High-performance capillary electrophoretic determination of glutathione in human lymphocytes

被引:0
作者
Raggi, MA
Mandrioli, R
Sabbioni, C
Mongiello, F
Marini, M
Fanali, S
机构
[1] Univ Bologna, Dipartimento Sci Farmaceut, I-40126 Bologna, Italy
[2] Univ Bologna, Ist Istol & Embriol Gen, I-40126 Bologna, Italy
[3] CNR, Ist Cromatog, I-00016 Rome, Italy
关键词
reduced and oxidized glutathione; capillary electrophoresis; human lymphocytes;
D O I
10.1002/(SICI)1520-667X(1998)10:6<503::AID-MCS5>3.3.CO;2-E
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
A high-performance capillary electrophoretic method is described which allows for a sensitive and accurate determination of reduced glutathione (GSH) in human lymphocytes. The method makes use of a fused silica capillary with polyacrylamide coating (total length 27 cm, effective length 20 cm, 75 or 50 mu m i.d.). The detection wavelength is 200 nm. The procedure is very simple: the lymphocyte lysate, after suitable filtration, is diluted 1:1 with pH 7.0 phosphate buffer and Ellman's reagent is subsequently added. This reagent forms a stable adduct with GSH which blocks glutathione into its reduced form and enhances the method sensitivity [limit of detection (LOD) = 5 x 10(-7) M]. Reagent excess does not interfere and thus does not need to be eliminated. The method has the advantage of allowing for a rapid and simultaneous determination of both GSH and its oxidized form, glutathione disulfide (GS,FG), in a complex matrix such as that of human lymphocytes as well as of requiring only small volumes of the sample. (C) 1998 John Wiley & Sons, Inc.
引用
收藏
页码:503 / 509
页数:7
相关论文
共 28 条
[1]   TUNGSTEN SENSOR FOR AMPEROMETRIC DETECTION OF ORGANIC THIOLS AND PROTEINS [J].
ALEXANDER, PW ;
HIDAYAT, A ;
HIBBERT, DB .
ELECTROANALYSIS, 1995, 7 (03) :290-291
[2]   A HIGH-PERFORMANCE LIQUID-CHROMATOGRAPHY METHOD FOR MEASUREMENT OF OXIDIZED GLUTATHIONE IN BIOLOGICAL SAMPLES [J].
ASENSI, M ;
SASTRE, J ;
PALLARDO, FV ;
DELAASUNCION, JG ;
ESTRELA, JM ;
VINA, J .
ANALYTICAL BIOCHEMISTRY, 1994, 217 (02) :323-328
[3]  
Banica FG, 1996, ANAL LETT, V29, P1415
[4]   OXIDATION OF GLUTATHIONE DURING HYDROPEROXIDE METABOLISM - A STUDY USING ISOLATED HEPATOCYTES AND THE GLUTATHIONE-REDUCTASE INHIBITOR 1,3-BIS(2-CHLOROETHYL)-1-NITROSOUREA [J].
EKLOW, L ;
MOLDEUS, P ;
ORRENIUS, S .
EUROPEAN JOURNAL OF BIOCHEMISTRY, 1984, 138 (03) :459-463
[5]  
Ercal N, 1996, BIOMED CHROMATOGR, V10, P15, DOI 10.1002/(SICI)1099-0801(199601)10:1<15::AID-BMC544>3.0.CO
[6]  
2-5
[7]   APOPTOSIS OR NECROSIS - INTRACELLULAR LEVELS OF GLUTATHIONE INFLUENCE MODE OF CELL-DEATH [J].
FERNANDES, RS ;
COTTER, TG .
BIOCHEMICAL PHARMACOLOGY, 1994, 48 (04) :675-681
[8]   HIGH-PERFORMANCE ELECTROPHORESIS - ELIMINATION OF ELECTROENDOSMOSIS AND SOLUTE ADSORPTION [J].
HJERTEN, S .
JOURNAL OF CHROMATOGRAPHY, 1985, 347 (02) :191-198
[9]   A HIGH-PERFORMANCE LIQUID-CHROMATOGRAPHIC ASSAY FOR REDUCED AND OXIDIZED GLUTATHIONE IN BIOLOGICAL SAMPLES [J].
JAYATILLEKE, E ;
SHAW, S .
ANALYTICAL BIOCHEMISTRY, 1993, 214 (02) :452-457
[10]   DETERMINATION OF GLUTATHIONE AND RELATED AMINOTHIOLS BY GAS-CHROMATOGRAPHY WITH FLAME PHOTOMETRIC DETECTION [J].
KATAOKA, H ;
TAKAGI, K ;
MAKITA, M .
BIOMEDICAL CHROMATOGRAPHY, 1995, 9 (02) :85-89