Optimization of heat exchanger size of a 10 kW organic Rankine cycle system

被引:5
作者
Jafari, Alireza [1 ]
Yang, Chien-Yuh [1 ]
Chang, Chi-Che [1 ]
机构
[1] Natl Cent Univ, Dept Mech Engn, Taoyuan 32054, Taiwan
来源
4TH INTERNATIONAL SEMINAR ON ORC POWER SYSTEMS | 2017年 / 129卷
关键词
Organic Rankine cycle (ORC); Number of transfer unit (NTU); Thermal efficiency; Evaporator; TEMPERATURE; PERFORMANCE; CONFIGURATIONS; RECOVERY; ENGINE; ORC;
D O I
10.1016/j.egypro.2017.09.203
中图分类号
TE [石油、天然气工业]; TK [能源与动力工程];
学科分类号
0807 ; 0820 ;
摘要
Most of the heat exchangers design in a conventional Rankine cycle power generation system is based on the assumption of a fixed temperature difference between the heat source and the inlet temperature of the expander. Since the temperature difference between the evaporator and the condenser is high, the effect of this estimated temperature difference on the system performance is not important. However, for an ORC system, since the temperature of heat source is low, a minor difference on the temperature estimation will affect the system thermal efficiency significantly. This study provides an experimental measurement of a practical 10 kW organic Rankine cycle system using HFC-245fa as working fluid subject to the influence of heat exchangers with different NTU. The effect of NTU of evaporator on heat transfer rate, network output, system thermal efficiency and investment payback years were studied. The results show that with increasing NTU of evaporator leads to the increase of total heat transfer rate, work output and system thermal efficiency. However, since the system installation cost increases with increasing heat exchangers NTU, in combining with the increase of power output, an optimal heat exchanger NTU for the shortest investment payback years is found. (C) 2017 The Authors. Published by Elsevier Ltd.
引用
收藏
页码:851 / 858
页数:8
相关论文
共 22 条
  • [1] Capehart B.L., 2006, Guide to energy management
  • [2] Analysis and optimization of the low-temperature solar organic Rankine cycle (ORC)
    Delgado-Torres, Agustin M.
    Garcia-Rodriguez, Lourdes
    [J]. ENERGY CONVERSION AND MANAGEMENT, 2010, 51 (12) : 2846 - 2856
  • [3] Effect of off-design heat source temperature on heat transfer characteristics and system performance of a 250-kW organic Rankine cycle system
    Fu, Ben-Ran
    Hsu, Sung-Wei
    Lee, Yuh-Ren
    Hsieh, Jui-Ching
    Chang, Chia-Ming
    Liu, Chih-His
    [J]. APPLIED THERMAL ENGINEERING, 2014, 70 (01) : 7 - 12
  • [4] Selection of working fluids for a novel low-temperature geothermally-powered ORC based cogeneration system
    Guo, T.
    Wang, H. X.
    Zhang, S. J.
    [J]. ENERGY CONVERSION AND MANAGEMENT, 2011, 52 (06) : 2384 - 2391
  • [5] Thermal model validation of plate heat exchangers with generalized configurations
    Gut, JAW
    Fernandes, R
    Pinto, JM
    Tadini, CC
    [J]. CHEMICAL ENGINEERING SCIENCE, 2004, 59 (21) : 4591 - 4600
  • [6] Experiments on the characteristics of evaporation of R410A in brazed plate heat exchangers with different geometric configurations
    Han, DH
    Lee, KJ
    Kim, YH
    [J]. APPLIED THERMAL ENGINEERING, 2003, 23 (10) : 1209 - 1225
  • [7] Optimization of low temperature solar thermal electric generation with Organic Rankine Cycle in different areas
    Jing, Li
    Gang, Pei
    Jie, Ji
    [J]. APPLIED ENERGY, 2010, 87 (11) : 3355 - 3365
  • [8] Multipass Plate Heat Exchangers-Effectiveness-NTU Results and Guidelines for Selecting Pass Arrangements
    Kandlikar, S. G.
    Shah, R. K.
    [J]. JOURNAL OF HEAT TRANSFER-TRANSACTIONS OF THE ASME, 1989, 111 (1-4): : 300 - 313
  • [9] Economic assessment of a two-stage solar organic Rankine cycle for reverse osmosis desalination
    Kosmadakis, G.
    Manolakos, D.
    Kyritsis, S.
    Papadakis, G.
    [J]. RENEWABLE ENERGY, 2009, 34 (06) : 1579 - 1586
  • [10] Lemmon E. W., 2013, NIST STAND REF DATAB