Short tau inversion recovery and proton density-weighted fat suppressed sequences for the evaluation of osteoarthritis of the knee with a 1.0 T dedicated extremity MRI: development of a time-efficient sequence protocol

被引:59
作者
Roemer, FW
Guermazi, A
Lynch, JA
Peterfy, CG
Nevitt, MC
Webb, N
Li, J
Mohr, A
Genant, HK
Felson, DT
机构
[1] Klinikum Augsburg, Dept Radiol, D-86156 Augsburg, Germany
[2] Univ Calif San Francisco, Dept Radiol, Osteoporosis & Arthrit Res Grp, San Francisco, CA 94143 USA
[3] Synarc Inc, San Francisco, CA USA
[4] Univ Calif San Francisco, Dept Epidemiol & Biostat, San Francisco, CA 94143 USA
[5] Univ Alabama, Div Prevent Med, Birmingham, AL USA
[6] Univ Schleswig Holstein, Dept Radiol, Kiel, Germany
[7] Boston Univ, Sch Med, Clin Epidemiol Unit, Boston, MA 02118 USA
关键词
osteoarthritis; MRI; fat suppression; STIR; scoring; pulse sequences; cartilage; bone marrow edema;
D O I
10.1007/s00330-004-2608-6
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Aim of this study was to develop a time-efficient sequence protocol for a 1.0 T dedicated MR system to be used for whole-organ scoring of osteoarthritis (OA). Thirty-four knees were examined using a protocol that included fat suppressed fast spin echo proton density weighted sequences (PDFS) in three planes plus a coronal STIR sequence. Two radiologists scored each knee by consensus for five OA features. In separate sessions, all knees were scored using three different combinations of sequences: (1) all four sequences (reference protocol, 16 min 31 s scanning time), (2) three PDFS sequences without STIR ("No STIR", 12 min 25 s scanning time) and (3) sagittal and axial PDFS sequences plus a coronal STIR sequence ("No PDFS", 11 min 49 s scanning time). Agreement of the readings using both subsets of sequences compared to the reference protocol was evaluated using weighted kappa statistics. K.-coefficients showed good or excellent agreement for both sequence subsets in comparison to the reference protocol for all assessed features. kappa-coefficients for No PDFS/No STIR: bone marrow abnormalities (0.74/0.67), subarticular cysts (0.84/0.63), marginal osteophytes (0.77/0.71), menisci (0.75/0.79), tibial cartilage (0.71/0.78). Optimization of sequence protocols consisting of three sequences results in time savings and cost efficiency in imaging of knee OA without loss of information over a more time consuming protocol.
引用
收藏
页码:978 / 987
页数:10
相关论文
共 16 条
  • [1] Accuracy of T2-weighted fast spin-echo MR imaging with fat saturation in detecting cartilage defects in the knee: Comparison with arthroscopy in 130 patients
    Bredella, MA
    Tirman, PFJ
    Peterfy, CG
    Zarlingo, M
    Feller, JF
    Bost, FW
    Belzer, JP
    Wischer, TK
    Genant, HK
    [J]. AMERICAN JOURNAL OF ROENTGENOLOGY, 1999, 172 (04) : 1073 - 1080
  • [2] STATISTICAL-METHODS FOR ASSESSING OBSERVER VARIABILITY IN CLINICAL MEASURES
    BRENNAN, P
    SILMAN, A
    [J]. BMJ-BRITISH MEDICAL JOURNAL, 1992, 304 (6840): : 1491 - 1494
  • [3] Burgkart R, 2001, ARTHRITIS RHEUM, V44, P2072, DOI 10.1002/1529-0131(200109)44:9<2072::AID-ART357>3.0.CO
  • [4] 2-3
  • [5] Fat suppression in MR imaging: Techniques and pitfalls
    Delfaut, EM
    Beltran, J
    Johnson, G
    Rousseau, J
    Marchandise, X
    Cotten, A
    [J]. RADIOGRAPHICS, 1999, 19 (02) : 373 - 382
  • [6] Quantitative MR imaging evaluation of chondropathy in osteoarthritic knees
    Drapé, JL
    Pessis, E
    Auleley, GR
    Chevrot, A
    Dougados, M
    Ayral, X
    [J]. RADIOLOGY, 1998, 208 (01) : 49 - 55
  • [7] MR findings in knee osteoarthritis
    Guermazi, A
    Zaim, S
    Taouli, B
    Miaux, Y
    Peterfy, CG
    Genant, HK
    [J]. EUROPEAN RADIOLOGY, 2003, 13 (06) : 1370 - 1386
  • [8] Musculoskeletal MRI: dedicated systems
    Masciocchi, C
    Barile, A
    Satragno, L
    [J]. EUROPEAN RADIOLOGY, 2000, 10 (02) : 250 - 255
  • [9] The value of water-excitation 3D FLASH and fat-saturated PDw TSE MR imaging for detecting and grading articular cartilage lesions of the knee
    Mohr, A
    [J]. SKELETAL RADIOLOGY, 2003, 32 (07) : 396 - 402
  • [10] Using fat-saturated proton density-weighted MR imaging to evaluate articular cartilage
    Mohr, A
    Roemer, FW
    Genant, HK
    Liess, C
    [J]. AMERICAN JOURNAL OF ROENTGENOLOGY, 2003, 181 (01) : 280 - 281