The Current Status of Continuous Noninvasive Measurement of Total, Carboxy, and Methemoglobin Concentration

被引:41
作者
Shamir, Micha Y. [1 ]
Avramovich, Aharon [1 ]
Smaka, Todd [1 ]
机构
[1] Univ Miami, Miller Sch Med, Dept Anesthesiol Perioperat Med & Pain Management, Miami, FL 33136 USA
关键词
PULSE CO-OXIMETRY; EMERGENCY-DEPARTMENT; TOTAL HEMOGLOBIN; ACCURACY; MONOXIDE; CARBOXYHEMOGLOBIN; PERFORMANCE; HYPOXIA; MOTION; VOLUME;
D O I
10.1213/ANE.0b013e318233041a
中图分类号
R614 [麻醉学];
学科分类号
100217 ;
摘要
Intraoperative early detection of anemia, identifying toxic levels of carboxyhemoglobin after carbon monoxide exposure and titrating drug dosage to prevent toxic levels of methemoglobin are important goals. The pulse oximeter works by illuminating light into the tissue and sensing the amount of light absorbed. The same methodology is used by laboratory hemoglobinometers to measure hemoglobin concentration. Because both devices work in the same way, efforts were made to modify the pulse codmeter to also measure hemoglobin concentration. Currently there are 2 commercial pulse oximeters (Masimo Rainbow SET and Or Sense NBM-200MP) that measure total hemoglobin concentration and one (Masimo) that also measures methemoglobin and carboxyhemoglobin. In this review, we describe the peer-reviewed literature addressing the accuracy of these monitors. (Anesth Analg 2012;114:972-8)
引用
收藏
页码:972 / 978
页数:7
相关论文
共 46 条
[1]  
American Society of Anesthesiologists, STAND BAS AN MON
[2]   Multiwavelength Pulse Oximetry: Theory for the Future [J].
Aoyagi, Takuo ;
Fuse, Masayoshi ;
Kobayashi, Naoki ;
Machida, Kazuko ;
Miyasaka, Katsuyuki .
ANESTHESIA AND ANALGESIA, 2007, 105 :S53-S58
[3]   Effects of motion on the performance of pulse oximeters in volunteers [J].
Barker, SJ ;
Shah, NK .
ANESTHESIOLOGY, 1996, 85 (04) :774-781
[4]   Measurement of carboxyhemoglobin and methemoglobin by pulse oximetry - A human volunteer study [J].
Barker, Steven J. ;
Curry, Jeremy ;
Redford, Daniel ;
Morgan, Scott .
ANESTHESIOLOGY, 2006, 105 (05) :892-897
[5]   The measurement of dyshemoglobins and total hemoglobin by pulse oximetry [J].
Barker, Steven J. ;
Badal, John J. .
CURRENT OPINION IN ANESTHESIOLOGY, 2008, 21 (06) :805-810
[6]  
Berkow L, 2011, ANESTH ANALG 0929
[7]   COMPARING METHODS OF MEASUREMENT - WHY PLOTTING DIFFERENCE AGAINST STANDARD METHOD IS MISLEADING [J].
BLAND, JM ;
ALTMAN, DG .
LANCET, 1995, 346 (8982) :1085-1087
[8]  
Cannesson M., 2009, F1000 Med Rep, V1, P66
[9]   Validation of noninvasive hemoglobin measurements using the Masimo Radical-7 SpHb Station [J].
Causey, Marlin Wayne ;
Miller, Seth ;
Foster, Andrew ;
Beekley, Alec ;
Zenger, David ;
Martin, Matthew .
AMERICAN JOURNAL OF SURGERY, 2011, 201 (05) :590-596
[10]   Finding needles in a hanystack: A case series of carbon monoxide poisoning detected using new technology in the emergency department [J].
Chee, Kerlen J. ;
Nilson, Douglas ;
Partridge, Robert ;
Hughes, Ashley ;
Suner, Selim ;
Sucov, Andrew ;
Jay, Gregory .
CLINICAL TOXICOLOGY, 2008, 46 (05) :461-469