Systematic Evaluation of Tumoral 99mTc-MAA Uptake Using SPECT and SPECT/CT in 502 Patients Before 90Y Radioembolization

被引:17
作者
Ilhan, Harun [1 ]
Goritschan, Anna [1 ]
Paprottka, Phillip [2 ]
Jakobs, Tobias F. [3 ]
Fendler, Wolfgang P. [1 ]
Bartenstein, Peter [1 ]
Hacker, Marcus [1 ,4 ]
Haug, Alexander R. [1 ,4 ]
机构
[1] Univ Munich, Dept Nucl Med, Munich, Germany
[2] Univ Munich, Inst Clin Radiol, Munich, Germany
[3] Krankenhaus Barmherzige Bruder, Dept Diagnost & Intervent Radiol, Munich, Germany
[4] Univ Vienna, Dept Biomed Imaging & Image Guided Therapy, Div Nucl Med, A-1090 Vienna, Austria
关键词
SPECT/CT; radioembolization; MAA uptake; oncology; HEPATOCELLULAR-CARCINOMA; MICROSPHERES; DOSIMETRY; SURVIVAL; PREDICTS;
D O I
10.2967/jnumed.114.150565
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
The aim of this study was to evaluate the Tc-99m-macroaggregated albumin (Tc-99m-MAA) uptake of primary and secondary liver tumors in a large patient cohort before Y-90 radioembolization. Methods: We included 502 patients during the years 2005-2013 (55% male; mean age, 62 +/- 11 y), who were examined with Tc-99m-MAA SPECT or SPECT/CT before planned radioembolization. The patients had colorectal cancer (CRC; n = 195, 38.8%), neuroendocrine tumors (NET; n = 77, 15.3%), mammary cancer (MAM; n = 68, 13.5%), hepatocellular carcinoma (HCC; n = 59, 11.8%), cholangiocellular carcinoma (CCC; n = 40, 8.0%), or urologic tumors (URO; n = 14, 2.8%). SPECT with coregistered contrast-enhanced CT or MR imaging and SPECT/CT images of these patients were analyzed using dedicated software with regard to the Tc-99m-MAA uptake of the liver tumors. Regions of interest were drawn around the lesions manually and quantified the uptake of up to 3 lesions per patient and also adjacent healthy liver tissue without evidence of tumor. We quantified maximum and mean counts per pixel and calculated tumor-to-background ratio (TBR). Data are reported as mean +/- SD. Lesion uptake was classified as being homogeneously high (grade 1), heterogeneously high (grade 2), equal to that of the liver (grade 3), or low (grade 4). Results: Grade 1 uptake was seen in 230 of 1,008 lesions (with the highest rates in sarcoma [47%], MAM [37%], and NET [32%]), grade 2 in 706 lesions (with the highest rates in CRC [77%], HCC [75%], and CCC [74%]), grade 4 in 57 lesions (with the highest rates in pancreatic cancer [17%], sarcoma [SAR] [13%], and MAM [8%]), and grade 3 in only 15 lesions. In quantitative analysis, the mean TBRmax of all lesions was 4.8 +/- 4.1 (range, 0.2-50.1), with the highest values in HCC (6.0 +/- 4.7; range, 1.4-21.6), NET (5.4 +/- 4.9; range, 0.8-43.0), pancreatic cancer (4.0 +/- 2.8; range, 0.9-12.2), and CCC (4.7 +/- 2.9; range, 0.9-11.6), and the lowest values in SAR (3.5 +/- 1.8; range, 0.8-2.7) and MAM (3.6 +/- 2.2; range, 0.9-11.6). The mean TBRmean was 1.9 +/- 1.0 (range, 0.1-7.2), with the highest values in NET (2.2 +/- 1.2; range, 0.2-7.2), HCC (2.1 +/- 1.2; range, 0.3-6.3), and CCC (2.0 +/- 1.0; range, 0.2-6.3) and the lowest values in MAM (1.7 +/- 0.8; range, 0.2-4.1), CRC (1.8 +/- 0.9; range, 0.4-6.6), and SAR (1.7 +/- 1.1; range, 0.3-3.9). Conclusion: The Tc-99m-MAA uptake of different tumor entities shows a wide variation, with generally highest values for NET, HCC, and CCC and lowest values for MAM, CRC, and SAR. However, the variation of uptake within the different tumor entities is high.
引用
收藏
页码:333 / 338
页数:6
相关论文
共 16 条
[1]   99mTc-MAA/90Y-Bremsstrahlung SPECT/CT after simultaneous Tc-MAA/90Y-microsphere injection for immediate treatment monitoring and further therapy planning for radioembolization [J].
Ahmadzadehfar, Hojjat ;
Sabet, Amir ;
Muckle, Marianne ;
Wilhelm, Kai ;
Reichmann, Karl ;
Biersack, Hans-Juergen ;
Ezziddin, Samer .
EUROPEAN JOURNAL OF NUCLEAR MEDICINE AND MOLECULAR IMAGING, 2011, 38 (07) :1281-1288
[2]   The Significance of 99mTc-MAA SPECT/CT Liver Perfusion Imaging in Treatment Planning for 90Y-Microsphere Selective Internal Radiation Treatment [J].
Ahmadzadehfar, Hojjat ;
Sabet, Amir ;
Biermann, Kim ;
Muckle, Marianne ;
Brockmann, Holger ;
Kuhl, Christiane ;
Wilhelm, Kai ;
Biersack, Hans-Juergen ;
Ezziddin, Samer .
JOURNAL OF NUCLEAR MEDICINE, 2010, 51 (08) :1206-1212
[3]  
Dhabuwala Atul, 2005, BMC Nucl Med, V5, P7, DOI 10.1186/1471-2385-5-7
[4]   Dosimetry Based on 99mTc-Macroaggregated Albumin SPECT/CT Accurately Predicts Tumor Response and Survival in Hepatocellular Carcinoma Patients Treated with 90Y-Loaded Glass Microspheres: Preliminary Results [J].
Garin, Etienne ;
Lenoir, Laurence ;
Rolland, Yan ;
Edeline, Julien ;
Mesbah, Habiba ;
Laffont, Sophie ;
Poree, Philippe ;
Clement, Bruno ;
Raoul, Jean-Luc ;
Boucher, E. .
JOURNAL OF NUCLEAR MEDICINE, 2012, 53 (02) :255-263
[5]   SPECT/CT with 99mTc-MAA in Radioembolization with 90Y Microspheres in Patients with Hepatocellular Cancer [J].
Hamami, Monia E. ;
Poeppel, Thorsten D. ;
Mueller, Stephan ;
Heusner, Till ;
Bockisch, Andreas ;
Hilgard, Philipp ;
Antoch, Gerald .
JOURNAL OF NUCLEAR MEDICINE, 2009, 50 (05) :688-692
[6]   18F-FDG PET independently predicts survival in patients with cholangiocellular carcinoma treated with 90Y microspheres [J].
Haug, Alexander R. ;
Heinemann, Volker ;
Bruns, Christiane J. ;
Hoffmann, Ralf ;
Jakobs, Tobias ;
Bartenstein, Peter ;
Hacker, Marcus .
EUROPEAN JOURNAL OF NUCLEAR MEDICINE AND MOLECULAR IMAGING, 2011, 38 (06) :1037-1045
[7]   Clinical evaluation of the partition model for estimating radiation doses from yttrium-90 microspheres in the treatment of hepatic cancer [J].
S. Ho ;
W. Y. Lau ;
T. W. T. Leung ;
M. Chan ;
P. J. Johnson ;
A. K. C. Li .
European Journal of Nuclear Medicine, 1997, 24 (3) :293-298
[8]   Image-Guided Personalized Predictive Dosimetry by Artery-Specific SPECT/CT Partition Modeling for Safe and Effective 90Y Radioembolization [J].
Kao, Yung Hsiang ;
Tan, Andrew Eik Hock ;
Burgmans, Mark Christiaan ;
Irani, Farah Gillian ;
Khoo, Li Ser ;
Lo, Richard Hoau Gong ;
Tay, Kiang Hiong ;
Tan, Bien Soo ;
Chow, Pierce Kah Hoe ;
Ng, David Chee Eng ;
Goh, Anthony Soon Whatt .
JOURNAL OF NUCLEAR MEDICINE, 2012, 53 (04) :559-566
[9]   Imaging discordance between hepatic angiography versus Tc-99m-MAA SPECT/CT: a case series, technical discussion and clinical implications [J].
Kao, Yung Hsiang ;
Tan, Eik Hock ;
Teo, Terence Kiat Beng ;
Ng, Chee Eng ;
Goh, Soon Whatt .
ANNALS OF NUCLEAR MEDICINE, 2011, 25 (09) :669-676
[10]   A Simple Method for Estimating Dose Delivered to Hepatocellular Carcinoma after Yttrium-90 Glass-Based Radioembolization Therapy: Preliminary Results of a Proof of Concept Study [J].
Kokabi, Nima ;
Galt, James R. ;
Xing, Minzhi ;
Camacho, Juan C. ;
Barron, Bruce J. ;
Schuster, David M. ;
Kim, Hyun S. .
JOURNAL OF VASCULAR AND INTERVENTIONAL RADIOLOGY, 2014, 25 (02) :277-287