Reevaluation of intrapartum fetal monitoring using fetal oximetry: A review

被引:4
|
作者
Uchida, Toshiyuki [1 ]
Kanayama, Naohiro [1 ]
Kawai, Kenta [1 ]
Mukai, Mari [1 ]
Suzuki, Kazunao [1 ]
Itoh, Hiroaki [1 ]
Niwayama, Masatsugu [2 ]
机构
[1] Hamamatsu Univ Sch Med, Dept Obstet & Gynecol, Hamamatsu, Shizuoka, Japan
[2] Shizuoka Univ, Dept Elect & Elect Engn, Hamamatsu, Shizuoka, Japan
基金
日本学术振兴会;
关键词
examiner's mounting probe; fetal monitoring; fetal pulse oximetry; near-infrared spectroscopy; tissue oximetry; TISSUE OXYGEN-SATURATION; PULSE OXIMETRY; CONTROLLED-TRIAL; LABOR; COMPLICATION; ACCURACY; DELIVERY; MULTICENTER; MANAGEMENT; 2ND-STAGE;
D O I
10.1111/jog.13761
中图分类号
R71 [妇产科学];
学科分类号
100211 ;
摘要
Aim Although several studies reported the measurement of fetal oxygen saturation using fetal pulse oximetry (FPO) for evaluation of the fetal intrapartum condition, a systematic review of the seven randomized controlled trials (RCTs) provided no evidence to support FPO for intrapartum fetal monitoring. In the present review, we re-evaluate an overview for the use of FPO and seven RCTs of FPO. Methods Results We reviewed numerous previous reports on FPO and seven RCTs of intrapartum FPO. RCTs were conducted with the main outcome measure being a reduction in the cesarean section rate. The largest trial with 5341 entries failed to show any reduction. The negative result from this RCT may be explained by the use of a different cutoff value for fetal oxygen saturation compared to the other RCT; in addition, there were differences in the indications for cesarean section due to dystocia and in the definition of non-reassuring fetal status (NRFS). An abnormal FPO value, defined as the fetal oxygen saturation value <30% for at least 10 min, is useful for making a diagnosis of fetal acidosis. A newly developed device, an examiner's finger-mounted tissue oximetry, accurately measures tissue oxygen saturation while overcoming the drawbacks of FPO, such as infection risk and slipping off of the sensor during descent of the fetal head. Conclusion FPO (including the new device) with fetal heart rate monitoring in selected cases of NRFS may reduce the cesarean section rate.
引用
收藏
页码:2127 / 2134
页数:8
相关论文
共 50 条
  • [21] INTRAPARTUM FETAL PULSE OXIMETRY - FETAL OXYGEN-SATURATION TRENDS DURING LABOR AND RELATION TO DELIVERY OUTCOME
    DILDY, GA
    VANDENBERG, PP
    KATZ, M
    CLARK, SL
    JONGSMA, HW
    NIJHUIS, JG
    LOUCKS, CA
    AMERICAN JOURNAL OF OBSTETRICS AND GYNECOLOGY, 1994, 171 (03) : 679 - 684
  • [22] ST analysis for intrapartum fetal monitoring
    Sacco, Adalina
    Muglu, Javaid
    Navaratnarajah, Ramesan
    Hogg, Matthew
    OBSTETRICIAN & GYNAECOLOGIST, 2015, 17 (01) : 4 - 11
  • [23] Intrapartum electronic fetal monitoring and the identification of systemic fetal inflammation
    Aina-Mumuney, Abimbola J.
    Althaus, Janyne E.
    Henderson, Janice L.
    Blakemore, Maggie C.
    Johnson, Elizabeth A.
    Graham, Ernest M.
    JOURNAL OF REPRODUCTIVE MEDICINE, 2007, 52 (09) : 762 - 768
  • [24] Intrapartum surveillance of IUGR fetuses with cardiotocography and fetal pulse oximetry
    Siristatidis, C
    Salamalekis, E
    Vitoratos, N
    Loghis, C
    Salloum, J
    Kassanos, D
    Panayotopoulos, N
    Creatsas, G
    BIOLOGY OF THE NEONATE, 2003, 83 (03): : 162 - 165
  • [25] Intrapartum Fetal Monitoring: Liability and Documentation
    Miller, Lisa
    CLINICAL OBSTETRICS AND GYNECOLOGY, 2011, 54 (01) : 50 - 55
  • [26] Intrapartum fetal heart rate monitoring
    van Geijn, HP
    Gynaecology, Obstetrics, and Reproductive Medicine in Daily Practice, 2005, 1279 : 332 - 337
  • [27] FETAL MONITORING BY PULSE OXIMETRY AND CTG
    MCNAMARA, H
    JOHNSON, N
    JOURNAL OF PERINATAL MEDICINE, 1993, 21 (06) : 475 - 480
  • [28] Intrapartum fetal monitoring:: its basis and current developments
    Rosén, KG
    Luzietti, R
    PRENATAL AND NEONATAL MEDICINE, 2000, 5 (03): : 155 - 168
  • [29] INTRAPARTUM FETAL PULSE OXIMETRY - THE EFFECTS OF MATERNAL HYPEROXIA ON FETAL ARTERIAL OXYGEN-SATURATION
    DILDY, GA
    CLARK, SL
    LOUCKS, CA
    AMERICAN JOURNAL OF OBSTETRICS AND GYNECOLOGY, 1994, 171 (04) : 1120 - 1124
  • [30] Experiences with intrapartum fetal monitoring in the Netherlands: A survey study
    Habraken, Vera
    Spanjers, Merel J. M.
    Van der Woude, Daisy A. A.
    Oei, S. Guid
    Van Laar, Judith O. E. H.
    EUROPEAN JOURNAL OF OBSTETRICS & GYNECOLOGY AND REPRODUCTIVE BIOLOGY, 2022, 278 : 159 - 165