The importance of surface air temperature fluctuations on long-term performance of vertical ground heat exchangers

被引:73
作者
Bidarmaghz, Asal [1 ]
Narsilio, Guillermo A. [1 ]
Johnston, Ian W. [1 ]
Colls, Stuart [2 ]
机构
[1] Univ Melbourne, Dept Infrastruct Engn, Parkville, Vic 3010, Australia
[2] Golder Associates Pty Ltd, Richmond, Australia
基金
澳大利亚研究理事会;
关键词
Numerical modelling; Surface air temperature variations; Ground temperature; Geothermal; Piles;
D O I
10.1016/j.gete.2016.02.003
中图分类号
TE [石油、天然气工业]; TK [能源与动力工程];
学科分类号
0807 ; 0820 ;
摘要
Ground source heat pump (GSHP) systems efficiently heat and cool buildings using geothermal energy accessed via ground heat exchangers (GHEs). The thermal performance of GHEs is usually studied with equivalent groups of linear heat sinks/sources or with more advanced numerical models. In most cases, in regions with common geothermal gradients, the ground temperature is assumed to be constant with depth, a simplification that is reasonable for typical borehole GHEs which are at least 50mdeep. However, the increasing use of piles (and other geo-structures) as GHEs, which are typically shallower than borehole GHEs requires a re-assessment of the thermal effects of the surface air temperature changes on GHEs. This work introduces and addresses such issues using the newly developed 3D detailed numerical model of GHEs and highlights its significant influence on thermal performance. Numerical results show that in the cases studied herein, accounting for the surface air temperature fluctuations may result in up to about 11% shorter GHEs than if these effects are ignored. (C) 2016 Elsevier Ltd. All rights reserved.
引用
收藏
页码:35 / 44
页数:10
相关论文
共 9 条
  • [1] Long-term study of vertical ground heat exchangers with varying seasonal heat fluxes
    Koohi-Fayegh, Seama
    Rosen, Marc A.
    GEOTHERMICS, 2018, 75 : 15 - 25
  • [2] Equivalent energy wave for long-term analysis of ground coupled heat exchangers
    Abdelaziz, Sherif L.
    Olgun, C. Guney
    Martin, James R., II
    GEOTHERMICS, 2015, 53 : 67 - 84
  • [3] Thermal performance and ground temperature of vertical pile-foundation heat exchangers: A case study
    Gao, Jun
    Zhang, Xu
    Liu, Jun
    Li, Kui Shan
    Yang, Jie
    APPLIED THERMAL ENGINEERING, 2008, 28 (17-18) : 2295 - 2304
  • [4] Long-Term Temperature Evaluation of a Ground-Coupled Heat Pump System Subject to Groundwater Flow
    Jaziri, Nehed
    Raymond, Jasmin
    Giordano, Nicolo
    Molson, John
    ENERGIES, 2020, 13 (01)
  • [5] Heat transfer performance of buried extremely long ground-coupled heat exchangers with concentric pipes
    Jia, Guosheng
    Chai, John C.
    Zhou, Cong
    Zhao, Min
    Tao, Zeyu
    Zhang, Lianying
    Yang, Xiaohu
    Meng, Xiangzhao
    Jin, Liwen
    LEVERAGING ENERGY TECHNOLOGIES AND POLICY OPTIONS FOR LOW CARBON CITIES, 2017, 143 : 106 - 111
  • [6] Evaluation of an integrated sewage pipe with ground heat exchanger for long-term efficiency estimation
    Dacquay, Connor
    Hollander, Hartmut M.
    Kavgic, Miroslava
    Maghoul, Pooneh
    Liu, Hongwei
    Fujii, Hikari
    GEOTHERMICS, 2020, 86 (86)
  • [7] Influences of seasonal changes of the ground temperature on the performance of ground heat exchangers embedded in diaphragm walls: A cold climate case from North China
    Xu, Yishuo
    Guo, Yanlong
    Wang, Huajun
    Wang, Bo
    Zhao, Yanting
    Shen, Jian
    RENEWABLE ENERGY, 2023, 217
  • [8] Long-range correlation behaviors for the 0-cm average ground surface temperature and average air temperature over China
    Lei Jiang
    Nana Li
    Zuntao Fu
    Jiping Zhang
    Theoretical and Applied Climatology, 2015, 119 : 25 - 31
  • [9] Long-term performance of an irregular shaped borehole heat exchanger system: Analysis of real pattern and regular grid approximation
    Teza, Giordano
    Galgaro, Antonio
    De Carli, Michele
    GEOTHERMICS, 2012, 43 : 45 - 56