Reactive Current Reshaping With Series Resonance Damping for Three-Phase Buck-Type Dynamic Capacitor

被引:4
|
作者
Wu, Qi [1 ]
Dai, Ke [1 ]
Chen, Xinwen [2 ]
Zhang, Yuxiao [1 ]
Xu, Chen [1 ]
Dai, Ziwei [3 ]
机构
[1] Huazhong Univ Sci & Technol, Sch Elect & Elect Engn, State Key Lab Adv Electromagnet Engn & Technol, Wuhan 430074, Hubei, Peoples R China
[2] Huazhong Inst Electroopt, Wuhan Natl Lab Optoelect, Wuhan 430223, Hubei, Peoples R China
[3] Rensselaer Polytech Inst, Dept Elect Comp & Syst Engn, Troy, NY 12180 USA
来源
IEEE ACCESS | 2019年 / 7卷
基金
中国国家自然科学基金;
关键词
Harmonic analysis; Reactive power; Damping; Power capacitors; Harmonic distortion; Voltage control; Buck-type dynamic capacitor; reactive power compensation; waveform distortion; current reshaping; series resonance damping; DEAD-TIME; HARMONIC SUPPRESSION; COMPENSATION; INVERTER; FILTER;
D O I
10.1109/ACCESS.2019.2944520
中图分类号
TP [自动化技术、计算机技术];
学科分类号
0812 ;
摘要
By adding Buck-type AC/AC converter to conventional power capacitor, dynamic capacitor (D-CAP) can be formed to compensate variable rather than fixed reactive power. However, some nonlinear distortion factors, namely grid harmonic voltage, voltage drop of switches and dead-time, would cause harmonics in its compensation current, meanwhile, its capacitance may interact with the grid inductance to cause series resonance. Both nonlinear distortion factors and series resonance would distort the waveform of its compensation current and make the grid current failed to meet the power quality standard IEEE Std.519. This paper focuses on the output current distortion of Buck-type D-CAP in reactive power compensation. For harmonic distortion, through establishing the equivalent circuit of Buck-type D-CAP, the generation of low-order harmonic current is investigated under three nonlinear factors. A current reshaping method to simultaneously diminish the harmonics caused by the three nonlinear distortion factors is thus adopted, which is a feedback control of output current harmonics. Then for series resonance, based on the block diagram of Buck-type D-CAP within the grid, transfer function from grid voltage to the output current is deduced and the corresponding Bode diagram is depicted. An active damping method is therefore suggested to shrink the low-order series resonance peak, by detecting power capacitors voltage for feedback control. Finally, a combined control, reactive current reshaping with series resonance damping is proposed in this paper for three-phase Buck-type D-CAP. A wide variety of experimental results from a 33kVar/220V laboratory prototype are provided to demonstrate the validity of the combined control.
引用
收藏
页码:142663 / 142674
页数:12
相关论文
共 50 条
  • [21] Three-phase single-stage four-switch PFC buck-boost-type rectifier
    Pires, VF
    Silva, JF
    IEEE TRANSACTIONS ON INDUSTRIAL ELECTRONICS, 2005, 52 (02) : 444 - 453
  • [22] Performance Analysis and Improvement of PI-Type Current Controller in Digital Average Current Mode Controlled Three-Phase Six-Switch Boost PFC Rectifier
    Geng, Xinghai
    Xu, Jianping
    Wang, Lei
    Chen, Zhengge
    Huang, Rui
    IEEE TRANSACTIONS ON POWER ELECTRONICS, 2022, 37 (07) : 7871 - 7882
  • [23] Research on methods of reactive compensation for unbalanced current in three-phase four-wire low-voltage distribution system
    Zhu, Xue-ling
    Cao, Wen-si
    Zhou, Xiao-ming
    RENEWABLE AND SUSTAINABLE ENERGY, PTS 1-7, 2012, 347-353 : 1156 - 1160
  • [24] Improved Capacitor Voltage Feedforward for Three-Phase LCL-Type Grid-Connected Converter to Suppress Start-Up Inrush Current
    Zhou, Shiying
    Zou, Xudong
    Zhu, Donghai
    Tong, Li
    Kang, Yong
    ENERGIES, 2017, 10 (05)
  • [25] Active Damping Scheme for Leakage Current Reduction in Transformerless Three-Phase Grid-Connected PV Inverters
    Giacomini, Julian C.
    Michels, Leandro
    Pinheiro, Humberto
    Rech, Cassiano
    IEEE TRANSACTIONS ON POWER ELECTRONICS, 2018, 33 (05) : 3988 - 3999
  • [26] A Decoupled Reference Generation Algorithm for Harmonic, Reactive Power and Current Unbalance Compensation in Three-phase Systems
    George, John
    Jose, T. L.
    Jacob, Jeevamma
    2011 ANNUAL IEEE INDIA CONFERENCE (INDICON-2011): ENGINEERING SUSTAINABLE SOLUTIONS, 2011,
  • [27] Capacitor Current Reduction in Dual Three-Phase PMSM Drive System by Model Predictive Control Considering Dead Time
    Sakauchi, Ryosuke
    Doki, Shinji
    Imai, Koji
    Kondo, Kosuke
    Aoki, Yasuaki
    2023 25TH EUROPEAN CONFERENCE ON POWER ELECTRONICS AND APPLICATIONS, EPE'23 ECCE EUROPE, 2023,
  • [28] Empowering Dynamic Active and Reactive Power Control: A Deep Reinforcement Learning Controller for Three-Phase Grid-Connected Electric Vehicles
    Ahmadian, Amirhossein
    Sedghisigarchi, Kourosh
    Gadh, Rajit
    IEEE ACCESS, 2024, 12 : 66068 - 66084
  • [29] Dynamic modeling and control system design of the buck-boost-based threestate three-phase Z-source inverter
    Cavalcanti, M. C.
    Bradaschia, F.
    de Melo Neto, M. T.
    Azevedo, G. M. S.
    Cardoso, T. D.
    INTERNATIONAL JOURNAL OF ELECTRICAL POWER & ENERGY SYSTEMS, 2019, 104 : 654 - 663
  • [30] Nonisolated Three-Phase Current DC-Link Buck-Boost EV Charger With Virtual Output Midpoint Grounding and Ground Current Control
    Zhang, Daifei
    Cao, Danqing
    Huber, Jonas
    Everts, Jordi
    Kolar, Johann W.
    IEEE TRANSACTIONS ON TRANSPORTATION ELECTRIFICATION, 2024, 10 (01): : 1398 - 1413