Anisotropy of collagen fiber orientation in sheep tendon by 1H double-quantum-filtered NMR signals

被引:44
作者
Fechete, R
Demco, DE
Blümich, B
Eliav, U
Navon, G
机构
[1] Rhein Westfal TH Aachen, Inst Tech Chem & Makromol Chem, D-52056 Aachen, Germany
[2] Tel Aviv Univ, Sch Chem, IL-69978 Tel Aviv, Israel
关键词
anisotropy of the residual dipolar coupling; H-1 double-quantum-filtered NMR signal; tendon; orientation distribution of collagen fibrils;
D O I
10.1016/S1090-7807(02)00200-8
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
The anisotropy of the angular distribution of collagen fibrils in a sheep tendon was investigated by H-1 double-quantum (DQ) filtered NMR signals. Double-quantum build-up curves generated by the five-pulse sequence were measured for different angles between the direction of the static magnetic field and the axis of the tendon plug. Proton residual dipolar couplings determined from the DQ build-up curves in the initial excitation/reconversion time regime which mainly represent the bound water are interpreted in terms of a model of spin-1/2 pairs with their internuclear axes oriented on average along the fibril direction in the presence of proton exchange. The angular distribution of collagen fibrils around the symmetry axis of the tendon measured by the anisotropy of the residual dipolar couplings was described by a Gaussian function with a standard deviation of 12degrees +/- 1degrees and with the center of the distribution at 4degrees +/- 1degrees. The existence of this distribution is directly reflected in the finite value of the residual dipolar couplings at the magic angle, the value of the angular contrast, and the oscillatory behavior of the DQ build-up curves. The H-1 residual dipolar couplings were also measured from the doublets recorded by the DQ-filtered signals. From the angular dependence of the normalized splitting the angular distribution of the collagen fibrils was evaluated using a Gaussian function with a standard deviation of 19degrees +/- 1degrees and with the center of distribution at 2degrees +/- 1degrees. The advantages and disadvantages of these approaches are discussed. (C) 2003 Elsevier Science (USA). All rights reserved.
引用
收藏
页码:166 / 175
页数:10
相关论文
共 25 条
  • [11] Detection of sodium ions in anisotropic environments through spin-lock NMR
    Hancu, I
    van der Maarel, JRC
    Boada, FE
    [J]. MAGNETIC RESONANCE IN MEDICINE, 2002, 47 (01) : 68 - 74
  • [12] Hanstock CC, 1999, MAGN RESON MED, V42, P421, DOI 10.1002/(SICI)1522-2594(199909)42:3<421::AID-MRM2>3.0.CO
  • [13] 2-6
  • [14] ANISOTROPY OF NMR PROPERTIES OF TISSUES
    HENKELMAN, RM
    STANISZ, GJ
    KIM, JK
    BRONSKILL, MJ
    [J]. MAGNETIC RESONANCE IN MEDICINE, 1994, 32 (05) : 592 - 601
  • [15] KEMPHARPER R, 1999, J MAGN RESON SER B, V107, P60
  • [16] LIQUID-CRYSTAL-LIKE STRUCTURES OF HUMAN MUSCLE DEMONSTRATED BY IN-VIVO OBSERVATION OF DIRECT DIPOLAR COUPLING IN LOCALIZED PROTON MAGNETIC-RESONANCE SPECTROSCOPY
    KREIS, R
    BOESCH, C
    [J]. JOURNAL OF MAGNETIC RESONANCE SERIES B, 1994, 104 (02): : 189 - 192
  • [17] MUNOWITZ M, 1987, ADV CHEM PHYS, V66, P1
  • [18] Multiquantum filters and order in tissues
    Navon, G
    Shinar, H
    Eliav, U
    Seo, Y
    [J]. NMR IN BIOMEDICINE, 2001, 14 (02) : 112 - 132
  • [19] FIBER-TO-FIELD ANGLE DEPENDENCE OF PROTON NUCLEAR MAGNETIC-RELAXATION IN COLLAGEN
    PETO, S
    GILLIS, P
    [J]. MAGNETIC RESONANCE IMAGING, 1990, 8 (06) : 705 - 712
  • [20] Residual dipolar couplings by 1H dipolar-encoded longitudinal magnetization, double- and triple-quantum nuclear magnetic resonance in cross-linked elastomers
    Schneider, M
    Gasper, L
    Demco, DE
    Blümich, B
    [J]. JOURNAL OF CHEMICAL PHYSICS, 1999, 111 (01) : 402 - 415