Vascular smooth muscle contractility depends on cell shape

被引:106
作者
Alford, Patrick W. [1 ]
Nesmith, Alexander P. [1 ]
Seywerd, Johannes N. [1 ]
Grosberg, Anna [1 ]
Parker, Kevin Kit [1 ]
机构
[1] Harvard Univ, Dis Biophys Grp, Harvard Stem Cell Inst, Wyss Inst Biol Inspired Engn,Sch Engn & Appl Sci, Cambridge, MA 02138 USA
基金
美国国家科学基金会;
关键词
EXTRACELLULAR-MATRIX; PHENOTYPIC PROPERTIES; CARDIAC MYOCYTES; GROWTH; MODEL; CYTOSKELETAL; FIBRONECTIN; MODULATION; EXPRESSION; INTEGRINS;
D O I
10.1039/c1ib00061f
中图分类号
Q2 [细胞生物学];
学科分类号
071009 ; 090102 ;
摘要
The physiologic role of smooth muscle structure in defining arterial function is poorly understood. We aimed to elucidate the relationship between vascular smooth muscle architecture and functional contractile output. Using microcontact printing and muscular thin film technology, we engineered in vitro vascular tissues with strictly defined geometries and tested their contractile function. In all tissues, vascular smooth muscle cells (VSMCs) were highly aligned with in vivo-like spindle architecture, and contracted physiologically in response to stimulation with endothelin-1. However, tissues wherein the VSMCs were forced into exaggerated spindle elongation exerted significantly greater contraction force per unit cross-sectional area than those with smaller aspect ratios. Moreover, this increased contraction did not occur in conjunction with an increase in traditionally measured contractile phenotype markers. These results suggest that cellular architecture within vascular tissues plays a significant role in conferring tissue function and that, in some systems, traditional phenotype characterization is not sufficient to define a functionally contractile population of VSMCs.
引用
收藏
页码:1063 / 1070
页数:8
相关论文
共 56 条
  • [1] Computational study of growth and remodelling in the aortic arch
    Alford, Patrick W.
    Taber, Larry A.
    [J]. COMPUTER METHODS IN BIOMECHANICS AND BIOMEDICAL ENGINEERING, 2008, 11 (05) : 525 - 538
  • [2] Growth and remodeling in a thick-walled artery model: effects of spatial variations in wall constituents
    Alford, Patrick W.
    Humphrey, Jay D.
    Taber, Larry A.
    [J]. BIOMECHANICS AND MODELING IN MECHANOBIOLOGY, 2008, 7 (04) : 245 - 262
  • [3] Blast-induced phenotypic switching in cerebral vasospasm
    Alford, Patrick W.
    Dabiri, Borna E.
    Goss, Josue A.
    Hemphill, Matthew A.
    Brigham, Mark D.
    Parker, Kevin Kit
    [J]. PROCEEDINGS OF THE NATIONAL ACADEMY OF SCIENCES OF THE UNITED STATES OF AMERICA, 2011, 108 (31) : 12705 - 12710
  • [4] Biohybrid thin films for measuring contractility in engineered cardiovascular muscle
    Alford, Patrick W.
    Feinberg, Adam W.
    Sheehy, Sean P.
    Parker, Kevin K.
    [J]. BIOMATERIALS, 2010, 31 (13) : 3613 - 3621
  • [5] Sarcomere alignment is regulated by myocyte shape
    Bray, Mark-Anthony
    Sheehy, Sean P.
    Parker, Kevin Kit
    [J]. CELL MOTILITY AND THE CYTOSKELETON, 2008, 65 (08): : 641 - 651
  • [6] Nuclear morphology and deformation in engineered cardiac myocytes and tissues
    Bray, Mark-Anthony P.
    Adams, William J.
    Geisse, Nicholas A.
    Feinberg, Adam W.
    Sheehy, Sean P.
    Parker, Kevin K.
    [J]. BIOMATERIALS, 2010, 31 (19) : 5143 - 5150
  • [7] Cardiomyocyte cultures with controlled macroscopic anisotropy - A model for functional electrophysiological studies of cardiac muscle
    Bursac, N
    Parker, KK
    Iravanian, S
    Tung, L
    [J]. CIRCULATION RESEARCH, 2002, 91 (12) : E45 - E54
  • [8] Regulating orientation and phenotype of primary vascular smooth muscle cells by biodegradable films patterned with arrays of microchannels and discontinuous microwalls
    Cao, Ye
    Poon, Yin Fun
    Feng, Jie
    Rayatpisheh, Shahrzad
    Chan, Vincent
    Chan-Park, Mary B.
    [J]. BIOMATERIALS, 2010, 31 (24) : 6228 - 6238
  • [9] Geometric control of cell life and death
    Chen, CS
    Mrksich, M
    Huang, S
    Whitesides, GM
    Ingber, DE
    [J]. SCIENCE, 1997, 276 (5317) : 1425 - 1428
  • [10] The ideal small arterial substitute: a search for the Holy Grail?
    Conte, MS
    [J]. FASEB JOURNAL, 1998, 12 (01) : 43 - 45