Removal of Dissolved Oxygen Interference in the Amperometric Detection of Monochloramine Using a pH Control Method

被引:0
|
作者
Seymour, Ian [1 ,2 ]
O'Sullivan, Benjamin [2 ]
Lovera, Pierre [2 ]
Rohan, James F. [1 ]
O'Riordan, Alan [2 ]
机构
[1] Tyndall Natl Inst, Electrochem Mat & Energy Grp, Cork, Ireland
[2] Tyndall Natl Inst, Nanotechnol Grp, Cork, Ireland
来源
2019 IEEE SENSORS | 2019年
基金
爱尔兰科学基金会;
关键词
Monochloramine; Dual electrode sensors; pH; Water quality; In-line sensing; Generator-Collector; Dissolved oxygen; CHLORAMINES; WATER;
D O I
10.1109/sensors43011.2019.8956674
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
Monochloramine amperometric determination was investigated using a pH control method to eliminate dissolved oxygen as an interferent. This method allowed local pH conditions to become more acidic, causing the production of dichloramine. This species showed an onset of electro-reduction at 450 mV, far outside of the oxygen reduction region. Monochloramine was calibrated using this method and showed good linearity (0.99) and a limit of detection of 0.03 ppm.
引用
收藏
页数:4
相关论文
共 50 条
  • [1] Elimination of Oxygen Interference in the Electrochemical Detection of Monochloramine, Using In Situ pH Control at Interdigitated Electrodes
    Seymour, Ian
    O'Sullivan, Benjamin
    Lovera, Pierre
    Rohan, James F.
    O'Riordan, Alan
    ACS SENSORS, 2021, 6 (03): : 1030 - 1038
  • [2] Monochloramine-sensitive amperometric microelectrode: optimization of gold, platinum, and carbon fiber sensing materials for removal of dissolved oxygen interference
    Lee, Woo Hyoung
    Wahman, David. G.
    Pressman, Jonathan. G.
    IONICS, 2015, 21 (09) : 2663 - 2674
  • [3] Monochloramine-sensitive amperometric microelectrode: optimization of gold, platinum, and carbon fiber sensing materials for removal of dissolved oxygen interference
    Woo Hyoung Lee
    David. G. Wahman
    Jonathan. G. Pressman
    Ionics, 2015, 21 : 2663 - 2674
  • [4] Using dissolved oxygen, oxidation reduction potential and pH value for control nitrogen removal in SBR process
    Gao, J.F.
    Peng, Y.Z.
    Wang, S.Y.
    Zeng, W.
    Sui, M.H.
    Zhongguo Jishui Paishui/China Water & Wastewater, 2001, 17 (04):
  • [5] Removal of nitrite interference in the Winkler determination of dissolved oxygen in seawater
    Wong, George T. F.
    MARINE CHEMISTRY, 2012, 130 : 28 - 32
  • [6] Simultaneous control of pH and dissolved oxygen in closed photobioreactor
    Titica, Mariana
    Ifrim, George
    Barbu, Marian
    Kazbar, Antoinette
    Marec, Helene
    Caraman, Sergiu
    Pruvost, Jeremy
    2018 22ND INTERNATIONAL CONFERENCE ON SYSTEM THEORY, CONTROL AND COMPUTING (ICSTCC), 2018, : 372 - 378
  • [7] Iron electrocoagulation for removal of dissolved selenium: Impact of oxygen level and pH
    Bae, Yeunook
    Crompton, Nyssa
    Catalano, Jeffrey
    Giammar, Daniel
    ABSTRACTS OF PAPERS OF THE AMERICAN CHEMICAL SOCIETY, 2017, 253
  • [8] pH, dissolved oxygen, and adsorption effects on metal removal in anaerobic bioreactors
    Willow, MA
    Cohen, RRH
    JOURNAL OF ENVIRONMENTAL QUALITY, 2003, 32 (04) : 1212 - 1221
  • [9] Versatile common instrumentation for optical detection of pH and dissolved oxygen
    Sardesai, Neha
    Rao, Govind
    Kostov, Yordan
    REVIEW OF SCIENTIFIC INSTRUMENTS, 2015, 86 (07):
  • [10] Dissolved oxygen removal from aqueous media by the chromatomembrane method
    Moskvin, LN
    Rodinkov, OV
    Katruzov, AN
    Grigorev, GL
    KhromovBorisov, SN