Injectable Colloidal Gold for Use in Intrafractional 2D Image-Guided Radiation Therapy

被引:26
作者
Jolck, Rasmus I. [1 ]
Rydhog, Jonas S. [2 ,3 ]
Christensen, Anders N. [4 ]
Hansen, Anders E. [1 ]
Bruun, Linda M. [1 ]
Schaarup-Jensen, Henrik [5 ]
von Wenck, Asger Stevner [6 ]
Borresen, Betina [6 ]
Kristensen, Annemarie T. [6 ]
Clausen, Mads H. [5 ]
Kjaer, Andreas [7 ,8 ,9 ,10 ]
Conradsen, Knut [4 ]
Larsen, Rasmus [4 ]
af Rosenschold, Per Munck [2 ,3 ]
Andresen, Thomas L. [1 ]
机构
[1] Tech Univ Denmark, Ctr Nanomed & Theranost, Dept Micro & Nanotechnol, DTU Nanotech, DK-2800 Lyngby, Denmark
[2] Rigshosp, Dept Oncol, Sect Radiotherapy 3994, DK-2100 Copenhagen, Denmark
[3] Univ Copenhagen, Niels Bohr Inst, DK-2100 Copenhagen, Denmark
[4] Tech Univ Denmark, Dept Appl Math & Comp Sci, DTU Compute, DK-2800 Lyngby, Denmark
[5] Tech Univ Denmark, Ctr Nanomed & Theranost, Dept Chem, DTU Chem, DK-2800 Lyngby, Denmark
[6] Univ Copenhagen, Fac Hlth & Med Sci, Dept Vet Clin & Anim Sci, DK-1870 Frederiksberg C, Denmark
[7] Rigshosp, Dept Clin Physiol Nucl Med, DK-2100 Copenhagen, Denmark
[8] Rigshosp, PET, DK-2100 Copenhagen, Denmark
[9] Rigshosp, Cluster Mol Imaging, DK-2100 Copenhagen, Denmark
[10] Univ Copenhagen, DK-2100 Copenhagen, Denmark
关键词
SUCROSE ACETATE ISOBUTYRATE; IMPLANTED FIDUCIAL MARKERS; COMPUTED-TOMOGRAPHY; TUMOR MOTION; RADIOTHERAPY; CANCER; LUNG; TRACKING; COMPLICATIONS; NANOPARTICLES;
D O I
10.1002/adhm.201400651
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
In the western world, approximately 50% of all cancer patients receive radiotherapy alone or in combination with surgery or chemotherapy. Image-guided radiotherapy (IGRT) has in recent years been introduced to enhance precision of the delivery of radiation dose to tumor tissue. Fiducial markers are often inserted inside the tumor to improve IGRT precision and to enable monitoring of the tumor position during radiation therapy. In the present article, a liquid fiducial tissue marker is presented, which can be injected into tumor tissue using thin and flexible needles. The liquid fiducial has high radio-opacity, which allows for marker-based image guidance in 2D and 3D X-ray imaging during radiation therapy. This is achieved by surface-engineering gold nanoparticles to be highly compatible with a carbohydrate-based gelation matrix. The new fiducial marker is investigated in mice where they are highly biocompatible and stable after implantation. To investigate the clinical potential, a study is conducted in a canine cancer patient with spontaneous developed solid tumor in which the marker is successfully injected and used to align and image-guide radiation treatment of the canine patient. It is concluded that the new fiducial marker has highly interesting properties that warrant investigations in cancer patients.
引用
收藏
页码:856 / 863
页数:8
相关论文
共 38 条
[1]   Facile conversion of O-silyl protected sugars into their corresponding formates using POCl3 • DMF complex [J].
Andrade, MM ;
Barros, MT .
TETRAHEDRON, 2004, 60 (41) :9235-9243
[2]   Cancer and Radiation Therapy: Current Advances and Future Directions [J].
Baskar, Rajamanickam ;
Lee, Kuo Ann ;
Yeo, Richard ;
Yeoh, Kheng-Wei .
INTERNATIONAL JOURNAL OF MEDICAL SCIENCES, 2012, 9 (03) :193-199
[3]   Complications Associated with the Percutaneous Insertion of Fiducial Markers in the Thorax [J].
Bhagat, Nikhil ;
Fidelman, Nicholas ;
Durack, Jeremy C. ;
Collins, Jeremy ;
Gordon, Roy L. ;
LaBerge, Jeanne M. ;
Kerlan, Robert K., Jr. .
CARDIOVASCULAR AND INTERVENTIONAL RADIOLOGY, 2010, 33 (06) :1186-1191
[4]   SYNTHESIS OF THIOL-DERIVATIZED GOLD NANOPARTICLES IN A 2-PHASE LIQUID-LIQUID SYSTEM [J].
BRUST, M ;
WALKER, M ;
BETHELL, D ;
SCHIFFRIN, DJ ;
WHYMAN, R .
JOURNAL OF THE CHEMICAL SOCIETY-CHEMICAL COMMUNICATIONS, 1994, (07) :801-802
[5]   PET-CT for radiotherapy treatment planning and response monitoring in solid tumors [J].
Bussink, Johan ;
Kaanders, Johannes H. A. M. ;
van der Graaf, Winette T. A. ;
Oyen, Wim J. G. .
NATURE REVIEWS CLINICAL ONCOLOGY, 2011, 8 (04) :233-242
[6]   Fiducial markers in prostate for kV imaging: quantification of visibility and optimization of imaging conditions [J].
Chen, Yu ;
O'Connell, John J. ;
Ko, Christine J. ;
Mayer, Rulon R. ;
Belard, Arnaud ;
McDonough, James E. .
PHYSICS IN MEDICINE AND BIOLOGY, 2012, 57 (01) :155-172
[7]   Image-guided radiotherapy: rationale, benefits, and limitations [J].
Dawson, Laura A. ;
Sharpe, Michael B. .
LANCET ONCOLOGY, 2006, 7 (10) :848-858
[8]   Real-time dynamic MLC tracking for inversely optimized arc radiotherapy [J].
Falk, Marianne ;
af Rosenschold, Per Munck ;
Keall, Paul ;
Cattell, Herbert ;
Cho, Byung Chul ;
Poulsen, Per ;
Povzner, Sergey ;
Sawant, Amit ;
Zimmerman, Jens ;
Korreman, Stine .
RADIOTHERAPY AND ONCOLOGY, 2010, 94 (02) :218-223
[9]   DOSIMETRIC IMPACT AND THEORETICAL CLINICAL BENEFITS OF FIDUCIAL MARKERS FOR DOSE ESCALATED PROSTATE CANCER RADIATION TREATMENT [J].
Gauthier, Isabelle ;
Carrier, Jean-Francois ;
Beliveau-Nadeau, Dominic ;
Fortin, Bernard ;
Taussky, Daniel .
INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2009, 74 (04) :1128-1133
[10]   Gold nanoparticles: recent aspects for human toxicology [J].
Gerber, Alexander ;
Bundschuh, Matthias ;
Klingelhofer, Doris ;
Groneberg, David A. .
JOURNAL OF OCCUPATIONAL MEDICINE AND TOXICOLOGY, 2013, 8