Effect of thermocycling with or without 1 year of water storage on retentive strengths of luting cements for zirconia crowns

被引:22
作者
Ehlers, Vicky [1 ]
Kampf, Gabriel [1 ]
Stender, Elmar [2 ]
Willershausen, Brita [1 ]
Ernst, Claus-Peter [1 ]
机构
[1] Johannes Gutenberg Univ Mainz, Dept Operat Dent, Univ Med Ctr, D-55131 Mainz, Germany
[2] Johannes Gutenberg Univ Mainz, Inst Mat Sci & Technol, Univ Med Ctr, D-55131 Mainz, Germany
关键词
OXIDE CERAMIC CROWNS; FLEXURAL STRENGTH; BOND STRENGTH; RESIN;
D O I
10.1016/j.prosdent.2014.12.001
中图分类号
R78 [口腔科学];
学科分类号
1003 ;
摘要
Statement of problem. Bond stability between zirconia crowns and luting cement and between cement and dentin is a main concern; however, only limited evidence is available as to its longevity. Purpose. The purpose of this in vitro study was to measure the retentive strengths of 7 self-adhesive cements (RelyX Unicem Aplicap, RelyX Unicem Clicker, RelyX Unicem 2 Automix, iCEM, Maxcem Elite, Bifix SE, SpeedCem), 2 adhesive cements with self-etch primers (Panavia 21, SEcure), 1 glass ionomer cement (Ketac Cem), 1 resin-modified glass ionomer cement (Meron Plus), and 1 zinc phosphate cement for luting zirconia crowns (LAVA) to extracted teeth after thermocycling with or without 1 year of water storage. Material and methods. Two-hundred-forty extracted human molars (2 treatments; n=10 per cement) were prepared in a standardized manner. All cements were used according to the manufacturers' recommendations. The intaglios of the crowns were treated with airborne-particle abrasion. After thermocycling (x5000, 5 degrees C/55 degrees C) with or without 1 year of water storage, the cemented ceramic crowns were removed by using a Zwick universal testing device. Statistical analyses were done with the Wilcoxon rank sum and the 2-independent-samples Kolmogorov-Smirnov test. Results. Median retentive strengths [MPa] for specimens thermocycled only/thermocycled with 1 year of water storage were as follows: Panavia 21:1.7/2.5, SEcure: 3.0/3.0, RelyX Unicem Aplicap: 3.1/3.4, RelyX Unicem Clicker: 4.1/4.2, RelyX Unicem 2 Automix: 3.8/3.1, iCEM: 2.3/2.7, Maxcem Elite: 3.0/3.2, Bifix SE: 1.7/1.7, SpeedCem: 1.3/1.6, Meron Plus: 3.1/2.7, Ketac Cem: 1.4/1.4, and zinc phosphate cement: 1.1/1.6. Statistically significant differences were found only among specimens thermocycled only or thermocycled with 1-year water storage (P<.001). Conclusions. Significant differences in retentive strengths were observed among cements after thermocycling only or thermocycling with 1 year of water storage, but not for the effect of the additional 1 year of water storage.
引用
收藏
页码:609 / 615
页数:7
相关论文
共 27 条
[1]   Transformation-toughened zirconia for dental inlays, crowns and bridges: chemical stability and effect of low-temperature aging on flexural strength and surface structure [J].
Ardlin, BI .
DENTAL MATERIALS, 2002, 18 (08) :590-595
[2]   Resin-ceramic bonding: a review of the literature [J].
Blatz, MB ;
Sadan, A ;
Kern, M .
JOURNAL OF PROSTHETIC DENTISTRY, 2003, 89 (03) :268-274
[3]  
Burke F J Trevor, 2002, J Adhes Dent, V4, P7
[4]   Effect of surface pre-treatments on the zirconia ceramic-resin cement microtensile bond strength [J].
Casucci, Alessio ;
Monticelli, Francesca ;
Goracci, Cecilia ;
Mazzitelli, Claudia ;
Cantoro, Amerigo ;
Papacchini, Federica ;
Ferrari, Marco .
DENTAL MATERIALS, 2011, 27 (10) :1024-1030
[5]   CURING LIGHT-ACTIVATED COMPOSITE CEMENT THROUGH PORCELAIN [J].
CHAN, KC ;
BOYER, DB .
JOURNAL OF DENTAL RESEARCH, 1989, 68 (03) :476-480
[6]  
Chong KH, 2002, INT J PROSTHODONT, V15, P183
[7]   RETENTIVE PROPERTIES OF LUTING CEMENTS - AN INVITRO INVESTIGATION [J].
DAHL, BL ;
OILO, G .
DENTAL MATERIALS, 1986, 2 (01) :17-20
[8]  
Derand T, 2008, EUR J PROSTHODONT RE, V16, P35
[9]  
Ernst CP, 2009, AM J DENT, V22, P122
[10]   In vitro retentive strength of zirconium oxide ceramic crowns using different luting agents [J].
Ernst, CP ;
Doz, P ;
Cohnen, U ;
Stender, E ;
Willershausen, B .
JOURNAL OF PROSTHETIC DENTISTRY, 2005, 93 (06) :551-558