mo. The single-unit active electrode yield decreased from 52.8 +/- 10.0 (week 1) to 13.4 +/- 5.1% (week 24). Similarly, the total number of single units recorded on all electrodes across all arrays decreased from 106 to 15 over the same time period. Parallel measurements of electrochemical impedance spectra and cathodic charge storage capacity exhibited significant changes in electrochemical characteristics consistent with development of electrolyte leakage pathways over time. Additionally, measurements of maximum cathodal potential excursion indicated that only a relatively small fraction of electrodes (10-35% at 1 and 24 wk postimplantation) were capable of delivering relevant currents (20 mu A at 4 nC/ph) without exceeding negative or positive electrochemical potential limits. In total, our findings suggest mainly abiotic failure modes, including mechanical wire breakage as well as degradation of conducting and insulating substrates. NEW & NOTEWORTHY Multisite implantable electrode arrays serve as a tool to record cortical network activity and enable electrical stimulation to drive plasticity or provide network feedback. The use of rodent models in these fields is prevalent. We evaluated chronic recording and electrochemical performance of 16-channel Utah electrode arrays in rat motor cortex over a period of 6 mo. We primarily observed abiotic failure modes suggestive of mechanical wire breakage and/or degradation of insulation.
引用
收藏
页码:2083 / 2090
页数:8
相关论文
共 40 条
[21]   Chronic response of adult rat brain tissue to implants anchored to the skull [J].
Kim, YT ;
Hitchcock, RW ;
Bridge, MJ ;
Tresco, PA .
BIOMATERIALS, 2004, 25 (12) :2229-2237
[22]  
Lowery AJ, 2015, IEEE ENG MED BIO, P1041, DOI 10.1109/EMBC.2015.7318543
[23]   Recovery and brain reorganization after stroke in adult and aged rats [J].
Markus, TM ;
Tsai, SY ;
Bollnow, MR ;
Farrer, RG ;
O'Brien, TE ;
Kindler-Baumann, DR ;
Rausch, M ;
Rudin, M ;
Wiessner, C ;
Mir, AK ;
Schwab, ME ;
Kartje, GL .
ANNALS OF NEUROLOGY, 2005, 58 (06) :950-953
[24]   In Vivo Electrical Impedance Spectroscopy of Tissue Reaction to Microelectrode Arraysl [J].
Mercanzini, Andre ;
Colin, Philippe ;
Bensadoun, Jean-Charles ;
Bertsch, Arnaud ;
Renaud, Philippe .
IEEE TRANSACTIONS ON BIOMEDICAL ENGINEERING, 2009, 56 (07) :1909-1918
[25]   In vitro and In vivo Electrochemical Characterization of a Microfabricated Neural Probe [J].
Musa, S. ;
Welkenhuysen, M. ;
Prodanov, D. ;
Eberle, W. ;
Bartic, C. ;
Nuttin, B. ;
Borghs, G. .
2009 ANNUAL INTERNATIONAL CONFERENCE OF THE IEEE ENGINEERING IN MEDICINE AND BIOLOGY SOCIETY, VOLS 1-20, 2009, :7143-7146
[26]  
Nolta NF, 2016, THESIS
[27]   BBB leakage, astrogliosis, and tissue loss correlate with silicon microelectrode array recording performance [J].
Nolta, Nicholas F. ;
Christensen, Michael B. ;
Crane, Paul D. ;
Skousen, John L. ;
Tresco, Patrick A. .
BIOMATERIALS, 2015, 53 :753-762
[28]   Response of brain tissue to chronically implanted neural electrodes [J].
Polikov, VS ;
Tresco, PA ;
Reichert, WM .
JOURNAL OF NEUROSCIENCE METHODS, 2005, 148 (01) :1-18
[29]   Comprehensive characterization and failure modes of tungsten microwire arrays in chronic neural implants [J].
Prasad, Abhishek ;
Xue, Qing-Shan ;
Sankar, Viswanath ;
Nishida, Toshikazu ;
Shaw, Gerry ;
Streit, Wolfgang J. ;
Sanchez, Justin C. .
JOURNAL OF NEURAL ENGINEERING, 2012, 9 (05)
[30]   Stem Cell Mediation of Functional Recovery after Stroke in the Rat [J].
Ramos-Cabrer, Pedro ;
Justicia, Carles ;
Wiedermann, Dirk ;
Hoehn, Mathias .
PLOS ONE, 2010, 5 (09) :1-11