Intravascular ultrasound (US) elastography reveals the elastic properties of vascular tissue and plaque. However, misalignment of the US catheter in the vessel lumen can cause incorrect strain estimation in intravascular US elastography caused by strain projection artifacts. In this paper, we present a general theoretical solution where the impact of catheter eccentricity, tilt and noncoplanar errors on the strain estimates are derived. Appropriate corrections to strain estimates can then be applied with prior knowledge of the catheter position information to reduce the strain projection artifacts. Simulations using a frequency-domain-based algorithm that models intravascular US imaging before and after a specified deformation are presented. The simulations are used to verify the theoretical derivations for two displacement situations (linear and nonlinear) under intraluminal pressure, with and without stress decay. The linear displacement case demonstrates that the correction factor is dependent only on the angle between the US beam and the cross-sectional plane of the vessel. For the nonlinear displacement case, where a l/r stress decay in the displacement is modeled, the correction factor becomes a more complicated function of the azimuthal angle. (E-mail: tvarghese@wisc.edu) (C) 2005 World Federation for Ultrasound in Medicine & Biology.
引用
收藏
页码:1509 / 1526
页数:18
相关论文
共 30 条
[1]   Parametric (integrated backscatter and attenuation) images constructed using backscattered radio frequency signals (25-56 MHz) from human aortae in vitro [J].
Bridal, SL ;
Fornes, P ;
Bruneval, P ;
Berger, G .
ULTRASOUND IN MEDICINE AND BIOLOGY, 1997, 23 (02) :215-229
[2]   Correlation of ultrasonic attenuation (30 to 50 mhz) and constituents of atherosclerotic plaque [J].
Bridal, SL ;
Fornes, P ;
Bruneval, P ;
Berger, G .
ULTRASOUND IN MEDICINE AND BIOLOGY, 1997, 23 (05) :691-703
[3]   Effects of transducer position on backscattered intensity in coronary arteries [J].
Courtney, BK ;
Robertson, AL ;
Maehara, A ;
Luna, J ;
Kitamura, K ;
Morino, Y ;
Achalu, R ;
Kirti, S ;
Yock, PG ;
Fitzgerald, PJ .
ULTRASOUND IN MEDICINE AND BIOLOGY, 2002, 28 (01) :81-91
[4]  
de Korte C L, 1998, Eur J Ultrasound, V7, P219, DOI 10.1016/S0929-8266(98)00043-3
[5]   Identification of atherosclerotic plaque components with intravascular ultrasound elastography in vivo A Yucatan pig study [J].
de Korte, CL ;
Sierevogel, MJ ;
Mastik, F ;
Strijder, C ;
Schaar, JA ;
Velema, E ;
Pasterkamp, G ;
Serruys, PW ;
van der Steen, AFW .
CIRCULATION, 2002, 105 (14) :1627-1630
[6]   Influence of catheter position on estimated strain in intravascular elastography [J].
de Korte, CL ;
Céspedes, EI ;
van der Steen, AFW .
IEEE TRANSACTIONS ON ULTRASONICS FERROELECTRICS AND FREQUENCY CONTROL, 1999, 46 (03) :616-625
[7]   Characterization of plaque components and vulnerability with intravascular ultrasound elastography [J].
de Korte, CL ;
van der Steen, AFW ;
Céspedes, EI ;
Pasterkamp, G ;
Carlier, SG ;
Mastik, F ;
Schoneveld, AH ;
Serruys, PW ;
Bom, N .
PHYSICS IN MEDICINE AND BIOLOGY, 2000, 45 (06) :1465-1475
[8]   Characterization of plaque components with intravascular ultrasound elastography in human femoral and coronary arteries in vitro [J].
de Korte, CL ;
Pasterkamp, G ;
van der Steen, AFW ;
Woutman, HA ;
Bom, N .
CIRCULATION, 2000, 102 (06) :617-623
[9]   ARTERIAL-WALL CHARACTERISTICS DETERMINED BY INTRAVASCULAR ULTRASOUND IMAGING - AN INVITRO STUDY [J].
GUSSENHOVEN, EJ ;
ESSED, CE ;
LANCEE, CT ;
MASTIK, F ;
FRIETMAN, P ;
VANEGMOND, FC ;
REIBER, J ;
BOSCH, H ;
VANURK, H ;
ROELANDT, J ;
BOM, N .
JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 1989, 14 (04) :947-952
[10]  
GUSSENHOVEN WJ, 1989, EUR J VASCULAR SURG, V3, P571