An experimental study on liquid regeneration process of a liquid desiccant air conditioning system (LDACs) based on vacuum membrane distillation

被引:33
|
作者
Zhou, Junming [1 ,2 ]
Wang, Faming [2 ,3 ]
Noor, Nuruzzaman [2 ]
Zhang, Xiaosong [1 ]
机构
[1] Southeast Univ, Sch Energy & Environm, Nanjing, Peoples R China
[2] Hong Kong Polytech Univ, Inst Text & Clothing, Mat Synth & Proc Lab, Hung Hom,Kowloon, Hong Kong, Peoples R China
[3] Cent South Univ, Sch Architecture & Art, Changsha, Peoples R China
基金
中国国家自然科学基金;
关键词
Liquid dehumidification; Experiment; VMD; Regeneration ability; SEAWATER DESALINATION; PERFORMANCE ANALYSIS; SIMULATION;
D O I
10.1016/j.energy.2019.116891
中图分类号
O414.1 [热力学];
学科分类号
摘要
In this paper, a liquid regeneration method by vacuum membrane distillation (VMD) is proposed for the liquid desiccant air conditioning system (LDAC5), and the experimental study on this method is carried out. VMD regeneration experiments were carried out with LiCl solution. The effects of temperature, concentration of feed solution, length, number of fiber membranes and vacuum pressure on the membrane flux, mass transfer coefficient, rejection rate and regeneration ability were studied. The results show that the error between experimental and calculation results is reduced from less than 15% to less than 5% by the optimized calculation model. The temperature of feed solution has a great influence on the regeneration performance of VMD, and the regeneration ability of VMD process increases approximately exponentially from about 0.1% to 0.8-1.2% with the increase of regeneration temperature. The VMD regeneration process of LiCl solution is the result of Poiseuille flow and Knudsen diffusion, and Poiseuille flow dominates. Under the same regeneration capacity, the regeneration temperature of 30 wt % LiCl solution is about 7 degrees C higher than that of 20 wt% LiCl solution, and this temperature difference also increases as the target regeneration amount increases. In order to improve the regeneration effect of high concentration solution, the regeneration temperature can be increased appropriately. The water flux of the membrane decreases with the increase of the length of the membrane. The membrane length of Typel is 2.1 times longer than Type 2, but regeneration capacity of Type 1 is only 1-1.7 times higher than Type 2. Further, both the water flux and regeneration ability of the solution decrease first and then increase with the increasing number of membranes. Therefore, the reasonable selection of number of fiber membranes can significantly save materials and also improve the regeneration ability. (C) 2020 Elsevier Ltd. All rights reserved.
引用
收藏
页数:9
相关论文
共 50 条
  • [1] Experimental Study on Vacuum Membrane Distillation Liquid Regeneration of Liquid Desiccant Air Conditioning System
    Zhou, Jun-Ming
    Zhang, Xiao-Song
    Kung Cheng Je Wu Li Hsueh Pao/Journal of Engineering Thermophysics, 2020, 41 (11): : 2635 - 2640
  • [2] Liquid desiccant lithium chloride regeneration by membrane distillation for air conditioning
    Duong, Hung C.
    Hai, Faisal I.
    Al-Jubainawi, Ali
    Ma, Zhenjun
    He, Tao
    Nghiem, Long D.
    SEPARATION AND PURIFICATION TECHNOLOGY, 2017, 177 : 121 - 128
  • [3] Performance analysis of vacuum membrane distillation regenerator in liquid desiccant air conditioning system
    Zhou, Junming
    Zhang, Xiaosong
    Su, Wei
    Sun, Bo
    INTERNATIONAL JOURNAL OF REFRIGERATION-REVUE INTERNATIONALE DU FROID, 2019, 102 : 112 - 121
  • [4] Theoretical and experimental study of multi-effect vacuum membrane distillation systems for liquid desiccant air conditioning and zero liquid discharge
    Kiefer, Florian
    Schummer, Florian
    Praebst, Alexander
    Spinnler, Markus
    Sattelmayer, Thomas
    DESALINATION AND WATER TREATMENT, 2017, 69 : 190 - 201
  • [5] Desiccant solutions, membrane technologies, and regeneration techniques in liquid desiccant air conditioning system
    Oladosu, Temidayo Lekan
    Baheta, Aklilu Tesfamichael
    Oumer, Ahmed N.
    INTERNATIONAL JOURNAL OF ENERGY RESEARCH, 2021, 45 (06) : 8420 - 8447
  • [6] Modeling of a flat plate membrane-distillation system for liquid desiccant regeneration in air-conditioning applications
    Rattner, Alexander S.
    Nagavarapu, Ananda Krishna
    Garimella, Srinivas
    Fuller, Thomas F.
    INTERNATIONAL JOURNAL OF HEAT AND MASS TRANSFER, 2011, 54 (15-16) : 3650 - 3660
  • [7] Membrane Processes for the Regeneration of Liquid Desiccant Solution for Air Conditioning
    Hung Cong Duong
    Ashley Joy Ansari
    Long Duc Nghiem
    Hai Thuong Cao
    Thao Dinh Vu
    Thao Phuong Nguyen
    Current Pollution Reports, 2019, 5 : 308 - 318
  • [8] Membrane Processes for the Regeneration of Liquid Desiccant Solution for Air Conditioning
    Duong, Hung Cong
    Ansari, Ashley Joy
    Nghiem, Long Duc
    Cao, Hai Thuong
    Vu, Thao Dinh
    Nguyen, Thao Phuong
    CURRENT POLLUTION REPORTS, 2019, 5 (04) : 308 - 318
  • [9] Membrane distillation to regenerate different liquid desiccant solutions for air conditioning
    Duong, Hung C.
    Alvarez, Ivan R. C.
    Nguyen, Tinh V.
    Nghiem, Long D.
    DESALINATION, 2018, 443 : 137 - 142
  • [10] Experimental comparative research on electrodialysis regeneration for liquid desiccant with different concentrations in liquid desiccant air-conditioning system
    Cheng, Qing
    Zhang, Xiaosong
    Jiao, Shun
    ENERGY AND BUILDINGS, 2017, 155 : 475 - 483