Does robotic assisted technology improve the accuracy of acetabular component positioning in patients with DDH?

被引:16
作者
Zhou, Yixin [1 ]
Shao, Hongyi [1 ]
Huang, Yong [1 ]
Deng, Wang [1 ]
Yang, Dejin [1 ]
Bian, Tao [1 ]
机构
[1] Peking Univ, Beijing Jishuitan Hosp, Dept Orthopaed Surg, Clin Coll 4, Beijing 100035, Peoples R China
关键词
arthroplasty; dysplasia; hip; robotic assisted technology; TOTAL HIP-ARTHROPLASTY; DEVELOPMENTAL DYSPLASIA; PLACEMENT; RISK;
D O I
10.1177/23094990211025325
中图分类号
R826.8 [整形外科学]; R782.2 [口腔颌面部整形外科学]; R726.2 [小儿整形外科学]; R62 [整形外科学(修复外科学)];
学科分类号
摘要
Background: Accurate positioning of the acetabular component is key in performing total hip arthroplasty (THA). However, reconstruction of the acetabulum in the setting of developmental dysplasia of the hip (DDH) is a challenge. Robotic assisted THA has the potential to improve the accuracy of implantation of the acetabular cup in cases with DDH. The purpose of this study was to assess whether robotic technology improves the accuracy of acetabular component positioning in patients with DDH. Material and methods: We included 59 THAs using robotic assisted technology from June 2019 to January 2020 as the study group. These were compared to conventional THAs without robotic technology after control for age, gender, body mass index (BMI), Crowe type and operation date. Radiographic measurements were taken by 2 blinded orthopaedic residents. The percentage of hips within the Lewinnek and Collanan safe zones were calculated, along with acetabular rotation centers for the "target zone." Surgical time and perioperative bleeding were also compared between both groups. Results: One patient suffered dislocation in conventional group while no dislocation occurred in robotic group. The acetabular components of the robotic assisted group had more cases located within the Lewinnek (p = 0.013) and Collanan (p = 0.008) safe zones than conventional group (94.9% vs 79.7% and 74.6% vs 50.8%). There were 7 cases in conventional group and 4 cases in robotic group that had more lateral or more superior rotational centers of THA, but did not reach statistical significance (p = 0.342). No statistical difference was detected between groups with regards to blood loss (p = 0.098) and surgical time (p = 0.602). Conclusion: Robot assisted technology can assist surgeons with implanting acetabular cups more in Lewinnek and Callanan safe zone than conventional techniques without additional blood loss and surgical time.
引用
收藏
页数:7
相关论文
共 31 条
[1]  
Biedermann R, 2005, J BONE JOINT SURG BR, V87B, P762, DOI 10.1302/0301-620X.87B6
[2]   Robotics in Hip and Knee Arthroplasty: Real Innovation or Marketing Ruse [J].
Booth, Robert E. ;
Sharkey, Peter F. ;
Parvizi, Javad .
JOURNAL OF ARTHROPLASTY, 2019, 34 (10) :2197-2198
[3]   Poor accuracy of freehand cup positioning during total hip arthroplasty [J].
Bosker, B. H. ;
Verheyen, C. C. P. M. ;
Horstmann, W. G. ;
Tulp, N. J. A. .
ARCHIVES OF ORTHOPAEDIC AND TRAUMA SURGERY, 2007, 127 (05) :375-379
[4]   The John Charnley Award Risk Factors for Cup Malpositioning Quality Improvement Through a Joint Registry at a Tertiary Hospital [J].
Callanan, Mark C. ;
Jarrett, Bryan ;
Bragdon, Charles R. ;
Zurakowski, David ;
Rubash, Harry E. ;
Freiberg, Andrew A. ;
Malchau, Henrik .
CLINICAL ORTHOPAEDICS AND RELATED RESEARCH, 2011, 469 (02) :319-329
[5]   Robotic Technology in Orthopaedic Surgery [J].
Chen, Antonia F. ;
Kazarian, Gregory S. ;
Jessop, Galen W. ;
Makhdom, Asim .
JOURNAL OF BONE AND JOINT SURGERY-AMERICAN VOLUME, 2018, 100 (22) :1984-1992
[6]   Robotic-assisted compared with conventional total hip arthroplasty: systematic review and meta-analysis [J].
Chen, Xi ;
Xiong, Jianping ;
Wang, Peipei ;
Zhu, Shibai ;
Qi, Wenting ;
Peng, Huiming ;
Yu, Lingjia ;
Qian, Wenwei .
POSTGRADUATE MEDICAL JOURNAL, 2018, 94 (1112) :335-341
[7]   Accuracy of Component Positioning in 1980 Total Hip Arthroplasties: A Comparative Analysis by Surgical Technique and Mode of Guidance [J].
Domb, Benjamin G. ;
Redmond, John M. ;
Louis, Steven S. ;
Alden, Kris J. ;
Daley, Robert J. ;
LaReau, Justin M. ;
Petrakos, Alexandra E. ;
Gui, Chengcheng ;
Suarez-Ahedo, Carlos .
JOURNAL OF ARTHROPLASTY, 2015, 30 (12) :2208-2218
[8]   Comparison of Robotic-assisted and Conventional Acetabular Cup Placement in THA: A Matched-pair Controlled Study [J].
Domb, Benjamin G. ;
El Bitar, Youssef F. ;
Sadik, Adam Y. ;
Stake, Christine E. ;
Botser, Itamar B. .
CLINICAL ORTHOPAEDICS AND RELATED RESEARCH, 2014, 472 (01) :329-336
[9]  
El Bitar Youssef F, 2015, Am J Orthop (Belle Mead NJ), V44, P265
[10]   Tranexamic acid decreases external blood loss but not hidden blood loss in total knee replacement [J].
Good, L ;
Peterson, E ;
Lisander, B .
BRITISH JOURNAL OF ANAESTHESIA, 2003, 90 (05) :596-599