Evaluating efficiency of H2O2 on removal of organic matter from drinking water

被引:39
作者
Dargahi, Abdollah [1 ]
Pirsaheb, Meghdad [2 ]
Hazrati, Sadegh [3 ]
Fazlzadehdavil, Mehdi [3 ]
Khamutian, Razie [4 ]
Amirian, Tahere [4 ]
机构
[1] Islamic Azad Univ, Parsabad Moghan Branch, Young Researchers & Elite Club, Parsabad, Iran
[2] Kermanshah Univ Med Sci, Sch Publ Hlth, Dept Environm Hlth Engn, Kermanshah, Iran
[3] Ardabil Univ Med Sci, Sch Publ Hlth, Dept Environm Hlth Engn, Ardebil, Iran
[4] Kermanshah Univ Med Sci, Dept Environm Hlth Engn, Environm Hlth Songhor City Ctr, Kermanshah, Iran
关键词
Drinking water; Water treatment; H2O2; Organic matter; HYDROGEN-PEROXIDE; OPERATIONAL PARAMETERS; AQUEOUS-SOLUTION; UV/H2O2; DEGRADATION; KINETICS; SOILS;
D O I
10.1080/19443994.2014.889608
中图分类号
TQ [化学工业];
学科分类号
0817 ;
摘要
H2O2 has been widely used because of intensified pollution of water resources like rivers, lakes, and dams to organic matters and formation of carcinogenic disinfection by-products (DBPs). This study aimed at evaluating the rate of organic matter removal from drinking water by H2O2. Water samples were taken from Gharasoo River and effluent of wastewater treatment plant in Farabi hospital. Samples containing humus organic matters (A, B, C, and D) as well as pesticides including Diazinon and 2,4-dichlorophenoxy-acetic acid (2,4-D) were also prepared. Measurements were performed using a spectrophotometer at a wavelength of 253.7 nm. COD decreased as the concentration of H2O2 increased in all the samples and maximum removal was observed at the concentration of 10 mg/l of H2O2. In the samples containing humus, COD removal rates were also increased by increasing hydrogen peroxide doses with the highest removal rates of 81, 70.9, 65.21, and 62.85% observed for humus A, B, C, and D, respectively. The lowest absorption rate occurred at neutral pH and high correlation coefficient (i.e. R-2 = 0.92) which was observed between COD removal and absorption rates of organic matter for all the samples. According to the results, it can be concluded that H2O2 is an appropriate oxidant for the removal of organic matter from drinking water. On the other hand, COD due to these materials can be estimated through measuring their absorption rates.
引用
收藏
页码:1589 / 1593
页数:5
相关论文
共 29 条
[1]   The effect of operational parameters on UV/H2O2 decolourisation of Acid Blue 74 [J].
Aleboyeh, A ;
Moussa, Y ;
Aleboyeh, H .
DYES AND PIGMENTS, 2005, 66 (02) :129-134
[2]  
Amin H, 2008, PHYSICOCHEM PROBL MI, V42, P17
[3]  
[Anonymous], 1978, CHEM ENV ENG
[4]  
[Anonymous], STANDARD METHODS EXA
[5]  
[Anonymous], 1990, WATER QUALITY TREATM
[6]  
ASCE AWWA, 1990, WAT TREATM PLANT DES
[7]  
AWWA, 1996, WAT TREATM PLANT DES, V255
[8]   CRITICAL-REVIEW OF RATE CONSTANTS FOR REACTIONS OF HYDRATED ELECTRONS, HYDROGEN-ATOMS AND HYDROXYL RADICALS (.OH/.O-) IN AQUEOUS-SOLUTION [J].
BUXTON, GV ;
GREENSTOCK, CL ;
HELMAN, WP ;
ROSS, AB .
JOURNAL OF PHYSICAL AND CHEMICAL REFERENCE DATA, 1988, 17 (02) :513-886
[9]   Modeling the quantum yields of herbicide 2,4-D decay in UV/H2O2 process [J].
Chu, W .
CHEMOSPHERE, 2001, 44 (05) :935-941
[10]  
Cotruvo J., 1999, PROVIDING SAFE DRINK, P247