Highly efficient detection in fluorescence tomography of quantum dots using time-gated acquisition and ultrafast pulsed laser
被引:2
|
作者:
Zhang, Xiaofeng
论文数: 0引用数: 0
h-index: 0
机构:
Duke Univ, Med Ctr, Ctr Vivo Microscopy, Durham, NC 27710 USADuke Univ, Med Ctr, Ctr Vivo Microscopy, Durham, NC 27710 USA
Zhang, Xiaofeng
[1
]
Badea, Cristian T.
论文数: 0引用数: 0
h-index: 0
机构:
Duke Univ, Med Ctr, Ctr Vivo Microscopy, Durham, NC 27710 USADuke Univ, Med Ctr, Ctr Vivo Microscopy, Durham, NC 27710 USA
Badea, Cristian T.
[1
]
机构:
[1] Duke Univ, Med Ctr, Ctr Vivo Microscopy, Durham, NC 27710 USA
来源:
OPTICAL TOMOGRAPHY AND SPECTROSCOPY OF TISSUE IX
|
2011年
/
7896卷
关键词:
fluorescence tomography;
time-gate acquisition;
quantum dot;
LIVE CELLS;
LIGHT;
MICE;
D O I:
10.1117/12.875502
中图分类号:
O43 [光学];
学科分类号:
070207 ;
0803 ;
摘要:
Quantum dots (QDs) are widely used in fluorescence tomography due to its unique advantages. Despite the very high quantum efficiency of the QDs, low fluorescent signal and autofluorescence are the most fundamental limitations in optical data acquisition. These limitations are particularly detrimental to image reconstruction for animal imaging, e.g., free-space in vivo fluorescence tomography. In animals studies, fluorescent emission from exogenous fluorescent probes (e.g. QDs) cannot be effectively differentiated from endogenous broad-spectral substances (mostly proteins) using optical filters. In addition, a barrow-band fluorescent filter blocks the majority of the fluorescent light and thus makes signal acquisition very inefficient. We made use of the long fluorescent lifetime of the QDs to reject the optical signal due to the excitation light pulse, and therefore eliminated the need for a fluorescent filter during acquisition. Fluorescent emission from the QDs was excited with an ultrafast pulsed laser, and was detected using a time-gated image intensifier. A tissue-simulating imaging phantom was used to validate the proposed method. Compared to the standard acquisition method that uses a narrow-band fluorescent filter, the proposed method is significantly more efficient in data acquisition (by a factor of >10 in terms of fluorescent signal intensity) and demonstrated reduction in autofluorescence. No additional imaging artifact was observed in the tomographic reconstruction.
机构:
GE Global Res, Niskayuna, NY 12309 USAGE Global Res, Niskayuna, NY 12309 USA
May, Andrzej
Bhaumik, Srabani
论文数: 0引用数: 0
h-index: 0
机构:
GE Global Res, Niskayuna, NY 12309 USAGE Global Res, Niskayuna, NY 12309 USA
Bhaumik, Srabani
Gambhir, Sanjiv S.
论文数: 0引用数: 0
h-index: 0
机构:
Stanford Univ, Dept Radiol, Mol Imaging Program, Palo Alto, CA 94305 USA
Stanford Univ, Biox Program, Dept Bioengn, Palo Alto, CA 94305 USAGE Global Res, Niskayuna, NY 12309 USA
Gambhir, Sanjiv S.
Zhan, Chun
论文数: 0引用数: 0
h-index: 0
机构:
GE Global Res, Niskayuna, NY 12309 USAGE Global Res, Niskayuna, NY 12309 USA
Zhan, Chun
Yazdanfar, Siavash
论文数: 0引用数: 0
h-index: 0
机构:
GE Global Res, Niskayuna, NY 12309 USAGE Global Res, Niskayuna, NY 12309 USA