Silicon Photomultipliers in Scintillation Detectors Used For Gamma-Ray Energies Up to 6.1 MeV

被引:0
|
作者
Grodzicka, M. [1 ]
Szczesniak, T. [1 ]
Moszynski, M. [1 ]
Swiderski, L. [1 ]
Szawlowski, M. [1 ]
机构
[1] Natl Ctr Nucl Res, A Soltana 7, PL-05400 Otwock, Poland
来源
2015 IEEE NUCLEAR SCIENCE SYMPOSIUM AND MEDICAL IMAGING CONFERENCE (NSS/MIC) | 2015年
关键词
MPPC; energy resolution; linearity; dynamic range; scintillation detectors;
D O I
暂无
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
The aim of this paper is to study usefulness of SiPM light readout in detection of gamma rays up to 6.1MeV in combination with various scintillators. The reported measurements were made with 3 samples of one type of Hamamatsu TSV (Through Silicon Via technology) MPPC arrays. These 4x4 channel arrays have a 50x50 mu m(2) cell size and 12x12 mm(2) effective active area. All the tests were done in a climatic chamber. The following scintillators were used: CsI(Tl), CeBr3, NaI(Tl). The studies are focused on optimization of the MPPC performance for practical use in detection of high energy gamma rays. The optimization includes selection of the optimum operating voltage in respect to the energy resolution, verification of the dynamic range, linearity and pulse amplitude. The energy spectra for energies between 320keV and 6.1MeV are presented and compared with data acquired with a classic photomultiplier. Such comparison allowed study of nonlinearity of the tested MPPCs, correction of the energy spectra and proper analysis of the energy resolution. The temperature tests show strong breakdown voltage dependence on the temperature change and define requirements for the stabilization method in real life applications.
引用
收藏
页数:3
相关论文
共 50 条
  • [31] THE GAMMA-RAY SCINTILLATION SPECTROMETER
    PEIRSON, DH
    IREDALE, P
    BRITISH JOURNAL OF APPLIED PHYSICS, 1957, 8 (10): : 422 - 422
  • [32] GAMMA-RAY INDUCED SCINTILLATION
    ZHEMEREV, AV
    MEDVEDEV, YA
    SOVIET ATOMIC ENERGY-USSR, 1970, 29 (04): : 1014 - &
  • [33] GAMMA-RAY SCINTILLATION SPECTROMETRY
    COOK, CS
    AMERICAN SCIENTIST, 1957, 45 (03) : 245 - 262
  • [34] INFLUENCE OF TEMPERATURE ON SENSITIVITY OF SILICON SURFACE BARRIER DETECTORS USED FOR X-RAY AND GAMMA-RAY DOSIMETRY
    PETUSHKOV, AA
    PARKER, RP
    PHYSICS IN MEDICINE AND BIOLOGY, 1973, 18 (02): : 235 - 245
  • [35] DETERMINATION OF DETECTOR EFFICIENCIES FOR GAMMA-RAY ENERGIES UP TO 12 MEV .1. EXPERIMENTAL METHODS
    WAIBEL, E
    GROSSWENDT, B
    NUCLEAR INSTRUMENTS & METHODS, 1976, 131 (01): : 133 - 141
  • [36] THE BREMSSTRAHLUNG COMPONENT OF THE DIFFUSE GALACTIC GAMMA-RAY EMISSION AT MEV ENERGIES
    SACHER, W
    SCHONFELDER, V
    ASTROPHYSICAL JOURNAL, 1984, 279 (02): : 817 - 826
  • [37] METHODOLOGICAL ERRORS IN PRECISE MEASUREMENT OF GAMMA-RAY ENERGIES WITH GE DETECTORS
    KISHIKAWA, T
    JOURNAL OF NUCLEAR SCIENCE AND TECHNOLOGY, 1991, 28 (06) : 487 - 499
  • [38] An experimental method for a precise determination of gamma-ray energies with semiconductor detectors
    Vanin, VR
    Kenchian, G
    Moralles, M
    Helene, O
    Pascholati, PR
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 1997, 391 (02): : 338 - 344
  • [39] Gamma-ray Detection with a Large Silicon Detector in the MeV Range
    Brulin, G.
    Genolini, B.
    Dormard, J-J.
    Faul, I.
    Rauly, E.
    Rosier, P.
    de Sereville, N.
    Torrento, A.
    Le Ven, V.
    Wanlin, E.
    2016 IEEE NUCLEAR SCIENCE SYMPOSIUM, MEDICAL IMAGING CONFERENCE AND ROOM-TEMPERATURE SEMICONDUCTOR DETECTOR WORKSHOP (NSS/MIC/RTSD), 2016,
  • [40] New Development of Silicon Drift Detectors for Gamma-Ray Spectroscopy
    Fiorini, C.
    Bombelli, L.
    Busca, P.
    Peloso, R.
    Quaglia, R.
    Bellutti, P.
    Boscardin, M.
    Ficorella, F.
    Giacomini, G.
    Picciotto, A.
    Piemonte, C.
    Zorzi, N.
    2012 IEEE NUCLEAR SCIENCE SYMPOSIUM AND MEDICAL IMAGING CONFERENCE RECORD (NSS/MIC), 2012, : 2068 - 2074