Sensitivity of Photon-Counting Based K-Edge Imaging in X-ray Computed Tomography

被引:99
作者
Roessl, Ewald [1 ]
Brendel, Bernhard [1 ]
Engel, Klaus-Juergen [2 ]
Schlomka, Jens-Peter [1 ]
Thran, Axel [1 ]
Proksa, Roland [1 ]
机构
[1] Philips Res Europe Hamburg, D-22335 Hamburg, Germany
[2] Philips Res Europe Aachen, D-52066 Aachen, Germany
关键词
Computed tomography (CT); photon-counting; spectral K-edge imaging; PULSE PILEUP; DETECTOR; NOISE; MODEL;
D O I
10.1109/TMI.2011.2142188
中图分类号
TP39 [计算机的应用];
学科分类号
081203 ; 0835 ;
摘要
The feasibility of K-edge imaging using energy-resolved, photon-counting transmission measurements in X-ray computed tomography (CT) has been demonstrated by simulations and experiments. The method is based on probing the discontinuities of the attenuation coefficient of heavy elements above and below the K-edge energy by using energy-sensitive, photon counting X-ray detectors. In this paper, we investigate the dependence of the sensitivity of K-edge imaging on the atomic number of the contrast material, on the object diameter, on the spectral response of the X-ray detector and on the X-ray tube voltage. We assume a photon-counting detector equipped with six adjustable energy thresholds. Physical effects leading to a degradation of the energy resolution of the detector are taken into account using the concept of a spectral response function R(e, U) for which we assume four different models. As a validation of our analytical considerations and in order to investigate the influence of elliptically shaped phantoms, we provide CT simulations of an anthropomorphic Forbild-Abdomen phantom containing a gold-contrast agent. The dependence on the values of the energy thresholds is taken into account by optimizing the achievable signal-to-noise ratios (SNR) with respect to the threshold values. We find that for a given X-ray spectrum and object size the SNR in the heavy element's basis material image peaks for a certain atomic number. The dependence of the SNR in the high-basis-material image on the object diameter is the natural, exponential decrease with particularly deteriorating effects in the case where the attenuation from the object itself causes a total signal loss below the K-edge. The influence of the energy-response of the detector is very important. We observed that the optimal SNR values obtained with an ideal detector and with a CdTe pixel detector whose response, showing significant tailing, has been determined at a synchrotron differ by factors of about two to three. The potentially very important impact of scattered X-ray radiation and pulse pile-up occurring at high photon rates on the sensitivity of the technique is qualitatively discussed.
引用
收藏
页码:1678 / 1690
页数:13
相关论文
共 26 条
[1]   ENERGY-SELECTIVE RECONSTRUCTIONS IN X-RAY COMPUTERIZED TOMOGRAPHY [J].
ALVAREZ, RE ;
MACOVSKI, A .
PHYSICS IN MEDICINE AND BIOLOGY, 1976, 21 (05) :733-744
[2]  
[Anonymous], P SPIE MED IM C
[3]  
[Anonymous], P SPIE MED IM C
[4]  
[Anonymous], 1987, PRINCIPLES COMPUTERI
[5]  
[Anonymous], P IEEE NUCL SCI S C
[6]  
[Anonymous], 1992, Photon, electron, proton and neutron interaction data for body tissues., P46
[7]  
[Anonymous], THESIS LINKOPING U L
[8]   Testing an energy-dispersive counting-mode detector with hard x-rays from a synchrotron source [J].
Baeumer, Christian ;
Martens, Gerhard ;
Menser, Bernd ;
Roessl, Ewald ;
Schlomka, Jens-Peter ;
Steadman, Roger ;
Zeitler, Guenter .
IEEE TRANSACTIONS ON NUCLEAR SCIENCE, 2008, 55 (03) :1785-1790
[9]  
Cowan G., 1998, STAT DATA ANAL
[10]   Spectral analysis of scattered radiation in CT [J].
Engel, Klaus J. ;
Baeumer, Christian ;
Wiegert, Jens ;
Zeitler, Guenter .
MEDICAL IMAGING 2008: PHYSICS OF MEDICAL IMAGING, PTS 1-3, 2008, 6913 :R9131-R9131