Reevaluation of intrapartum fetal monitoring using fetal oximetry: A review

被引:4
|
作者
Uchida, Toshiyuki [1 ]
Kanayama, Naohiro [1 ]
Kawai, Kenta [1 ]
Mukai, Mari [1 ]
Suzuki, Kazunao [1 ]
Itoh, Hiroaki [1 ]
Niwayama, Masatsugu [2 ]
机构
[1] Hamamatsu Univ Sch Med, Dept Obstet & Gynecol, Hamamatsu, Shizuoka, Japan
[2] Shizuoka Univ, Dept Elect & Elect Engn, Hamamatsu, Shizuoka, Japan
基金
日本学术振兴会;
关键词
examiner's mounting probe; fetal monitoring; fetal pulse oximetry; near-infrared spectroscopy; tissue oximetry; TISSUE OXYGEN-SATURATION; PULSE OXIMETRY; CONTROLLED-TRIAL; LABOR; COMPLICATION; ACCURACY; DELIVERY; MULTICENTER; MANAGEMENT; 2ND-STAGE;
D O I
10.1111/jog.13761
中图分类号
R71 [妇产科学];
学科分类号
100211 ;
摘要
Aim Although several studies reported the measurement of fetal oxygen saturation using fetal pulse oximetry (FPO) for evaluation of the fetal intrapartum condition, a systematic review of the seven randomized controlled trials (RCTs) provided no evidence to support FPO for intrapartum fetal monitoring. In the present review, we re-evaluate an overview for the use of FPO and seven RCTs of FPO. Methods Results We reviewed numerous previous reports on FPO and seven RCTs of intrapartum FPO. RCTs were conducted with the main outcome measure being a reduction in the cesarean section rate. The largest trial with 5341 entries failed to show any reduction. The negative result from this RCT may be explained by the use of a different cutoff value for fetal oxygen saturation compared to the other RCT; in addition, there were differences in the indications for cesarean section due to dystocia and in the definition of non-reassuring fetal status (NRFS). An abnormal FPO value, defined as the fetal oxygen saturation value <30% for at least 10 min, is useful for making a diagnosis of fetal acidosis. A newly developed device, an examiner's finger-mounted tissue oximetry, accurately measures tissue oxygen saturation while overcoming the drawbacks of FPO, such as infection risk and slipping off of the sensor during descent of the fetal head. Conclusion FPO (including the new device) with fetal heart rate monitoring in selected cases of NRFS may reduce the cesarean section rate.
引用
收藏
页码:2127 / 2134
页数:8
相关论文
共 50 条
  • [31] Intrapartum management of nonreassuring fetal heart rate patterns:: A randomized controlled trial of fetal pulse oximetry
    Kühnert, M
    Schmidt, S
    AMERICAN JOURNAL OF OBSTETRICS AND GYNECOLOGY, 2004, 191 (06) : 1989 - 1995
  • [32] A multicenter controlled trial of fetal pulse oximetry in the intrapartum management of nonreassuring fetal heart rate patterns
    Garite, TJ
    Dildy, GA
    McNamara, H
    Nageotte, MP
    Boehm, FH
    Dellinger, EH
    Knuppel, RA
    Porreco, RP
    Miller, HS
    Sunderji, S
    Varner, MW
    Swedlow, DB
    AMERICAN JOURNAL OF OBSTETRICS AND GYNECOLOGY, 2000, 183 (05) : 1049 - 1058
  • [33] Intrapartum fetal monitoring: Past, present, and future
    Chez, BF
    Harvey, MG
    Harvey, CJ
    JOURNAL OF PERINATAL & NEONATAL NURSING, 2000, 14 (03) : 1 - 18
  • [34] Fetal pulse oximetry: Clinical practice
    Vardon, D.
    Hors, Y.
    Grossetti, E.
    Creveuil, C.
    Herticoviez, M.
    Dreyfus, M.
    JOURNAL DE GYNECOLOGIE OBSTETRIQUE ET BIOLOGIE DE LA REPRODUCTION, 2008, 37 (07): : 697 - 704
  • [35] ST Analysis of the Fetal Electrocardiogram in Intrapartum Fetal Monitoring A Meta-Analysis
    Becker, Jeroen H.
    Bax, Leon
    Amer-Wahlin, Isis
    Ojala, Kati
    Vayssiere, Christophe
    Westerhuis, Michelle E. M. H.
    Mol, Ben-Willem
    Visser, Gerard H. A.
    Marsal, Karel
    Kwee, Anneke
    Moons, Karel G. M.
    OBSTETRICS AND GYNECOLOGY, 2012, 119 (01) : 145 - 154
  • [36] Trans-abdominal monitoring of fetal arterial blood oxygenation using pulse oximetry
    Zourabian, A
    Siegel, A
    Chance, B
    Rode, M
    Boas, DA
    JOURNAL OF BIOMEDICAL OPTICS, 2000, 5 (04) : 391 - 405
  • [37] Reliability and agreement in intrapartum fetal heart rate monitoring interpretation: A systematic review
    Engelhart, Christina Hernandez
    Brurberg, Kjetil Gundro
    Aanstad, Kristin Jerve
    Pay, Aase Serine Devold
    Kaasen, Anne
    Blix, Ellen
    Vanbelle, Sophie
    ACTA OBSTETRICIA ET GYNECOLOGICA SCANDINAVICA, 2023, 102 (08) : 970 - 985
  • [38] What we have learned about intrapartum fetal monitoring trials in the MFMU Network
    Bloom, Steven L.
    Belfort, Michael
    Saade, George
    SEMINARS IN PERINATOLOGY, 2016, 40 (05) : 307 - 317
  • [39] Review of optical methods for fetal monitoring in utero
    Gunther, Jacqueline E.
    Jayet, Baptiste
    Sekar, Sanathana Konugolu Venkata
    Kainerstorfer, Jana M.
    Andersson-Engels, Stefan
    JOURNAL OF BIOPHOTONICS, 2022, 15 (06)
  • [40] FIGO consensus guidelines on intrapartum fetal monitoring: Cardiotocography